Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Pilz 828010 S1IM Safety Relay
    ❤ Add to collection
  • Pilz 828010 S1IM Safety Relay

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥35637.00
      ¥37544.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.450KG
    • Quantity:
    • (Inventory: 6457)
Description
<span style="font-size: 18px; font-family: arial;">Pilz 828010 S1IM Safety Relay</span>

Pilz 828010 S1IM Current Monitoring Safety Relay

The Pilz 828010 S1IM is a precision current monitoring safety relay designed to monitor maximum current values in industrial electrical circuits. Part of Pilz's monitoring relay portfolio, the S1IM provides reliable overcurrent detection for motors, pumps, heating elements, and other electrical loads, helping to prevent equipment damage and ensure operational safety. The device combines compact design with flexible configuration options, making it suitable for panel mounting in control cabinets across manufacturing, process, and infrastructure applications.

Measuring Ranges and Configuration

The S1IM offers 12 selectable measuring ranges covering 0.01 A to 15 A, allowing the same device to be used across a wide variety of load currents. Range selection is performed via rotary switches on the front panel, eliminating the need for external current transformers for most applications. The relay monitors the true RMS value of the input current and can be set to trip when the current exceeds a user-defined threshold. An adjustable time delay prevents nuisance tripping during motor starting or other temporary inrush events. The device supports monitoring of frequencies from 0 to 400 Hz, making it compatible with both AC and DC current signals.


Technical Specifications

The Pilz 828010 operates from a 24 V DC supply voltage with a power consumption of just 1 W. The supply voltage type is DC, with a nominal voltage of 24 V. Dimensions are 87 mm in height, 22.5 mm in width, and 121 mm in depth, conforming to the slim profile standard for DIN rail mounting. The net weight is 125 g, and the housing material consists of PPO (UL 94 V0) for the lower and upper sections, with an ABS UL 94 V0 front plate. Terminal protection type is IP20, while the housing itself is rated IP40. Mechanical data indicates the mounting position is flexible, suitable for any orientation. Connection terminals are fixed screw terminals, accepting 24 to 10 AWG flexible conductors.

Output and Contact Data

The relay output contacts are constructed from AgCdO material with a 3.0 μm gold plating, ensuring reliable low-current switching even in dry circuit applications. Utilisation category according to EN 60947-4-1 is AC/DC1 stand., and AC15/DC13 according to EN 60947-5-1. Safety contacts at 240 V AC are rated for resistance switching. The pilot duty rating is B300 and R300. Maximum conductor cross-section for the relay outputs is sized appropriately for the current rating, with a maximum device circuit breaker specification limiting the protection device rating.

Approvals and Environmental Compliance

The Pilz 828010 carries multiple international approvals, including CE for the European market, UKCA for Great Britain, cULus Listed for North America, and CCC for China. Environmental compliance includes the RoHS directive (2011/65/EU and 2015/863/EU), with RoHS conformity verified. Due to the presence of lead as a SVHC substance, REACh compliance is declared with lead content exceeding 0.1% by weight (CAS No. 7439-92-1). A SCIP entry is available for the product. The WEEE classification group is 5 for devices with a feed size below 50 cm. Climatic suitability meets EN 60068-2-78 standards, with condensation not permitted. EMC conformity follows EN 60947-5-1 and EN 61000-6-2. Vibration testing meets EN 60068-2-6. Clearance and creepage distances conform to EN 60947-1 requirements.

Environmental Ratings and Installation

Operating ambient temperature range is from -15°C to 55°C, supporting installation in unheated industrial enclosures. The device should be mounted on a standard 35 mm DIN rail inside a control cabinet with at least IP54 protection. Adequate ventilation should be provided to maintain the ambient temperature within the specified range. The S1IM is not suitable for outdoor installation or environments with condensation, as moisture ingress would degrade the internal electronics over time.

Applications

Typical applications for the Pilz S1IM include monitoring of motor currents to detect overloads or phase loss, pump protection against dry running or blockage, heating element monitoring to detect open circuits, and general overcurrent protection for industrial loads. The relay can be integrated into safety circuits where overcurrent detection is required to initiate a safe shutdown. When combined with a suitable contactor, the S1IM can interrupt power to a load automatically when current exceeds the configured threshold, preventing thermal damage and fire hazards. The compact 22.5 mm width allows multiple units to be mounted side-by-side in high-density control panels, conserving valuable cabinet space.

Maintenance and Servicing

No routine calibration is required for the S1IM, as the measuring circuit is factory-calibrated and stable over time. The front-panel LEDs provide visual indication of power, trip status, and relay state for quick diagnostics. In the event of a fault, the relay output de-energizes and must be reset either manually (via the front button) or automatically (depending on configuration). Periodic inspection of terminal tightness and visual check for signs of overheating or contamination is recommended during scheduled plant shutdowns. The device contains no user-serviceable parts; internal repairs require factory service or authorized replacement.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide