The CSH01.1C-ET-ENS-NNN-NNN-S2-S-NN-FW, part number R911328178, and the HMS01.1N-W0020-A-07-NNNN together form a single-axis drive package within the Rexroth IndraDrive modular system. The control section contributes the motion control electronics, EtherCAT communication, encoder evaluation, and safety functions. The power section provides the three-phase inverter stage and the thermal management components required for continuous operation. The two modules are matched to operate as one drive unit in an industrial cabinet, with the control section mounted onto the power section and connected through the drive’s internal interface.
The ET segment of the CSH01.1C type code identifies EtherCAT as the field communication interface. EtherCAT is a real-time Ethernet protocol that supports deterministic cyclic exchange of process data between the drive and a higher-level controller. The control section participates in an EtherCAT network as a slave device, receiving position and velocity commands and returning actual position, status, and diagnostic information. The control section also provides a multi-Ethernet interface that enables master communication with remote input and output devices and linked modules, extending the drive’s role beyond a single axis to include coordination with distributed peripheral equipment.
The control section supports both digital and analog input and output devices and various encoder types, giving the drive package flexibility across different machine architectures. The control panel on the section provides local access to drive functions and diagnostic data without requiring a programming tool. The NNN segments indicate that optional expansion slots are unpopulated in this configuration, keeping the control section focused on its base communication, encoder, and safety functions.
The ENS segment specifies the encoder evaluation variant. The control section is designed for IndraDyn and Hiperface motor feedback, providing the position and velocity signals required for commutation and closed-loop control. The Hiperface interface is a digital serial protocol that transmits absolute position data, and the control section’s encoder front end processes these signals for use by the drive’s current, velocity, and position loops. The S2 segment adds Safe Motion functionality, which extends the drive’s safety capabilities to include monitored stop and limited-speed functions integrated into the control section rather than relying on external safety relays for every stop category. The FW suffix confirms that the control section is factory-loaded with firmware, ensuring a defined software baseline for the EtherCAT interface, encoder evaluation, and safety functions.
The HMS01.1N-W0020-A-07-NNNN is an air-cooled IP20 IndraDrive M power section for one axis, using a 254 to 750 VDC bus input and delivering a three-phase motor output. The W0020 designation identifies the 20 A maximum current class. Within that class, the continuous output current is 12.1 A at a 4 kHz switching frequency and 8.3 A at 8 kHz. The rated input current is 14.0 A, and the output voltage range is 0 to 500 VAC three-phase. The control voltage requirement is 24 VDC with a tolerance of plus or minus 20 percent, and the rated control-voltage power is 10 W excluding the motor holding brake, control section, and safety option.
The power section uses forced-air cooling with a capacity of 27 cubic meters per hour, and the permissible ambient temperature is 0 to 40 degrees Celsius at nominal data, with operation at reduced nominal data up to 55 degrees Celsius and a derating of 2 percent per Kelvin above the nominal range. The minimum clearance requirement is 80 mm at the top and 100 mm at the bottom, reflecting the airflow path required for reliable thermal operation. The module dimensions are 5.0 by 44.0 by 26.2 centimeters, and the weight is 5.27 kilograms.
When the control section and power section are assembled, the control section executes the position, velocity, and current control loops, processes the Hiperface encoder feedback, exchanges process data over EtherCAT, and enforces the Safe Motion functions. The power section converts the DC bus voltage into the motor voltage and current, monitors the output stage, and provides thermal diagnostic data to the control section. The modular separation allows the power section to be selected according to the motor current requirement, while the control section is selected according to the communication interface, encoder type, and safety profile. In a multi-axis system, multiple drive packages can share a common DC bus and operate on the same EtherCAT network, simplifying cabling and coordination across the machine.