Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay
    ❤ Add to collection
  • PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥45757.00
      ¥48653.00
      ¥45757.00
      ¥45757.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.450KG
    • Quantity:
    • (Inventory: 6457)
Description
<span style="font-size: 18px; font-family: arial;">PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay</span>

Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 Safety Relay with Adjustable Dropout Delay

The Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 (Order No. 2981428) is a safety relay from the PSRclassic series designed for emergency stop and safety door monitoring applications. This device provides configurable safety functions with adjustable output timing, making it suitable for applications requiring controlled shutdown sequences. The relay supports functional safety up to SIL 3 according to IEC 61508/IEC 62061 or Category 4 Performance Level e according to EN ISO 13849-1 standards, enabling deployment in high-risk machinery safety applications.

Functional Capabilities and Input Modes

The safety relay supports both one-channel and two-channel operation modes, accommodating different safety circuit architectures. Two-channel operation with cross-circuit detection provides enhanced fault diagnostic coverage for safety gate monitoring applications. The device can be configured for automatic activation, where the safety outputs become active immediately upon closure of the input circuit, or for manual activation where a separate reset circuit must be closed to enable outputs after the input circuit is closed. This manual monitored start functionality prevents automatic machine restart after a power failure or after the safety circuit has been opened. The device is suitable for emergency stop circuits, safety door monitoring, and evaluation of light curtains in industrial equipment.


Output Configuration and Timing Functions

The PSR-SCP-24DC/ESD/5X1/1X2/300 features a mixed output configuration of timed and undelayed safety contacts. Three normally open (N/O) contacts provide undelayed switching, while two additional N/O contacts are configurable with a dropout delay ranging from 0.2 seconds to 300 seconds. The adjustable delay time can be set in 24 increments across this range, allowing precise matching to machine stop sequences or coast-down safety requirements. The delay applies only to the dropout (de-energization) of the timed outputs; the undelayed outputs drop out immediately upon safety circuit opening. One normally closed (N/C) auxiliary contact is provided for monitoring purposes, typically used to indicate relay state to a PLC or control system. Output contact configuration includes 5PST-NO and SPST-NC arrangement.

Delay Time Configuration and Security

The adjustable delay time is set using the ESD-300 time setting element, which allows precise configuration across the 0.2 s to 300 s range. Protective labels are available to prevent accidental manipulation of the set time once configured, ensuring that safety-critical timing parameters remain fixed during operation. For applications requiring permanent protection, electronic protection against manipulation is available with PSR-ESD-30 models. This security feature is essential for safety applications where unauthorized changes to delay settings could create hazardous conditions or violate safety standards compliance.

Electrical Specifications and Power Supply

The safety relay operates on a 24V DC supply voltage, with power consumption of approximately 3.72 W. The 24V DC input is the primary power source for internal logic, coil energization, and status indication. The contact switching voltage range spans from 5 to 250 V AC/DC, supporting both AC and DC loads on the output contacts. The device is designed for DIN rail mounting within a control cabinet environment. Plug-in screw terminal blocks are included for all field wiring connections, allowing module replacement without removing individual wires. Terminal size accepts standard industrial wiring gauges.

Safety Integrity and Compliance

The PSR-SCP-24DC/ESD/5X1/1X2/300 is certified for functional safety applications with EN ISO 13849-1 PL e (Category 4) and IEC 61508/IEC 62061 SIL 3 ratings. The device meets the requirements of EN 60947-5-1 for low-voltage switchgear and controlgear. Approvals include Functional Safety Approval ID 968/EZ408.05/23, UL Listed (FILE E 140324), cUL Listed (FILE E 140324), and EAC Approval ID TR_TS_D_00573_c. The product is also cULus Listed for use in North American installations. These certifications validate the device suitability for safety-related applications in machinery and process industries worldwide.


Environmental Ratings and Operation

Operating temperature range is appropriate for typical industrial control cabinet environments. The device is rated for use in industrial locations and complies with relevant EMC standards including immunity and emission requirements. The plastic housing is designed for DIN rail mounting and includes space for labeling and status indication LEDs. Standard PSRclassic series dimensions are 90 mm width for 24V DC models with time delay functionality.

Typical Applications

This safety relay is suitable for applications requiring timed safety outputs following a safety circuit opening, such as monitored stopping of rotating machinery where the machine must coast to a stop before the guard can be opened. The adjustable delay allows tuning to the specific machine deceleration time. Other applications include sequential machine shutdown where energized components must be powered down in a specific order, safe control of pneumatic or hydraulic valves where delayed de-energization is needed to prevent dangerous states, and integration with light curtains where the machine motion must stop within a defined time before operator access is permitted. The ability to mix timed and undelayed outputs provides flexibility in safety system design, allowing immediate removal of power from hazardous energy sources while maintaining timing for ancillary functions.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector