Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Mitsubishi NF630-CW 3P 600A Molded Case Circuit Breaker
    ❤ Add to collection
  • Mitsubishi NF630-CW 3P 600A Molded Case Circuit Breaker

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥43423.00
      ¥46543.00
      ¥43423.00
      ¥43423.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:22.450KG
    • Quantity:
    • (Inventory: 6346)
Description
<span style="font-size: 18px; font-family: arial;">Mitsubishi NF630-CW 3P 600A Molded Case Circuit Breaker</span>

Mitsubishi NF630-CW Molded Case Circuit Breaker

The Mitsubishi NF630-CW is a 3-pole molded case circuit breaker MCCB from the WS-V series NF-C economy class. This device provides overcurrent and short-circuit protection for electrical distribution systems and equipment. With a rated current of 600 amperes and frame size of 630 amperes, this breaker is suitable for incoming power protection, feeder circuits, and motor branch circuit protection in industrial and commercial electrical installations.

Electrical Ratings

Poles configuration: 3-pole 3P. Rated current: 600 A. Trip current rating: 600 AT. Frame current rating: 600 AF. Rated impulse withstand voltage Uimp: 8 kV. Rated insulation voltage Ui: 690 V AC. Rated operational voltage: up to 690 V AC for appropriate applications. The breaker is designed for AC systems at 50 Hz or 60 Hz operating frequency.

Breaking Capacity

Ultimate short-circuit breaking capacity Icu varies with system voltage. At 400 V AC, Icu is 36 kA per IEC 60947-2. At 200-230 V AC, Icu is 50 kA. At 380 V AC, Icu is 40 kA. At 415 V AC, Icu is 36 kA. At 440 V AC, Icu is 36 kA. At 500 V AC, Icu is 18 kA. For DC applications, Icu is 20 kA at 250 V DC. Service short-circuit breaking capacity Ics is 18 kA at 400 V AC, representing 50 percent of Icu. The breaking performance meets IEC 60947-2 standards for industrial circuit protection.


Protection Functions

Trip unit type: thermal-magnetic with fixed settings. Thermal protection provides overload protection with inverse time characteristic, tripping threshold fixed at 600 A. The thermal element responds to sustained overcurrent conditions typical of equipment overloads. Magnetic protection provides instantaneous short-circuit protection. The magnetic trip responds to high-magnitude fault currents to rapidly interrupt short-circuit conditions. The fixed trip settings simplify installation and ensure consistent protection performance without adjustment requirements.

Mechanical Specifications

Dimensions: Width 140 mm x Height 257 mm x Depth 134 mm. Electrical durability with load at 440 V AC: 1000 operations. Mechanical durability at no load: 6000 operations. Connection type: front lugs or bars connection suitable for panel wiring and busbar systems. Installation category A utilization category. The compact frame size facilitates installation in standard distribution panels and motor control centers.

Standards and Approvals

CE marked for European market compliance with Low Voltage Directive. Marine use approvals include Nippon Kaiji Kyokai NK, Lloyd Register LR, American Bureau of Shipping ABS, and Germanischer Lloyd GL. Degree of pollution rating 3 for industrial environments. IEC 60947-2 and EN 60947-2 compliance ensures international acceptance. The breaker is certified for use in electrical systems requiring compliance with global industrial standards.

Protection Applications

The NF630-CW provides overload and short-circuit protection for electrical circuits, protecting wiring and power distribution equipment from damage. For short-circuit-only protection where standard thermal-magnetic characteristics are not required, a dedicated short-circuit protective version without overcurrent trip is available in this product series for special applications requiring only instantaneous trip functionality.

WS-V Series Technology

The WS-V series incorporates new cutoff technology to enhance interrupting performance while maintaining compact dimensions. This series is designed to respond to individual market needs for power receiving, distribution, and machinery applications. The breaker is compatible with the latest standards of various countries to deliver optimal performance based on specific installation requirements. The design balances economical pricing with reliable protective function.

Installation Considerations

Front connection terminals accept lugs or bars for wiring flexibility. The breaker mounts in standard panel cutouts and accepts busbar connections for distribution assemblies. Operating mechanism supports manual switching and accommodates optional accessories including shunt trips, auxiliary contacts, and under-voltage releases for enhanced control and monitoring functions.


GE F35 PLC Module 
CON021/913-040+PR6424/000-000 EPRO Module

GE L90E00VKHF8LH6AL6ENXXR7C PLC Module 
BACHMANN WT205V PLC Module
YOKOGAWA VF311 PCB Board
PR9350/02 EMERSON 
PR6423/10R-131+CON031 EMERSON 
A6110 EMERSON Shaft Relative Vibrati Monitor Module
Honeywell 8C-TAIDB1 51307133-175 PLC Module
GE 369B1869G0003 PLC Module
YOKOGAWA AFV30D-S41251 S2 PLC Module 
CON041+PR6423/004-030-CN EPRO Module 
CON041+PR6423/004-031-CN EPRO Module
GE DS200IMCPG1CGC PLC Module
YOKOGAWA YCB301-C400 PLC Cable 
IS200SDIIH1A Contact Input Isolation Terminal Board
TRICONEX UMK-SE11,25-1 PLC Module
TRICONEX 3007 PLC Module
TRICONEX 4327 
IS215VCMIH2B GE Mark VI Printed Circuit Board 
GE SR369 369-HI-0-0-0-0-H-E PLC Module
GE L30-N00-VUH-F8L-H6L-LXX-NXX-R7C PLC Module
EPRO PR6426/010-000/CON021/916-120 PLC Module
1900/65A 167669-02 172323-01 Bently Nevada
YOKOGAWA NFBU200-S01 PLC Module
WOODWARD LQ6 PLC Module 
Honeywell 51403698-100 PLC Board Module 
TRICONEX 3603E PLC Module 
TRICONEX 3617E PLC Module
YOKOGAWA NFBU200 PLC Module
  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials