Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Pilz 828010 S1IM Safety Relay
    ❤ Add to collection
  • Pilz 828010 S1IM Safety Relay

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥35637.00
      ¥37544.00
      ¥35637.00
      ¥35637.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.450KG
    • Quantity:
    • (Inventory: 6457)
Description
<span style="font-size: 18px; font-family: arial;">Pilz 828010 S1IM Safety Relay</span>

Pilz 828010 S1IM Current Monitoring Safety Relay

The Pilz 828010 S1IM is a precision current monitoring safety relay designed to monitor maximum current values in industrial electrical circuits. Part of Pilz's monitoring relay portfolio, the S1IM provides reliable overcurrent detection for motors, pumps, heating elements, and other electrical loads, helping to prevent equipment damage and ensure operational safety. The device combines compact design with flexible configuration options, making it suitable for panel mounting in control cabinets across manufacturing, process, and infrastructure applications.

Measuring Ranges and Configuration

The S1IM offers 12 selectable measuring ranges covering 0.01 A to 15 A, allowing the same device to be used across a wide variety of load currents. Range selection is performed via rotary switches on the front panel, eliminating the need for external current transformers for most applications. The relay monitors the true RMS value of the input current and can be set to trip when the current exceeds a user-defined threshold. An adjustable time delay prevents nuisance tripping during motor starting or other temporary inrush events. The device supports monitoring of frequencies from 0 to 400 Hz, making it compatible with both AC and DC current signals.


Technical Specifications

The Pilz 828010 operates from a 24 V DC supply voltage with a power consumption of just 1 W. The supply voltage type is DC, with a nominal voltage of 24 V. Dimensions are 87 mm in height, 22.5 mm in width, and 121 mm in depth, conforming to the slim profile standard for DIN rail mounting. The net weight is 125 g, and the housing material consists of PPO (UL 94 V0) for the lower and upper sections, with an ABS UL 94 V0 front plate. Terminal protection type is IP20, while the housing itself is rated IP40. Mechanical data indicates the mounting position is flexible, suitable for any orientation. Connection terminals are fixed screw terminals, accepting 24 to 10 AWG flexible conductors.

Output and Contact Data

The relay output contacts are constructed from AgCdO material with a 3.0 μm gold plating, ensuring reliable low-current switching even in dry circuit applications. Utilisation category according to EN 60947-4-1 is AC/DC1 stand., and AC15/DC13 according to EN 60947-5-1. Safety contacts at 240 V AC are rated for resistance switching. The pilot duty rating is B300 and R300. Maximum conductor cross-section for the relay outputs is sized appropriately for the current rating, with a maximum device circuit breaker specification limiting the protection device rating.

Approvals and Environmental Compliance

The Pilz 828010 carries multiple international approvals, including CE for the European market, UKCA for Great Britain, cULus Listed for North America, and CCC for China. Environmental compliance includes the RoHS directive (2011/65/EU and 2015/863/EU), with RoHS conformity verified. Due to the presence of lead as a SVHC substance, REACh compliance is declared with lead content exceeding 0.1% by weight (CAS No. 7439-92-1). A SCIP entry is available for the product. The WEEE classification group is 5 for devices with a feed size below 50 cm. Climatic suitability meets EN 60068-2-78 standards, with condensation not permitted. EMC conformity follows EN 60947-5-1 and EN 61000-6-2. Vibration testing meets EN 60068-2-6. Clearance and creepage distances conform to EN 60947-1 requirements.

Environmental Ratings and Installation

Operating ambient temperature range is from -15°C to 55°C, supporting installation in unheated industrial enclosures. The device should be mounted on a standard 35 mm DIN rail inside a control cabinet with at least IP54 protection. Adequate ventilation should be provided to maintain the ambient temperature within the specified range. The S1IM is not suitable for outdoor installation or environments with condensation, as moisture ingress would degrade the internal electronics over time.

Applications

Typical applications for the Pilz S1IM include monitoring of motor currents to detect overloads or phase loss, pump protection against dry running or blockage, heating element monitoring to detect open circuits, and general overcurrent protection for industrial loads. The relay can be integrated into safety circuits where overcurrent detection is required to initiate a safe shutdown. When combined with a suitable contactor, the S1IM can interrupt power to a load automatically when current exceeds the configured threshold, preventing thermal damage and fire hazards. The compact 22.5 mm width allows multiple units to be mounted side-by-side in high-density control panels, conserving valuable cabinet space.

Maintenance and Servicing

No routine calibration is required for the S1IM, as the measuring circuit is factory-calibrated and stable over time. The front-panel LEDs provide visual indication of power, trip status, and relay state for quick diagnostics. In the event of a fault, the relay output de-energizes and must be reset either manually (via the front button) or automatically (depending on configuration). Periodic inspection of terminal tightness and visual check for signs of overheating or contamination is recommended during scheduled plant shutdowns. The device contains no user-serviceable parts; internal repairs require factory service or authorized replacement.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials