Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Omron NS5-SQ00B-V2 HMI Touch Screen 5.7 Inch
    ❤ Add to collection
  • Omron NS5-SQ00B-V2 HMI Touch Screen 5.7 Inch

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42862.00
      ¥43563.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:10.500KG
    • Quantity:
    • (Inventory: 5286)
Description
<span style="font-size: 18px; font-family: arial;">Omron NS5-SQ00B-V2 HMI Touch Screen 5.7 Inch</span>

Omron NS5-SQ00B-V2 HMI Operator Interface

The Omron NS5-SQ00B-V2 is a 5.7-inch graphic operator interface (HMI) from the NS series, engineered for efficient and user‑friendly interaction in industrial automation systems. It features a high‑brightness TFT color LCD display with 256 colors and a resolution of 320 × 240 pixels (QVGA). The resistive analog touch panel supports glove operation and provides reliable tactile feedback. The NS5-SQ00B-V2 includes 60 MB of memory, RS‑232C and RS‑422A/485 communication ports, and operates on a 24 V DC power supply. The front panel is rated IP65, providing protection against dust and water jets. This HMI is suitable for machine control, production line monitoring, and data display applications in factory automation.

Technical Specifications

Display size: 5.7 inches diagonal. Display type: TFT color LCD. Display colors: 256 colors. Resolution: 320 × 240 pixels (QVGA). Backlight: LED backlight (replaceable). Touch panel: analog resistive. Memory: 60 MB standard. Communication ports: RS-232C and RS-422A/485 (supports Host Link, Modbus RTU, and other protocols). Power supply: 24 V DC ±15% (20.4‑27.6 V). Power consumption: 15 W maximum. Operating temperature: 0°C to 50°C. Storage: -20°C to 60°C. Humidity: 35% to 85% (non‑condensing). Front panel protection: IP65 (dust‑tight and water‑jet resistant). Dimensions: approximately 142 mm (W) × 98 mm (H) × 56 mm (D). Weight: approximately 500 g. Development environment: Omron CX‑One with NS‑Designer (CX‑Designer). The panel supports multi‑language switching up to 42 languages.

Key Features

  • 5.7-inch TFT color LCD with high brightness LED backlight

  • QVGA resolution (320 × 240 pixels) with 256 display colors

  • Analog resistive touch panel supports gloved operation

  • 60 MB memory for screen storage and data logging

  • RS-232C and RS-422A/485 communication ports

  • 24 V DC power supply (±15% tolerance)

  • IP65 front panel protection (dust-tight, water-resistant)

  • Supports up to 42 languages with runtime switching

  • Development environment via CX-Designer (part of CX-One)

  • Built-in troubleshooting program SAP library


Programming and Software

The NS5-SQ00B-V2 is programmed using Omron CX‑Designer (part of the CX‑One software suite). The software supports screen creation, alarm management, trend graphs, data logging, and recipe functions. It includes a library of pre‑configured objects and drivers for major PLC brands. Multi‑language support allows runtime switching between up to 42 languages, facilitating use in international facilities. The screen design can be accomplished with minimal programming effort using the intuitive development environment. The panel also integrates a built‑in troubleshooting program SAP library, providing simple explanations and solutions for error causes.

Communication and Connectivity

The NS5-SQ00B-V2 offers RS‑232C and RS‑422A/485 serial ports, enabling connection to a wide range of PLCs, controllers, and other serial devices. Supported protocols include Omron Host Link, Modbus RTU, and others. The RS‑422A/485 port supports multi‑drop configurations for connecting multiple devices. The panel integrates an FA integration toolkit that supports seamless connection with mainstream PLCs and Omron frequency converters, making it suitable for efficient human‑machine interaction and monitoring needs of small and medium‑sized automation equipment. The panel does not include Ethernet as standard; for networked applications, other NS series models with Ethernet are available.

Applications

The NS5-SQ00B-V2 is used in industrial automation applications such as small to medium packaging machines, conveyor controls, assembly line monitoring, HVAC control panels, and test equipment HMIs. Its compact 5.7-inch size is ideal for installations where panel space is limited but operator visibility is still required. The IP65 front protection allows installation in wash‑down environments such as food and beverage production. Typical industries include factory automation, pharmaceutical manufacturing, automotive parts assembly, and general industrial machinery.

Installation and Wiring

The NS5-SQ00B-V2 is designed for panel mounting using the supplied mounting brackets. The required panel cutout is approximately 142 mm × 98 mm. Ensure a proper seal between the panel and the HMI gasket to maintain IP65 protection. Connect 24 V DC power to the power terminals (positive and negative). Connect the PLC to the RS‑232C or RS‑422A/485 port using a shielded serial cable. The panel includes a USB host port for data transfer and screen capture (depending on the specific model variant). The rear of the unit includes a DIP switch for communication port configuration. Ground the panel to the cabinet ground.


Maintenance and Diagnostics

The NS5-SQ00B-V2 includes front LED indicators for power and communication status. The built‑in troubleshooting program SAP library aids in diagnosing errors by providing simple explanations and solutions. The LED backlight is replaceable, extending the service life of the panel. If the screen becomes dim, replace the backlight. Clean the touch screen with a soft, damp cloth. Do not use solvents or abrasive cleaners. The internal battery (for real‑time clock) should be replaced every 5 years. The panel stores diagnostic information accessible via the configuration software.

Environmental and Compliance

The NS5-SQ00B-V2 is CE, UL, and CSA certified. It is RoHS compliant. Operating temperature: 0°C to 50°C. Storage: -20°C to 60°C. Humidity: 35‑85% non‑condensing. The front panel is IP65 rated; the rear requires installation in a control cabinet. Vibration resistance: 2g (10‑55 Hz).

Conclusion

The Omron NS5-SQ00B-V2 HMI provides a compact, cost‑effective operator interface for small to medium automation systems. Its 5.7-inch TFT color display, 60 MB memory, and multi‑language support make it suitable for applications requiring reliable operator interaction without the complexity or cost of larger HMIs.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting
  • ADLINK PCIe-GIE72/74 Image Acquisition Card Deployment Guide
  • ADLINK PCIe-7856/7853 Sports I/O Controller Card Guide
  • ADLINK PCI-6308 Isolation Output Card Programming and Installation
  • ADLINK PCI-7432 installation and configuration troubleshooting
  • adlink nupro-e72 التحكم الصناعي اللوحة
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit