Product Overview
The National Instruments SCB-68 is a shielded connector block for 68 pin data acquisition devices. It provides screw terminal connections for field wiring and a prototyping area where simple signal conditioning circuits can be assembled. The block is used with compatible NI DAQ cards and USB devices to connect sensors and signals to the DAQ hardware.
The SCB-68 is part of the NI accessory family for data acquisition. It is used in laboratories, test benches, and industrial applications where a robust and organized wiring interface is needed. The shielded enclosure helps reduce electromagnetic interference on low level signals.
Screw Terminal Connections
The connector block provides screw terminals for each signal, which allows individual wires to be connected securely. Engineers should confirm the pin mapping between the connector block and the DAQ device before wiring, because incorrect mapping can damage the device or produce invalid measurements.
Labeling each terminal and cable simplifies maintenance and troubleshooting. In systems with many signals, a clear wiring diagram helps during commissioning and when the system is modified. Engineers should use wire sizes and strip lengths within the block specifications.
Prototyping Area
The SCB-68 includes a prototyping area where simple circuits can be assembled, such as voltage dividers, filters, and current sensing resistors. This allows sensor signals to be conditioned before they reach the DAQ device. Engineers should verify that the added circuitry is compatible with the input ranges and impedance requirements of the DAQ hardware.
The prototyping area should be used with care, because errors in the added circuitry can affect measurement accuracy or damage the DAQ device. Engineers should document any conditioning circuits and verify performance with known signals.
Shielding and Signal Integrity
The shielded enclosure of the SCB-68 helps reduce noise pickup on signal wiring, which is important for low level analog measurements. Engineers should connect the shield according to the documentation and should avoid ground loops when routing cables.
Signal wiring should be separated from power conductors and routed away from high current switching equipment. Twisted pair wiring for differential signals improves noise rejection. These practices help maintain measurement quality in electrically noisy environments.
Compatibility and Installation
The SCB-68 is compatible with specific NI DAQ devices that use 68 pin connectors. Engineers should confirm the supported devices and cable types before using the block. The block connects to the DAQ device through a shielded cable, which should be routed to avoid strain and interference.
The block should be placed on a stable surface with access for wiring and inspection. Engineers should verify that the assembly is secure and that cables are not under tension. Regular inspection of terminal tightness and cable condition helps maintain reliable connections.
Typical Applications
Sensor and signal connection to 68 pin DAQ devices
Low level analog measurement with shielding
Bench top prototyping of signal conditioning
Laboratory and industrial DAQ systems
Test fixtures with many analog and digital signals
Educational measurement setups