Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay
    ❤ Add to collection
  • PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥45757.00
      ¥48653.00
      ¥45757.00
      ¥45757.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.450KG
    • Quantity:
    • (Inventory: 6457)
Description
<span style="font-size: 18px; font-family: arial;">PSR-SCP-24DC-ESD-5x1-1x2-300 Safety Relay</span>

Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 Safety Relay with Adjustable Dropout Delay

The Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 (Order No. 2981428) is a safety relay from the PSRclassic series designed for emergency stop and safety door monitoring applications. This device provides configurable safety functions with adjustable output timing, making it suitable for applications requiring controlled shutdown sequences. The relay supports functional safety up to SIL 3 according to IEC 61508/IEC 62061 or Category 4 Performance Level e according to EN ISO 13849-1 standards, enabling deployment in high-risk machinery safety applications.

Functional Capabilities and Input Modes

The safety relay supports both one-channel and two-channel operation modes, accommodating different safety circuit architectures. Two-channel operation with cross-circuit detection provides enhanced fault diagnostic coverage for safety gate monitoring applications. The device can be configured for automatic activation, where the safety outputs become active immediately upon closure of the input circuit, or for manual activation where a separate reset circuit must be closed to enable outputs after the input circuit is closed. This manual monitored start functionality prevents automatic machine restart after a power failure or after the safety circuit has been opened. The device is suitable for emergency stop circuits, safety door monitoring, and evaluation of light curtains in industrial equipment.


Output Configuration and Timing Functions

The PSR-SCP-24DC/ESD/5X1/1X2/300 features a mixed output configuration of timed and undelayed safety contacts. Three normally open (N/O) contacts provide undelayed switching, while two additional N/O contacts are configurable with a dropout delay ranging from 0.2 seconds to 300 seconds. The adjustable delay time can be set in 24 increments across this range, allowing precise matching to machine stop sequences or coast-down safety requirements. The delay applies only to the dropout (de-energization) of the timed outputs; the undelayed outputs drop out immediately upon safety circuit opening. One normally closed (N/C) auxiliary contact is provided for monitoring purposes, typically used to indicate relay state to a PLC or control system. Output contact configuration includes 5PST-NO and SPST-NC arrangement.

Delay Time Configuration and Security

The adjustable delay time is set using the ESD-300 time setting element, which allows precise configuration across the 0.2 s to 300 s range. Protective labels are available to prevent accidental manipulation of the set time once configured, ensuring that safety-critical timing parameters remain fixed during operation. For applications requiring permanent protection, electronic protection against manipulation is available with PSR-ESD-30 models. This security feature is essential for safety applications where unauthorized changes to delay settings could create hazardous conditions or violate safety standards compliance.

Electrical Specifications and Power Supply

The safety relay operates on a 24V DC supply voltage, with power consumption of approximately 3.72 W. The 24V DC input is the primary power source for internal logic, coil energization, and status indication. The contact switching voltage range spans from 5 to 250 V AC/DC, supporting both AC and DC loads on the output contacts. The device is designed for DIN rail mounting within a control cabinet environment. Plug-in screw terminal blocks are included for all field wiring connections, allowing module replacement without removing individual wires. Terminal size accepts standard industrial wiring gauges.

Safety Integrity and Compliance

The PSR-SCP-24DC/ESD/5X1/1X2/300 is certified for functional safety applications with EN ISO 13849-1 PL e (Category 4) and IEC 61508/IEC 62061 SIL 3 ratings. The device meets the requirements of EN 60947-5-1 for low-voltage switchgear and controlgear. Approvals include Functional Safety Approval ID 968/EZ408.05/23, UL Listed (FILE E 140324), cUL Listed (FILE E 140324), and EAC Approval ID TR_TS_D_00573_c. The product is also cULus Listed for use in North American installations. These certifications validate the device suitability for safety-related applications in machinery and process industries worldwide.


Environmental Ratings and Operation

Operating temperature range is appropriate for typical industrial control cabinet environments. The device is rated for use in industrial locations and complies with relevant EMC standards including immunity and emission requirements. The plastic housing is designed for DIN rail mounting and includes space for labeling and status indication LEDs. Standard PSRclassic series dimensions are 90 mm width for 24V DC models with time delay functionality.

Typical Applications

This safety relay is suitable for applications requiring timed safety outputs following a safety circuit opening, such as monitored stopping of rotating machinery where the machine must coast to a stop before the guard can be opened. The adjustable delay allows tuning to the specific machine deceleration time. Other applications include sequential machine shutdown where energized components must be powered down in a specific order, safe control of pneumatic or hydraulic valves where delayed de-energization is needed to prevent dangerous states, and integration with light curtains where the machine motion must stop within a defined time before operator access is permitted. The ability to mix timed and undelayed outputs provides flexibility in safety system design, allowing immediate removal of power from hazardous energy sources while maintaining timing for ancillary functions.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor