Westinghouse 2400i digital inverter generator

来源: | 作者:FAN | 发布时间 :2025-11-13 | 9 次浏览: | Share:

Westinghouse 2400i digital inverter generator

Detailed explanation of core product information

1. In depth analysis of technical parameters

Category parameter details note explanation

The engine system has a single cylinder four stroke overhead valve (OHV), and the air-cooled OHV design improves combustion efficiency and extends engine life; Air cooled structure simplifies maintenance and adapts to complex outdoor environments

Power parameters: displacement of 79cm ³, maximum speed of 5000rpm, intelligent adjustment of speed with load (operating at the lowest speed in ECO mode)

Oil specification: The oil capacity is 400mL. It is recommended to use SAE 15W-40 API SG grade for ambient temperatures greater than 40 ℃, and 10W-30 for temperatures ≤ 40 ℃; It is strictly prohibited to mix different types of engine oil

Unleaded gasoline (91 octane and above) for the fuel system, with an ethanol content of ≤ 10%. If the ethanol content in the 5.0L fuel tank is too high, it is easy to cause corrosion of the fuel system. It is recommended to prioritize the use of ethanol free gasoline; Under full fuel condition, ECO mode can run for 8-10 hours

AC output 240V/50Hz, continuous power 2100W, starting power 2400W pure sine wave output, total harmonic distortion<3%, suitable for sensitive equipment such as computers and precision instruments

DC output 12V, maximum current 8A, maximum power 100W. The output is non regulated to avoid connecting devices that are sensitive to voltage fluctuations (such as precision electronic devices)

The protection level of the socket is IP44, which can resist splashing water but cannot be exposed to rain or soaking

Physical characteristics: length 500mm x width 340mm x height 440mm, dry weight 20kg. The handle design is convenient for single person short distance transportation, and the wet weight includes the weight of engine oil and fuel

2. Complete analysis of control panel functions

Component Name Function Description Operation Points

240V AC 15A socket (2 sockets) outputs 240V AC power, with a maximum load of 2400W per socket. When inserting the plug, it needs to be fully pushed in and the waterproof cover should be closed after use

Press and hold the engine stop button to stop the engine. In emergency situations, it can be used directly. Normal shutdown requires disconnecting the load first and running without load for 1 minute before operation

After the reset button of the generator is overloaded or short circuited, after troubleshooting, it is necessary to ensure that the load does not exceed the standard before resetting the AC output, otherwise the protection will be triggered again

ECO throttle switch ON: energy-saving mode, OFF: standard mode. ECO mode is used for small loads (<1000W), and standard mode is used for large loads (>1500W) or inductive loads

Throttle knob START (cold start), RUN (hot run) After starting the cold engine, preheat the engine for 3-5 minutes before pushing it to the RUN position to avoid stuffiness

Multi functional VST instrument displays voltage, speed, and cumulative running time. Press the panel button to switch display modes, and the backlight can be illuminated in low light environments

Fuel control switch ON (run), OFF (stop) should be turned to OFF for long-term storage, and the machine should be stopped after running out of fuel

The low oil warning light (red) lights up when the oil level is too low, and the engine automatically shuts down. It needs to be refilled with oil to the standard level before restarting

Overload alarm light (red) lights up when the load exceeds the standard or short circuit occurs. To cut off the AC output, the load needs to be reduced or the short circuit fault needs to be eliminated before resetting

Output indicator light (green) lights up when the engine is running and the AC output is normal. The green light does not light up but the engine is running. It is necessary to troubleshoot the output fault

Connect the grounding terminal to the ground wire to enhance electrical safety. It is recommended to ground when outdoors in humid environments or when connecting metal enclosed equipment

12V DC socket outputs 12V DC power, compatible with cigarette lighter plug. Do not insert into car cigarette lighter (high temperature can easily cause fire)

3. Function and position of core components

Air filter: located on the right side of the body, filters dust from the intake air to prevent engine cylinder wear; Regular cleaning is required, and the cycle should be shortened in dusty environments.

Spark plug: located on the left side of the body, it generates an electric spark to ignite the fuel mixture; Carbon deposition or wear can cause difficulty in starting and unstable operation.

Spark arrester: installed at the outlet of the muffler to prevent sparks from escaping and causing fires; When used in outdoor or dry environments, it is necessary to ensure cleanliness and smoothness.

Fuel filter: located below the fuel inlet inside the fuel tank, filters impurities in the fuel to avoid clogging the fuel injectors.

Oil inspection cover: on the left side of the body, open to check or add oil; The oil filling port is threaded, so avoid over tightening and damaging the threads when tightening.

Fuel emission hose: located at the bottom of the left side of the aircraft, used to drain the fuel from the tank (such as during long-term storage or when the fuel deteriorates).

image.png

Safety operation rules (including risk avoidance)

1. Environmental safety requirements

The operating position should meet the following requirements: good outdoor ventilation, away from doors, windows, ventilation openings, tents, etc. (to prevent the accumulation of carbon monoxide); The ground is flat and hard (to avoid vibration and tilting during operation, which may cause fuel/oil leakage); Maintain a distance of at least 1.8m from combustible materials such as wood, hay, paint, etc., and maintain a heat dissipation space of at least 0.5m from other equipment.

Prohibited from use in the following scenarios: confined spaces (indoor, garage, basement), damp ground (waterlogged, muddy), thunderstorm weather, and high dust concentration environments (such as construction site dust areas).

Extreme environmental response: When operating at high temperatures (>35 ℃), it is necessary to operate in a cool place and avoid direct sunlight; When the temperature is low (<0 ℃), winter specific engine oil (such as 5W-30) should be used, and the engine block can be preheated before starting (to avoid open flame heating).

2. Fuel safety operation

Preparation before refueling: Turn off the engine and wait for at least 10 minutes for it to cool down (the muffler temperature can reach over 400 ℃, which can easily ignite the fuel); Clean the oil around the fuel filler to prevent impurities from entering the fuel tank.

Refueling operation: Use a dedicated refueling pot to slowly refuel, with the oil level not exceeding the red limit ring in the fuel tank (reserve 5-10% expansion space); If fuel spills, immediately wipe it clean with a dry cloth and wait for it to evaporate before starting the engine.

Fuel storage: Backup fuel should be stored in a qualified fuel container, in a ventilated, cool, and away from sources of fire, for a period of no more than 3 months (with the addition of fuel stabilizers, it can be extended to 6 months).

Forbidden operation: Do not refuel while the engine is running; Prohibit using fuel to clean equipment; Do not place fuel containers on the generator or near heat sources.

3. Electricity safety regulations

Extension cable selection: 240V AC extension cables must comply with AS/NZS 3199:2007 standards, using 15A heavy-duty three core cables (core cross-sectional area ≥ 1.5mm ²), with a length not exceeding 25m (1.5mm ²) or 40m (2.5mm ²); The length of the 12V DC extension cable shall not exceed 3.5m, and the cross-sectional area of the wire core shall be ≥ 1.0mm ².

Load calculation method:

Pure resistance load (light bulb, heater, rice cooker): starting power=operating power, total operating power ≤ 2100W.

Inductive loads (air conditioning, water pump, motor): starting power=operating power x 1.2 (small portable equipment) or 3.5 (large fixed equipment), total starting power ≤ 2400W.

Example: 1.5kW air conditioner (operating power 1500W), starting power=1500 × 3.5=5250W>2400W, cannot be driven separately; 0.8kW water pump (operating power 800W), starting power=800 × 1.2=960W, can be driven.

Grounding requirements: The generator itself has an equipotential connection system and does not require separate grounding; If connecting fixed equipment or using in humid environments, a certified electrician must connect the grounding terminal to the grounding electrode (such as a metal grounding rod).

Emergency response: In case of equipment tripping, heating, or odor during power consumption, immediately disconnect the load, shut down the generator, and troubleshoot before use.

4. Personnel safety protection

Wear goggles (to prevent fuel splashes and debris from entering the eyes) and gloves (to prevent oil contamination and burns) during operation; Long hair should be curled up to avoid getting caught up in moving parts.

Children and pets are prohibited from entering within a 1m radius of the generator; Operators need to be familiar with the operating procedures and avoid operating under the influence of alcohol or fatigue.

Emergency situation handling: In case of fuel leakage, immediately stop operation, stay away from the scene, and clean up after the fuel evaporates; If a fire occurs, use ABE or BE type fire extinguishers to extinguish it (it is prohibited to directly extinguish electrical fires with water); If you feel dizzy or nauseous after inhaling carbon monoxide, immediately transfer to a well ventilated area and seek medical attention in severe cases.


Step by step operation guide (including key details)

1. Preparation for the first use of the new machine

Open the box inspection: Open the packaging and take out the generator and accessories (400mL SAE 15W-40 engine oil, fuel can, screwdriver, spark plug socket wrench, dust cover, instruction manual); Check that the appearance of the generator is undamaged, the components are not loose, and the sockets and switches are functioning properly.

Oil filling:

Place the generator on a level surface and open the left oil maintenance cover.

Clean the area around the oil filling port with a clean cloth to prevent impurities from entering.

Using the included fuel can, slowly add oil to the bottom edge of the filling port (the oil level should be level with the filling port and not overflow).

Tighten the oil filling plug, close the maintenance cover, and wipe off any remaining oil.

Fuel filling:

Unscrew the fuel cap (counterclockwise) and clean the area around the fuel port.

Add unleaded gasoline of grade 91 or above, with the fuel level not exceeding the red limit ring inside the fuel tank.

Tighten the fuel cap (clockwise), turn the fuel cap vent to the ON position, and check for fuel leaks.

2. Start up process (including differences in cooling/heating)

Step operation content: Key points for starting a cold machine, key points for starting a hot machine

1. Environmental and status confirmation: Outdoor ventilation, flat and dry ground, disconnect all loads and start the refrigeration unit

2. Prepare the fuel system and turn the fuel control switch to ON. Turn the fuel cap vent to ON and start the cooling machine

Adjust the air damper to the START position (fully pulled out) and keep it in the RUN position (pushed in)

4. Start operation: Hold down the generator body with one hand (to prevent vibration displacement), and hold the recoil start handle with the other hand. Slowly pull until you feel an increase in resistance (piston compression stroke), then quickly and forcefully pull the handle. After starting, slowly release it back (to avoid the handle rebounding and hitting the body). The pulling resistance is small and does not require excessive force. Keep running directly after starting

After preheating and adjusting the engine, let it idle for 3-5 minutes, gradually push the throttle to the RUN position, and observe that the instrument voltage stabilizes at around 240V without prolonged preheating. After starting, connect a light load

3. Operation and monitoring during operation

Load connection:

Confirm that the generator is running stably and the output indicator light (green) is on.

240V equipment: directly plugged into an AC socket or connected through a qualified extension cord; Ensure that the plug is fully in contact during insertion to avoid loosening and overheating.

12V device: Insert the cigarette lighter plug into the DC socket, ensuring that the plug is securely fastened; The total power shall not exceed 100W.

Operation monitoring:

Real time monitoring of instruments: The voltage should be stable between 230-250V, and the speed should vary with the load (in ECO mode, the lower the load, the lower the speed).

Monitor engine sound: During normal operation, the sound is uniform and there is no abnormal noise (such as knocking or whistling); If there is any abnormal noise, stop the machine immediately for inspection.

Check the indicator lights: both the low fuel alarm light and the overload alarm light should be turned off; If it lights up, follow the troubleshooting process.

load regulation:

To avoid sudden connection of high-power loads (such as air conditioning and water pumps), the load switch should be turned off first, and then gradually turned on after connection.

When multiple devices are used simultaneously, connect the low-power device first and then the high-power device to ensure that the total starting power does not exceed 2400W.

If there is an overload alarm (red light on), immediately disconnect part of the load, wait for 30 seconds, press the reset button, and then reconnect.

4. Shutdown process (including different scenarios)

Precautions for operating steps in shutdown scenarios

Normal shutdown: 1. Disconnect all loads (unplug or turn off the device switch); 2. Run the generator without load for 1 minute (cool down the engine and generator); 3. Press and hold the engine stop button until the engine is completely stopped; 4. Turn the fuel control switch to OFF; 5. Turn the fuel cap vent to OFF; 6. Close all waterproof covers of sockets and cover them with dust covers (if not used for a long time). Do not stop the machine directly, otherwise it may cause carbon buildup in the engine and overheating of the generator

Emergency shutdown (such as fire or leakage): Press and hold the engine stop button until the machine stops; Follow the normal process to check for faults and use them again after troubleshooting. Only for emergency situations, frequent emergency shutdowns may affect the lifespan of the equipment

Long term shutdown (over 1 week): 1. Disconnect all loads and run without load for 1 minute; 2. Turn the fuel control switch to OFF and allow the engine to continue running until the fuel runs out and automatically shuts down; 3. Close the fuel cap vent; 4. Drain the engine oil (if not used for more than 3 months); 5. Clean the surface of the generator and cover it with a dust cover to prevent fuel from deteriorating and blocking the oil circuit, thus extending the storage life

5. Two methods for charging 12V batteries (including safety points)

Method 1: Direct charging from DC socket (emergency use)

Tool preparation: 12V DC charging cable (with cigarette lighter plug and crocodile clip, rated current ≥ 8A), battery to be charged (12V lead-acid battery).

Operation steps:

Start the generator according to the normal procedure and turn off the ECO mode after stable operation.

Clean the positive and negative terminals of the battery and remove oxides (gently rub with sandpaper).

Connect the crocodile clip of the charging cable to the battery: the red clip is connected to the positive pole (+), and the black clip is connected to the negative pole (-), ensuring clamping (to avoid poor contact and heat generation).

Insert the cigarette lighter plug of the charging cable into the 12V DC socket of the generator.

During the charging process, maintain a distance of at least 1m between the battery and the generator (to prevent hydrogen explosions during battery charging), monitor the battery temperature in real-time, and immediately stop charging if the battery is hot or the electrolyte boils.

Charging time: adjusted according to battery capacity, generally not exceeding 3 hours; When there is no monitoring tool, disconnect after charging for 2 hours and test the battery voltage (full charge voltage is about 12.6V).

Charging completed: First unplug the cigarette lighter plug, then disconnect the crocodile clip (negative first, positive later), and cover the battery vent caps.

Method 2: Charging the AC socket through a charger (recommended)

Tool preparation: A 12V battery charger with 240V AC input (compatible with battery types such as lead-acid and lithium batteries).

Operation steps:

Start the generator and connect the charger power plug to a 240V AC socket after stable operation.

Connect the battery according to the charger manual (positive to positive, negative to negative).

Turn on the charger and set the appropriate charging mode (such as constant voltage, constant current).

During the charging process, monitor the charger indicator light and battery temperature, and complete the charging according to the charger prompts.

Charging completed: Turn off the charger, unplug the power plug, disconnect the battery connection, and stop the generator.

Advantages: The charger can intelligently adjust the charging current and voltage, avoiding overcharging and damaging the battery, and has higher safety.

image.png

Complete maintenance process (including cycle and operation details)

1. Preparation before maintenance

Safety measures: Turn off the generator and remove the spark plug cap (to prevent accidental starting); Let the engine cool to room temperature (to avoid scalding of high-temperature components); Operate in a well ventilated area and prepare tools such as cloths, wrenches, containers, etc.

Tool list: Phillips screwdriver, Phillips screwdriver, spark plug socket wrench, oil pan, funnel, wire brush, compressed air (optional), new engine oil, new spark plug (spare).

2. Routine maintenance items (executed on a periodic basis)

Before/after each use

Cleaning: Use a damper cloth to wipe the dust and oil stains on the surface of the generator, and clean the debris from the heat dissipation port and ventilation hole (to avoid blockage that affects heat dissipation).

Check:

Appearance: The components are not loose or damaged, and the socket has no burn marks.

Oil: The oil level is within the standard range and there is no leakage; There is no fuel leakage and the fuel gauge shows sufficient.

Wiring: The wires are not damaged or aged, and the plugs are securely connected.

Every 20 hours (after first use)

Oil change:

Place the generator on a level surface, start the engine and run it for 1 minute (allowing the oil to flow and facilitate drainage), then stop it.

Open the oil inspection cover, clean the area around the filling port, and place the oil basin under the filling port.

Unscrew the oil filler plug, tilt the generator, and allow the old oil to flow completely into the oil pan (about 5 minutes).

Tighten the oil filling plug and add 400mL of new oil (SAE 15W-40 API SG grade) through the funnel.

Tighten the filling plug, start the engine and run it for 1 minute, check if the oil level is normal and if there are any leaks.

Old engine oil treatment: Pour into a sealed container and hand it over to a professional organization for recycling (no dumping at will).

Every 50 hours/3 months

Air filter cleaning:

Unscrew the 6 screws of the air filter maintenance cover on the right side of the body, and remove the maintenance cover and air filter cover (with the central screw).

Take out the foam filter element and pay attention to the position of the bevelled corner (easy to replace).

Clean the filter element with warm water and a small amount of detergent, gently squeeze (without twisting or tearing), and remove dust and oil stains.

Rinse with clean water, squeeze and drain the water, then use a dry cloth to absorb any remaining moisture (or air dry naturally, do not expose to direct sunlight).

Apply a thin layer of engine oil evenly on the surface of the filter element (to enhance the filtering effect), and squeeze to remove excess engine oil.

Reinstall the filter element, filter cover, and maintenance cover in their original positions, and tighten the screws.

Fuel filter inspection:

Unscrew the fuel cap and remove the fuel filter from the fuel tank (pull it out directly by hand).

Pour out the fuel and impurities from the filter, and blow the filter screen from the outside to the inside with compressed air (or rinse with clean gasoline).

Check the filter screen for any damage or blockage, and reinstall it into the fuel tank (ensuring complete insertion).

Every 100 hours/6 months

Spark plug cleaning:

Open the spark plug inspection cover on the left side of the body and remove the spark plug cap (pull vertically upwards with force to avoid damage from side pulling).

Clean the dust and oil around the spark plug with a cloth, and use a spark plug socket wrench to unscrew the spark plug counterclockwise.

Check the spark plug: there are no cracks in the insulator and no excessive wear on the electrode; If there is carbon deposition, clean the electrode with a wire brush.

Adjust spark plug gap: Measure with a plug gauge, the gap is 0.6-0.7mm, and adjust by bending the grounding electrode.

Reinstall spark plug: Tighten clockwise by hand until it fits the cylinder head, then use a wrench to tighten (old spark plug by 1/8-1/4 turn, new spark plug by 1/2 turn, torque not exceeding 12Nm).

Insert the spark plug cap back in place, ensuring it is fully engaged, and close the maintenance cover.

Spark Arrester Cleaning:

Unscrew the 8 screws on the left muffler maintenance cover of the body and remove the maintenance cover.

Loosen the spark arrester clamp screw counterclockwise and remove the clamp and spark arrester filter.

Use a wire brush to remove carbon deposits and debris from the surface of the filter screen. If the filter screen is damaged or has holes, it needs to be replaced.

Reinstall the filter screen and clamp in place, tighten the screws, and reinstall the inspection cover.

Every 250 hours/1 year

Oil change (as before).

Spark plug replacement: Replace with recommended models (Torch A5RTC, NGK CR5HSA, etc.), and check the clearance before installing the new spark plug.

Fuel system cleaning:

Drain the fuel tank, remove the fuel filter, and thoroughly clean it.

Check the fuel pipeline for aging and leaks, and replace it if necessary.

Valve clearance inspection (professional maintenance): Operated by certified technicians or authorized dealers, adjust the valve clearance to the standard range (to avoid damaging the engine by self operation).

3. Long term storage and maintenance (over 3 months)

Preparation before storage:

Clean the surface of the generator, remove dust, oil stains, and debris.

Drain fuel:

Unscrew the fuel cap, remove the fuel filter, and use a siphon pump or directly pour out the fuel from the tank.

Open the fuel emission inspection cover (Phillips screwdriver), loosen the fuel emission screw (Phillips screwdriver), drain the residual fuel in the fuel pipeline, then tighten the emission screw and reinstall the inspection cover.

Reinstall the fuel filter and fuel cap, and close the fuel cap vent.

Oil change: According to the oil change process, drain the old oil and add new oil (400mL).

Anti rust treatment of cylinder:

Remove the spark plug and inject 1 tablespoon of new engine oil into the cylinder.

Pull the recoil starter handle 3-5 times by hand (without inserting the spark plug) to evenly distribute the engine oil on the cylinder wall.

Reinstall the spark plug and pull the starter lever until you feel an increase in resistance (piston in compression stroke, valve closed).

Cover with a dust cover and place in a dry, ventilated, and cool room (do not store in areas with flammable materials).

After storage, remove and use:

Remove the dust cover and check the appearance of the generator for any damage or debris.

Check the oil level of the machine and replenish it if it is insufficient.

Add fresh fuel (do not use fuel that has been stored for too long).

According to the normal start-up process, the engine may emit smoke for a short period of time (residual oil in the cylinder), which is a normal phenomenon and will disappear after running for 1 minute.

4. Maintain taboos and precautions

Do not use flammable solvents such as fuel or banana oil to clean components (such as air filters and machine bodies) to avoid causing fires.

Mixing different brands and models of engine oil is prohibited, and the use of two-stroke engine oil or inferior engine oil is also prohibited.

When replacing spark plugs, the recommended model must be used and the tightening torque should not be too high (to avoid damaging the cylinder head threads).

When cleaning the air filter, do not twist or tear the foam filter element, otherwise the filtering effect will be reduced.

After all maintenance operations, it is necessary to ensure that the components are securely installed and the screws are tightened to avoid detachment during operation.


Deep troubleshooting of common faults (including causes and solutions)

Possible causes of malfunction, troubleshooting steps, and solutions

The engine cannot start. 1. Insufficient oil (low oil protection); 2. Fuel depletion or deterioration; 3. The position of the air damper is incorrect; 4. Spark plug malfunction (carbon buildup, improper clearance, damage); 5. The fuel control switch is not turned on; 6. The fuel cap vent is closed; 7. Air filter blockage 1. Check the oil level of the machine and replenish it to the standard; 2. Check the fuel gauge and add fresh fuel; 3. Confirm the position of the air damper (cold engine START, hot engine RUN); 4. Remove the spark plug and check its condition; 5. Confirm that the fuel control switch is in the ON position; 6. Open the fuel cap vent; 7. Check if the air filter is clogged. 1. Add engine oil; 2. Replace with fresh fuel; 3. Adjust the position of the air damper; 4. Clean spark plugs, adjust clearances, or replace with new spark plugs; 5. Switch the fuel control switch to ON; 6. Unscrew the fuel cap vent; 7. Clean or replace the air filter

Stop the engine immediately after starting. 1. Insufficient engine oil; 2. Fuel pipeline blockage; 3. The air damper has not been adjusted; 4. The load is not disconnected. 1. Check if the low fuel alarm light is on; 2. Check for blockages in the fuel filter and fuel pipelines; 3. Confirm whether the choke is in the RUN position; 4. Check if there is a load connection. 1. Add engine oil; 2. Clean the fuel filter and unclog the pipeline; 3. Adjust the air damper to the RUN position; 4. Disconnect all loads and start with no load

There is engine noise but no AC output. 1. Failure to reset after overload or short circuit; 2. Output indicator light malfunction; 3. Internal malfunction of the generator; 4. Load device failure: 1. Check if the overload alarm light is on and press the reset button; 2. Replace known normal equipment for testing; 3. Turn off the generator and wait for 5 minutes before restarting (ECO mode OFF); 4. If there is still no output, check the inside of the generator. 1. Disconnect the overload load and press the reset button; 2. Replace the load equipment; 3. Restart the generator; 4. Contact authorized dealers for repairs

DC no output 1. Poor socket contact; 2. Load exceeding the standard; 3. DC line fault: 1. Re plug and unplug the DC plug to ensure it is securely fastened; 2. Check if the load power exceeds 100W; 3. Turn off the generator and check if the DC line is damaged. 1. Ensure that the plug is in good contact; 2. Reduce the load to within 100W; 3. Repair or replace the damaged circuit. If the circuit is normal, contact the repair team for assistance

The engine runs unstably and shakes. 1. The fuel deteriorates or contains moisture; 2. The air filter is clogged; 3. Spark plug carbon deposition; 4. Excessive load fluctuations; 5. The throttle valve is dirty. 1. Check the fuel condition and observe whether there is moisture (stratification phenomenon) in the fuel tank; 2. Check the air filter; 3. Clean the spark plug; 4. Check if the load starts and stops frequently; 5. Check if the throttle valve is dirty. 1. Drain the deteriorated fuel and add fresh fuel; 2. Clean the air filter; 3. Clean or replace spark plugs; 4. Stabilize the load and avoid frequent switching; 5. Clean the throttle valve (professional operation)

Abnormal noise during operation: 1. Loose spark plug; 2. Wear and tear of internal engine components; 3. Malfunction of the cooling fan; 4. Loose components 1. Check if the spark plug is tightened; 2. Listen to the source of abnormal noise (cylinder, fan, body); 3. Check if the cooling fan is rotating normally; 4. Check for loose screws and components on the body. 1. Tighten the spark plug; 2. Immediately shut down the machine and contact an authorized dealer for maintenance; 3. Repair or replace the cooling fan; 4. Tighten loose screws and components

Fuel consumption is too fast. 1. ECO mode is not turned on; 2. Excessive load; 3. The engine speed is too high; 4. Fuel leakage: 1. Check if the ECO mode is in the ON position (under low load); 2. Check if the load power is close to the rated power; 3. Observe whether the instrument speed is abnormally high; 4. Check for leaks in the fuel pipeline and fuel tank. 1. Activate ECO mode under low load; 2. Reduce the load and avoid long-term full load operation; 3. Check if the throttle valve is stuck and contact for repair; 4. Repair the leaking area and replenish fuel

image.png

  • ABB TU811 Compact Module Terminal Unit
  • ABB REM610C55HCNN02 motor protection relay
  • ABB IMRIO02 Remote Input/Output Module
  • ABB PFEA113-20 3BSE050092R0 Tension Electronic Equipment
  • ABB UFC911B108 3BHE037864R0108 communication interface
  • ABB REU615E_D Voltage Protection and Control Relay
  • ABB PPD512A10-150000 Controller
  • ABB 5SHX1445H0001 3BHL0000391P0101 3BHB003230R0101 5SXE05-0152 module
  • ABB ICST08A9 Modular Controller
  • ABB 1SVR011718R2500 Analog Converter
  • ABB TB807 3BSE008538R1 module bus terminator
  • ABB PM511 processor module
  • ABB PP877 3BSE069272R2 Industrial Touch Screen
  • ABB EasyLine EL3020 Continuous Gas Analyzer
  • ABB PFEA111 series optical discs
  • ABB DSTD150 I/O connection terminal unit
  • ABB AO801 Analog Output Module
  • ABB PM866 controller
  • ABB 408368B IAM module
  • ABB 3HAC025562-001/06 capacitor unit
  • ABB IEPAS02 power module
  • ABB MSR04X1 serial communication module
  • ABB ICSI16E1 Digital Input Module
  • ABB 3HAC026271-001/DSQC646 Robot Drive
  • ABB SPBRC400 PLC module/rack
  • ABB DSQC355A Analog Input/Output Module
  • ABB PFEA111-65 Tension Controller
  • ABB PM645B processor module
  • ABB FS450R12KE3/AGDR-71C driver combination
  • ABB D2D146-AA28-28 fan
  • ABB PPD513A0E110110 3BHE039724R0E41 Controller
  • ABB PFVO102 PFVO142 3BSE023732R1 Controller Module
  • ABB XFD213A 3BHE02812R0001 Speed Sensor Interface
  • ABB 560PSU02 1KGT011900R0001 power supply device
  • ABB 4LA41100102V1.2 KB2 Broken Board Detector
  • ABB 3BHE023784R1023 PP D113 B01-10-150000 Controller Module
  • ABB 3BHE02294R0103 GFD233A103 Multi functional Control Machine
  • ABB 500MBA02 1MRB150003R003 1MRB200053/M Controller Module
  • ABB 500MBA02 1MRB150003R000/B drive module
  • ABB 500MBA01 1MRB150003R002 1MRB200053/L control card
  • ABB CH-3185 3BHL000986P1006 Controller
  • ABB 969.105EBG 540KKS166899 Controller
  • ABB WE-73-10/CH 64421956 THYRISTOR MODUL
  • ABB 12556917-738385 RADOX GKW cable
  • ABB AF400-30 contactor
  • ABB 103.32125AF 8431160021 connector
  • ABB MTA025 EBG92026 motor terminal adapter
  • ABB 3BHE034863R001 UDC920BE01 Analog Input Module
  • ABB 3BHB009175R0001 Automation Module
  • ABB 3BHB004791R0101 Controller Module
  • ABB HIES208441R interface module
  • ABB SCYC51220 multi-channel pulse trigger board
  • ABB SCYC51213 63911607C multi-channel pulse trigger board
  • ABB SCYC51204 63912476 Transient Absorber Module
  • ABB SCYC51204 63912476C Advanced Pulse Trigger Board
  • ABB TNR 25590 TNR25590 Thermal Overload Relay
  • ABB KTS 011 KTS011 Compact Thermostat
  • ABB KTO 011 KTO011 Compact DIN Rail Thermostat
  • ABB B09261 Electronic Motor Protection Relay
  • ABB LT2005-S/SP19 Programmable Logic Controller
  • ABB RM602024 intermediate relay
  • ABB RM302024 Relay
  • ABB GRBTU-01 3BSE01317R1 DC motor inverter module
  • ABB SZ4127.000 door switch
  • ABB CT-APS.22 1SVR630180R3300 Controller
  • ABB NTAC-02 58967441E pulse encoder
  • ABB BN5930 safety relay
  • ABB UAC389 HIEE410506P104 Industrial Automation Controller
  • ABB UFC921A 3BHE024856P201 industrial control module
  • ABB XVC724BE102 3BHE009017R0102 circuit board
  • ABB LDMUI-01 61320946 High Performance LD MU I/O Module
  • ABB 704.910.4 contact block strip
  • ABB 704.910.5 position switch
  • ABB IEC/EN 60947 contactor
  • ABB E-UK terminal fixing components
  • ABB DIL EM-01-G contactor
  • ABB 90.21 relay
  • ABB 55.34.9.024.0040 Timer Relay
  • ABB 60.13.9.024.0040 power relay
  • ABB KD2406PTBX 24V DC terminal block module
  • ABB PS201PRE fuse module
  • ABB ZM-16-PKZ2 contactor
  • ABB PKZMO-10-T motor protection circuit breaker
  • ABB ZM-40-PKZ2 motor protection stroke block
  • ABB FAZ-C6/1 Miniature circuit breaker
  • ABB FAZ-C10/1 miniature circuit breaker
  • ABB FAZ-C2/1 Circuit Breaker
  • ABB FAZ-C2/2-DC Circuit Breaker
  • ABB FAZ-XHIN11 auxiliary contact equipment
  • ABB Z-NTS neutral wire circuit breaker
  • ABB M3V4-1/0-0 64122088 Input/Output Module
  • ABB NDBU-95C 64008366D control module
  • ABB LWN2660-6EG Automation Control Module
  • ABB LWN2660-6E power supply
  • ABB FPX86-9377-A capacitor
  • ABB MR627 P89627-0-2333400-300-401-601-701 Motor Control Unit
  • ABB 57619414 A 1/2 connector module
  • ABB 57619414 A 2/2 connector module
  • ABB LDMTR-01 63940135F Input/Output (I/O) Module
  • ABB LDSTA-01 63940143B Input/Output (I/O) Module
  • ABB CRBX01 2VAA008424R1 Remote Bus Expander
  • ABB UNITRAL1010 3BHE035301R1002 UNS 0121A-Z, V1 high-performance excitation controller
  • ABB UNITRAL1010 3BHE035301R0001 UNS 0121 A-Z, V1 brushless excitation system
  • ABB CHBX01R 2VAA008575R1 Compact Bus Expander
  • ABB CHBX01L 2VAA008574R1 Bus Expander
  • ABB RMU610 2VAA008425R1 redundant communication module
  • ABB 3BUS208796-501 Communication Module
  • ABB 128057-204 086345-504 multifunctional module
  • ABB HIEE205014R1 HI220856-312/20 UNC4673AV1 redundant controller
  • ABB PP882 3BSE069275R1 Control Panel
  • ABB AC800M PM891 3BSE053240R1 Controller Module
  • ABB AC900F PM904F 3BDH0001002R0001 Controller
  • ABB P8151B communication interface module
  • ABB P8403C controller module
  • ABB P8431 controller module
  • ABB Y129740-002 Analog Module
  • ABB PFTL201D 100KN 3BSE008922R0100 Tension Sensor
  • ABB PPD117A3011 3BHE030410R3011 Excitation Controller
  • ABB PPD512A10-454000 3BHE040375R103E Static Excitation System Unit Module
  • ABB 3BHE046836R0101 GFD563A101 Interface Module
  • ABB 3BHE023784R2530 PPD113B01-25-111000 Controller Module
  • ABB PFCL201CE 50KN 3BSX802939-108 Tension Controller
  • ABB LS4000 diode laser analyzer
  • ABB REM615 HBMBCCAHNB1NN1XD Motor Protection Control
  • ABB 3BHE017628R0002 PPD115A02 SG579989013 Controller Module
  • ABB G2000A5.7ST human-machine interface
  • ABB DKTFM418B 3BHB015651P0001 Controller
  • ABB 3BHE039724R0C3D PPD513 A0C-100440 AC800PEC Controller