Cheryl A. Gayheart Regulatory Affairs Director

来源: | 作者:佚名 | 发布时间 :2023-11-13 | 458 次浏览: | Share:

Docket Nos.: 50-424 NL-21-0444

50-425

U. S. Nuclear Regulatory Commission

ATTN: Document Control Desk

Washington, D. C. 20555-0001

Southern Nuclear Operating Company

Vogtle Electric Generating Plant – Units 1 and 2

Supplement to License Amendment Request to Revise

Technical Specification 3.3.5.2 Allowable Values

Ladies and Gentlemen:

On March 30, 2021 (ML21089A388), pursuant to the provisions Section 50.90 of Title 10 Code

of Federal Regulations (CFR), Southern Nuclear Operating Company (SNC) requested a

license amendment to Vogtle Electric Generating Plant (VEGP) Unit 1 renewed operating

license NFP-68 and Unit 2 renewed operating license NFP-81. The proposed amendment

revises Technical Specification (TS) 3.3.5, “Loss of Power (LOP) Instrumentation”, Surveillance

Requirement (SR) 3.3.5.2 Allowable Values.

On April 19, 2021 (ML21095A087), the U.S. Nuclear Regulatory Commission (NRC) staff

provided the results of their acceptance review and concluded that technical information was not

provided in sufficient detail to enable the NRC staff to complete its detailed review. In order to

make the application complete, the NRC staff requested that SNC supplement the application

by May 6, 2021.

SNC’s response is provided in the Enclosure.

SNC requests the same approval and implementation schedule as requested in its original

application.

The conclusions of the No Significant Hazards Consideration Determination Analysis and

Environmental Consideration contained in the original application have been reviewed and are

unaffected by this supplement.

This letter contains no NRC commitments. If you have any questions, please contact Jamie

Coleman at 205.992.6611

SNC Response to NRC Request for Supplemental Information

E-1

NRC Request to Supplement

The NRC staff identified that the following information is needed, within 13

working days from the date of this letter, to begin its detailed technical review:

 The as-found tolerance (AFT) and as-left tolerance (ALT) values of the

nominal trip setpoint (NTS) calibrations.

 The potential transformer ratio (for voltage conversion from the

transformer’s primary winding to secondary winding).

 Verification of (a) the current Analytical Limits (ALs) of the 4.16 kV

Engineered Safety Features (ESF) Bus LOP Instrumentation are 2912 V

(Loss of Voltage) and 3683 V (Degraded Voltage), and (b) these ALs are

not changed in the calculation.

The NRC staff identified the following information as a request of additional

information (RAI) which should be provided with the supplemental information

requested for acceptance. If this information cannot be provided, please provide

a date when it will be available:

 The full model numbers and the vendor (ABB) datasheets of the affected

relays, including the relays’ applicable pickup and dropout voltages and

performance tolerances. Also, discuss whether a harmonic filter will be

used, which could affect the repeatability versus temperature range

uncertainty.

 The full model numbers and the vendor datasheets of the voltage-tocurrent

module and the analog-to-digital module, including the uncertainty

values of these devices.

The NRC staff needs the above information to begin its detailed technical review

and perform an independent verification of the allowable values for the LOV and

DV relays’ trip setpoints.

SNC Response to NRC Request for Supplemental Information

E-2

of the sensing transformer. Using the sensing transformer ratio of 35:1, the

AFT and ALT Values on the 4160 Volt side of the sensing transformer is

equal to +/- 0.30 Volts x 35. The Loss of Voltage AFT and ALT Values are

+/- 10.5 Volts about the NTS of 2975 Volts.

 The winding ratio of the sensing potential transformer is 35:1.

 The Analytical Limit (AL) for Degraded Voltage is 3683V and for LOP is

2912V. The ALs have not changed in the calculation.

 There are not any physical bistable relays. They are modeled in software.

The pickup and dropout voltages are the ‘Setpoint’ and ‘Reset’ values. The

values and tolerances on the 120 Volt side of the sensing transformer for

degraded voltage and loss of voltage are listed below. A harmonic filter is not

needed because there aren’t any physical relay contacts opening and closing

and generating harmonics when doing so. There is an analog low pass

prefilter and a digital low pass filter built into the analog-to-digital module

(ABB AI620).

