  • ST2000 34 Algorab Graphic PLC Terminal
    ❤ Add to collection
  • ST2000 34 Algorab Graphic PLC Terminal

    • ¥64522.00
      ¥66347.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.340KG
    • Quantity:
    • (Inventory: 4636)
Description
<span style="font-size: 20px; font-family: arial;">ST2000 34 Algorab Graphic PLC Terminal</span>

ST2000 34 Algorab 008 95/49 Graphic PLC Terminal for Industrial Control

The ST2000 34 Algorab 008 95/49 is an advanced graphic programmable logic controller terminal designed for industrial automation and remote control applications. Developed by Algorab, an Italian company specializing in cutting-edge remote control and IoT systems, this terminal integrates intelligent data acquisition capabilities with a sophisticated operator interface. The ST2000 34 functions as both a traditional analog instrument replacement and a modern digital controller, offering enhanced functionality for demanding industrial environments.

Product Overview

The ST2000 34 is designed as a direct replacement for traditional analog transmitters and display instruments in industrial automation systems. Unlike conventional analog instruments, the ST2000 34 incorporates a microprocessor that provides temperature compensation to eliminate temperature effects and improve measurement accuracy. This intelligent design ensures consistent performance across varying environmental conditions, making it suitable for applications requiring precise control and reliable operation. The terminal combines data acquisition, control, display, and communication functions in a single integrated unit, simplifying system architecture and reducing component count.


Graphic Display and User Interface

The ST2000 34 features an advanced graphic display that presents process data, machine status, and operator controls in an organized, easy-to-read format. The high-resolution screen supports clear visualization of numerical values, trend graphs, alarm messages, and interactive control elements. Operators can navigate through multiple screen pages using the intuitive interface, accessing different functions including parameter configuration, production monitoring, and diagnostic information. The graphic display enhances operator efficiency by presenting relevant information in a structured manner, reducing the time required to interpret data and make informed decisions.

Data Acquisition and Processing Capabilities

The terminal is equipped with comprehensive data acquisition capabilities for monitoring industrial processes and equipment. It can acquire both analog and digital input signals from field sensors, transmitters, and switches, processing this information for display, logging, and control purposes. The built-in microprocessor executes programmed logic, performing calculations, comparisons, and decision-making based on acquired data. This local processing capability reduces the load on central control systems and enables rapid response to changing process conditions. The terminal can automatically execute programmed control sequences, handling analog and digital input/output operations without requiring constant supervision from a host controller.


Communication and Connectivity

The ST2000 34 supports industrial communication protocols for integration with host systems and supervisory control networks. It communicates with upper-level computers using the 203_Optomux protocol, a well-established standard for industrial automation data exchange. This communication capability allows the terminal to transmit acquired data to SCADA systems, data historians, and manufacturing execution systems for centralized monitoring and analysis. The terminal can also receive setpoints and commands from host systems, enabling remote configuration and control of local processes. The communication interface supports reliable data transfer in electrically noisy industrial environments.

Temperature Compensation and Accuracy

A key feature of the ST2000 34 is its microprocessor-based temperature compensation system. Traditional analog instruments are susceptible to measurement errors caused by temperature variations in the operating environment. The ST2000 34 continuously monitors ambient temperature and applies correction factors to eliminate these errors, ensuring consistent measurement accuracy across the specified operating temperature range. This temperature compensation is particularly valuable for applications where the instrument may be exposed to fluctuating environmental conditions, such as outdoor installations, unheated facilities, or machinery enclosures with variable thermal loads.

Industrial Applications

The ST2000 34 Algorab graphic PLC terminal is suitable for a wide range of industrial automation and remote control applications. In manufacturing facilities, it provides operator interface and local control for individual machines or production cells. In process industries, it monitors and controls temperature, pressure, flow, and other process variables at local stations. In infrastructure applications, it serves as a remote terminal unit for monitoring pumps, valves, and other equipment at distributed sites. The terminal's combination of data acquisition, display, and communication capabilities makes it adaptable to various industrial scenarios requiring localized intelligence with centralized supervision.

Intelligent Remote Control Integration

Algorab specializes in adaptive and efficient remote control systems for industrial and infrastructure applications. The ST2000 34 reflects this expertise, offering intelligent remote control capabilities that reduce communication bandwidth requirements and improve system responsiveness. By processing data locally and transmitting only relevant information to central systems, the terminal optimizes network utilization and reduces the latency associated with centralized processing architectures. This distributed intelligence approach is particularly effective for applications with large numbers of remote points or limited communication bandwidth.


Robust Construction for Industrial Environments

The ST2000 34 is constructed with industrial-grade components selected for reliability in demanding operating conditions. The enclosure provides protection against dust, moisture, and mechanical impact appropriate for industrial installation. The terminal is designed to withstand temperature variations, humidity, and vibration common in manufacturing and process facilities. The robust construction ensures long service life and consistent performance, reducing maintenance requirements and minimizing downtime due to instrument failure.

Communication Protocol Support

The terminal supports the 203_Optomux communication protocol, enabling integration with a wide range of industrial automation systems. This protocol provides reliable data exchange between the terminal and host computers, supporting both read and write operations for process variables and configuration parameters. The protocol implementation includes error checking and recovery mechanisms that ensure data integrity even in electrically noisy environments. The communication interface supports standard wiring practices, facilitating installation by industrial electricians and system integrators.


Analog and Digital I/O Capabilities

The ST2000 34 provides both analog and digital input/output capabilities for connection to field devices. Analog inputs accept standard industrial signals including 4-20 mA current loops and voltage signals from transmitters. Analog outputs provide control signals for valves, actuators, and variable frequency drives. Digital inputs accept signals from switches, pushbuttons, and proximity sensors. Digital outputs drive relays, solenoids, and indicator lights. This comprehensive I/O capability allows the terminal to interface directly with field devices without requiring additional signal conditioning equipment.

Configuration and Programming

The ST2000 34 can be configured and programmed using engineering software that supports function block, ladder logic, or structured text programming languages according to application requirements. The configuration environment provides tools for defining I/O assignments, control algorithms, alarm conditions, and communication parameters. Program logic can be developed offline and downloaded to the terminal via its communication interface. The configuration can be modified as process requirements change, providing flexibility for evolving applications.

Conclusion

The ST2000 34 Algorab 008 95/49 graphic PLC terminal provides intelligent data acquisition, operator interface, and remote control capabilities for industrial automation applications. With temperature compensation, graphic display, and flexible communication, it serves as a versatile solution for localized control with centralized supervision.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting
  • ADLINK PCIe-GIE72/74 Image Acquisition Card Deployment Guide
  • ADLINK PCIe-7856/7853 Sports I/O Controller Card Guide
  • ADLINK PCI-6308 Isolation Output Card Programming and Installation
  • ADLINK PCI-7432 installation and configuration troubleshooting
  • adlink nupro-e72 التحكم الصناعي اللوحة
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules