Product Overview
The National Instruments PXI-6289 is a multifunction data acquisition card for PXI systems. It belongs to the NI M Series DAQ family and provides 32 analog input channels with 18 bit resolution and a maximum single channel sampling rate of 625 kS/s. The card also includes four analog output channels, 48 digital input and output lines, and two counters.
The PXI-6289 installs in a compatible PXI slot and is supported by NI-DAQmx software. Its high channel count and 18 bit resolution make it suitable for automated test, laboratory measurement, and industrial monitoring where fine measurement detail is required across many channels.
High Resolution Analog Input
The card provides 32 analog input channels with 18 bit resolution and a maximum single channel rate of 625 kS/s, with the aggregate rate shared across active channels. Selectable input ranges allow the card to match different signal levels and use the available resolution effectively.
Hardware timed acquisition, external sample clocks, and triggering support repeatable measurement sequences. Multichannel scanning can be configured for single ended or differential connections depending on the accessory and wiring. Differential wiring is often preferred for low level signals and for rejecting common mode noise.
Analog Output and Digital I/O
The card includes four 16 bit analog output channels for control voltages, setpoints, and waveform generation. Hardware timed output produces deterministic waveform sequences, which is useful for stimulus response testing and control loop evaluation.
Forty eight digital lines provide logic level control, relay driving through external conditioning, and status monitoring. Two 32 bit counters support event counting, frequency measurement, pulse generation, and encoder position tracking.
Timing and PXI Integration
NI-DAQmx provides start triggers, reference triggers, pause triggers, and sample clock configuration for the PXI-6289. Within a PXI chassis, the card can share trigger lines and clocks with other instruments, enabling coordinated multi instrument test sequences.
Engineers should document the clock source and trigger routing so that the test sequence can be reproduced. For systems that require more channels, additional cards or devices can be synchronized where the architecture supports shared timing.
Software and Accessories
The PXI-6289 is supported by NI-DAQmx and can be programmed with LabVIEW, LabWindows/CVI, Measurement Studio, and other NI-DAQmx compatible environments. The driver handles channel configuration, scaling, calibration metadata, and task management.
Installation requires a compatible PXI slot with adequate airflow and a chassis within the supported specifications. Cables should be routed away from power switching equipment, and shields should be terminated according to the accessory documentation.
Typical Applications
High channel count analog data acquisition
Precision sensor and transducer measurement
Mixed signal automated test systems
Waveform generation and stimulus response test
Digital control and event counting
PXI based test and measurement systems
The PXI-6289 provides 32 analog inputs at 18 bit resolution, 4 analog outputs, 48 digital lines, and 2 counters in an M Series PXI card. Its resolution, channel count, and NI-DAQmx support make it suitable for demanding measurement applications.