Degraded Voltage:

Setpoint (pickup) = 107.03V Hi Limit = 107.33V Low Limit = 106.73V

Reset (dropout) = 108.53V Hi Limit = 108.83V Low Limit = 108.23V

Loss of Voltage:

Setpoint (pickup) = 85.00V Hi Limit = 85.30V Low Limit = 84.70V

Reset (dropout) = 86.50V Hi Limit = 86.80V Low Limit = 86.20V

 The Dataforth voltage-to-current module part number supplied by

Westinghouse is DSCA33-1566. The accuracy data for this Westinghouse

part number is the same as the non-proprietary accuracy data for Dataforth

part number DSCA33-04C. The non-proprietary data sheet for Dataforth part

number DCCA33-04C is provided as Attachment 1 to this Enclosure. The

ABB analog-to-digital module part number is Al620. The non-proprietary data

sheet for the ABB part number AI620 is provided as Attachment 2 to this

Enclosure.


Features

• Interfaces RMS Voltage (0 – 300V) or

RMS Current (0 – 5A)

• Designed for Standard Operation with

Frequencies of 45Hz to 1000Hz

(Extended Range Operation to 20kHz)

  • FOXBORO L0130AD L0130AE-0H Digital Input Module
  • FOXBORO 0399085B 0303440C+0303458A combination control module
  • FOXBORO SY-0399095E SY-0303451D+SY-0303460E DC power module
  • FOXBORO 0399071D 0303440C+0303443B Combination Control Board
  • FOXBORO RH924UQ controller module
  • FOXBORO E69F-TI2-S dual line temperature transmitter
  • FOXBORO 0399144 SY-0301059F SY-1025115C/SY-1025120E Combination Control Board
  • FOXBORO SY-60399001R SY-60301001RB SY-60702001RA/SY-61025006RA/SY-61025004RA/SY-61025001RA High performance industrial control module
  • FOXBORO 0399143 SY-0301060R SY-1025115C/SY-1025120E Sensor
  • FOXBORO 873EC-JIPFGZ Industrial Control Module
  • FOXBORO FBM230 P0926GU Communication Module
  • FOXBORO P0916PH P0916JS Input/Output Module
  • FOXBORO P0916PH P0916AL I/O module
  • FOXBORO 870ITEC-AYFNZ-7 Intelligent Electrochemical Transmitter
  • FOXBORO FBM207 P0914TD Voltage Monitor
  • FOXBORO FBM201D Discrete Input Module
  • FOXBORO P0923ZJ switch I/O interface module
  • FOXBORO P0923NG Intelligent Differential Pressure Transmitter
  • FOXBORO P0916KN power module
  • FOXBORO P0916KM I/A series module
  • FOXBORO P0916WE Terminal Cable
  • FOXBORO P0916VB power supply module
  • GE Hydran M2-X Transformer Condition Monitoring Device
  • FOXBORO P0916VL control module
  • FOXBORO P0916VC High Performance Terminal Cable
  • FOXBORO P0916WG system module
  • FOXBORO P0972ZQ interface channel isolation 8-input module
  • FOXBORO P0973BU high-frequency fiber optic jumper
  • FOXBORO P0926MX Splasher Confluencer
  • FOXBORO P0961S connector module
  • FOXBORO P0903NU system module
  • FOXBORO CM902WM control module
  • FOXBORO P0972VA ATS Processor Module
  • FOXBORO P0916Js digital input terminal module
  • FOXBORO PO961BC/CP40B control module
  • FOXBORO PO916JS Input/Output Module
  • FOXBORO PO911SM Compact Monitoring Module
  • FOXBORO P0972PP-NCNI Network Interface Module
  • FOXBORO P0971XU Control System Module
  • FOXBORO P0971DP Controller
  • FOXBORO P0970VB control module
  • FOXBORO P0970BP (internal) cable assembly
  • FOXBORO P0961EF-CP30B High Performance Digital Output Module
  • FOXBORO P0961CA fiber optic LAN module
  • FOXBORO P0926TM Modular I/O PLC Module
  • FOXBORO P0916BX series control system input/output module
  • FOXBORO P0916AG Compression Period Component
  • FOXBORO P0916AC I/A series module
  • FOXBORO P0912CB I/O Terminal Module
  • FOXBORO P0911VJ high-precision control module
  • FOXBORO P0911QC-C 8-channel isolated output module
  • FOXBORO P0911QB-C High Performance Industrial Module
  • FOXBORO P0903ZP Embedded System Debugging Module
  • FOXBORO P0903ZN control module
  • FOXBORO P0903ZL High Frequency Industrial Module
  • FOXBORO P0903ZE I/A series fieldbus isolation module
  • FOXBORO P0903NW Industrial Control Module
  • FOXBORO P0903NQ control module
  • FOXBORO P0903AA Industrial Control Module
  • FOXBORO FBM205 cable
  • FOXOBORO P0960HA I/A series gateway processor
  • FOXBORO P0926TP high-performance control module
  • FOXBORO P0926KL control module
  • FOXBORO P0926KK PLC system functional module
  • FOXBORO P0924AW wireless pressure transmitter
  • FOXBORO P0916NK differential pressure transmission cable
  • FOXBORO P0916JQ PLC module
  • FOXBORO P0916JP I/A series control module
  • FOXBORO P0916GG Digital Input Module
  • FOXBORO P0916DV I/A series digital input module
  • FOXBORO P0916DC Terminal Cable
  • FOXBORO P0916DB I/A series PLC module
  • FOXBORO P0914ZM recognition module
  • FOXBORO P0902YU control module
  • FOXBORO P0901XT Process Control Unit
  • FOXBORO P0800DV fieldbus extension cable
  • FOXBORO P0800DG Standard Communication Protocol Module
  • FOXBORO P0800DB Universal I/O Module
  • FOXBORO P0800DA Industrial Control Module
  • FOXBORO P0800CE control module
  • FOXBORO P0700TT Embedded System
  • FOXBORO P0500WX Control System Module
  • FOXBORO P0500RY Terminal Cable Assembly
  • FOXBORO P0500RU control module
  • FOXBORO P0500RG Terminal Cable
  • FOXBORO P0400ZG Node Bus NBI Interface Module
  • FOXBORO P0400GH fieldbus power module
  • FOXBORO FBM207B Voltage Monitoring/Contact Induction Input Module
  • FOXBORO FBM205 Input/Output Interface Module
  • FOXBORO FBM18 Industrial Controller Module
  • FOXBORO FBM12 Input/Output Module
  • FOXBORO FBM10 Modular Control System
  • FOXBORO FBM07 Analog/Digital Interface Module
  • FOXBORO FBM05 redundant analog input module
  • FOXBORO FBM02 thermocouple/MV input module
  • FOXBORO FBI10E fieldbus isolator
  • FOXBORO DNBT P0971WV Dual Node Bus Module
  • FOXBORO CP30 Control Processor
  • FOXBORO CM902WX Communication Processor
  • FOXBORO AD202MW Analog Output Module
  • FOXBORO 14A-FR Configuration and Process Integration Module
  • FOXOBORO 130K-N4-LLPF Controller
  • FUJI FVR004G5B-2 Variable Frequency Drive
  • FUJI FVR008E7S-2 High Efficiency Industrial Inverter
  • FUJI FVR008E7S-2UX AC driver module
  • FUJI RPXD2150-1T Voltage Regulator
  • FUJI NP1PU-048E Programmable Logic Control Module
  • FUJI NP1S-22 power module
  • FUJI NP1AYH4I-MR PLC module/rack
  • FUJI NP1BS-06/08 Programmable Controller
  • FUJI NP1X3206-A Digital Input Module
  • FUJI NP1Y16R-08 Digital Output Module
  • FUJI NP1Y32T09P1 high-speed output module
  • FUJI NP1BS-08 Base Plate​
  • FUJI A50L-2001-0232 power module
  • FUJI A50L-001-0266 # N Programmable Logic Control Module
  • GE GALIL DMC9940 Advanced Motion Controller
  • GE DMC-9940 Industrial Motion Control Card
  • GE IS200AEADH4A 109W3660P001 Input Terminal Board
  • GE IC660HHM501 Portable Genius I/O Diagnostic Display
  • GE VMIVME 4140-000 Analog Output Board
  • GE VMIVME 2540-300 Intelligent Counter
  • GE F650NFLF2G5HIP6E repeater
  • GE QPJ-SBR-201 Circuit Breaker Module
  • GE IC200CHS022E Compact I/O Carrier Module
  • GE IC695PSD140A Input Power Module
  • GE IC695CHS016-CA Backboard
  • GE IC800SS1228R02-CE Motor Controller