The National Instruments SCXI-1160 is a relay output module for SCXI signal conditioning systems. It provides isolated single pole double throw relay channels for switching external circuits under software control. The module is used in automated test, signal routing, load control, and industrial validation systems where isolated switching is required.
SCXI systems condition and route signals before they reach a DAQ device. The SCXI-1160 adds relay output capability to this architecture. Relay switching provides galvanic isolation between the control system and the switched circuit, which helps protect the DAQ hardware from transients and ground potential differences.
SPDT Relay Channels
The module provides multiple single pole double throw relay channels. Each channel can connect a common terminal to one of two positions, which supports signal routing that requires selection between two paths as well as simple on and off switching.
Engineers should verify voltage, current, and load type before connection. Inductive loads may require external suppression such as flyback diodes to protect relay contacts. Channel grouping and documentation help maintenance.
Isolation and Load Compatibility
Relay contacts provide isolation between the control system and the switched circuit. This isolation helps protect the DAQ hardware from voltage differences and transient events. Engineers should verify the isolation rating and the maximum switching voltage and current for the application.
Where signals are low level, contact resistance and thermal EMF can affect measurement accuracy. Where signals are higher power, contact life and arc suppression become important considerations.
SCXI Integration
The module operates in compatible SCXI chassis with appropriate DAQ hardware. SCXI systems provide signal conditioning and switching close to the sensors, then route signals to a DAQ device. System design should consider chassis configuration, module placement, and cable routing.
A documented channel map is important with relay modules. Engineers should record which test point or load connects to which channel, along with the voltage and current ratings used.
Software Control and Sequencing
The module is controlled through NI software and standard programming environments. Engineers can set relay states, create sequences, and synchronize switching with measurements. Software should include interlocks, fault handling, and safe state definitions so that a fault results in a known configuration.
Settling time should be allowed between closing a relay and starting a measurement. For load switching, inrush current and inductive kickback should be considered when sequencing.
Applications
The SCXI-1160 is suited to signal routing, load switching, test fixture control, and production verification. It supports software controlled relay switching in an SCXI system.
Installation and Maintenance
Installation requires mounting the module in an SCXI chassis and connecting load wiring according to the documentation. Wiring should be labeled and secured. The chassis should provide adequate cooling and protection.
Maintenance includes checking terminals, verifying relay operation, and reviewing software configuration. For critical systems, periodic testing of relay channels is recommended.
Summary
The National Instruments SCXI-1160 Relay Module provides isolated SPDT relay channels for SCXI systems. It supports signal routing, load control, and automated test. Careful planning of load compatibility, sequencing, and safe states makes the module a practical foundation for switching in SCXI test systems.