Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Westinghouse 2400i digital inverter generator

F: | Au:FAN | DA:2025-11-13 | 669 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Westinghouse 2400i digital inverter generator

Detailed explanation of core product information

1. In depth analysis of technical parameters

Category parameter details note explanation

The engine system has a single cylinder four stroke overhead valve (OHV), and the air-cooled OHV design improves combustion efficiency and extends engine life; Air cooled structure simplifies maintenance and adapts to complex outdoor environments

Power parameters: displacement of 79cm ³, maximum speed of 5000rpm, intelligent adjustment of speed with load (operating at the lowest speed in ECO mode)

Oil specification: The oil capacity is 400mL. It is recommended to use SAE 15W-40 API SG grade for ambient temperatures greater than 40 ℃, and 10W-30 for temperatures ≤ 40 ℃; It is strictly prohibited to mix different types of engine oil

Unleaded gasoline (91 octane and above) for the fuel system, with an ethanol content of ≤ 10%. If the ethanol content in the 5.0L fuel tank is too high, it is easy to cause corrosion of the fuel system. It is recommended to prioritize the use of ethanol free gasoline; Under full fuel condition, ECO mode can run for 8-10 hours

AC output 240V/50Hz, continuous power 2100W, starting power 2400W pure sine wave output, total harmonic distortion<3%, suitable for sensitive equipment such as computers and precision instruments

DC output 12V, maximum current 8A, maximum power 100W. The output is non regulated to avoid connecting devices that are sensitive to voltage fluctuations (such as precision electronic devices)

The protection level of the socket is IP44, which can resist splashing water but cannot be exposed to rain or soaking

Physical characteristics: length 500mm x width 340mm x height 440mm, dry weight 20kg. The handle design is convenient for single person short distance transportation, and the wet weight includes the weight of engine oil and fuel

2. Complete analysis of control panel functions

Component Name Function Description Operation Points

240V AC 15A socket (2 sockets) outputs 240V AC power, with a maximum load of 2400W per socket. When inserting the plug, it needs to be fully pushed in and the waterproof cover should be closed after use

Press and hold the engine stop button to stop the engine. In emergency situations, it can be used directly. Normal shutdown requires disconnecting the load first and running without load for 1 minute before operation

After the reset button of the generator is overloaded or short circuited, after troubleshooting, it is necessary to ensure that the load does not exceed the standard before resetting the AC output, otherwise the protection will be triggered again

ECO throttle switch ON: energy-saving mode, OFF: standard mode. ECO mode is used for small loads (<1000W), and standard mode is used for large loads (>1500W) or inductive loads

Throttle knob START (cold start), RUN (hot run) After starting the cold engine, preheat the engine for 3-5 minutes before pushing it to the RUN position to avoid stuffiness

Multi functional VST instrument displays voltage, speed, and cumulative running time. Press the panel button to switch display modes, and the backlight can be illuminated in low light environments

Fuel control switch ON (run), OFF (stop) should be turned to OFF for long-term storage, and the machine should be stopped after running out of fuel

The low oil warning light (red) lights up when the oil level is too low, and the engine automatically shuts down. It needs to be refilled with oil to the standard level before restarting

Overload alarm light (red) lights up when the load exceeds the standard or short circuit occurs. To cut off the AC output, the load needs to be reduced or the short circuit fault needs to be eliminated before resetting

Output indicator light (green) lights up when the engine is running and the AC output is normal. The green light does not light up but the engine is running. It is necessary to troubleshoot the output fault

Connect the grounding terminal to the ground wire to enhance electrical safety. It is recommended to ground when outdoors in humid environments or when connecting metal enclosed equipment

12V DC socket outputs 12V DC power, compatible with cigarette lighter plug. Do not insert into car cigarette lighter (high temperature can easily cause fire)

3. Function and position of core components

Air filter: located on the right side of the body, filters dust from the intake air to prevent engine cylinder wear; Regular cleaning is required, and the cycle should be shortened in dusty environments.

Spark plug: located on the left side of the body, it generates an electric spark to ignite the fuel mixture; Carbon deposition or wear can cause difficulty in starting and unstable operation.

Spark arrester: installed at the outlet of the muffler to prevent sparks from escaping and causing fires; When used in outdoor or dry environments, it is necessary to ensure cleanliness and smoothness.

Fuel filter: located below the fuel inlet inside the fuel tank, filters impurities in the fuel to avoid clogging the fuel injectors.

Oil inspection cover: on the left side of the body, open to check or add oil; The oil filling port is threaded, so avoid over tightening and damaging the threads when tightening.

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit