Cheryl A. Gayheart Regulatory Affairs Director

F: | Au:佚名 | DA:2023-11-13 | 739 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Docket Nos.: 50-424 NL-21-0444

50-425

U. S. Nuclear Regulatory Commission

ATTN: Document Control Desk

Washington, D. C. 20555-0001

Southern Nuclear Operating Company

Vogtle Electric Generating Plant – Units 1 and 2

Supplement to License Amendment Request to Revise

Technical Specification 3.3.5.2 Allowable Values

Ladies and Gentlemen:

On March 30, 2021 (ML21089A388), pursuant to the provisions Section 50.90 of Title 10 Code

of Federal Regulations (CFR), Southern Nuclear Operating Company (SNC) requested a

license amendment to Vogtle Electric Generating Plant (VEGP) Unit 1 renewed operating

license NFP-68 and Unit 2 renewed operating license NFP-81. The proposed amendment

revises Technical Specification (TS) 3.3.5, “Loss of Power (LOP) Instrumentation”, Surveillance

Requirement (SR) 3.3.5.2 Allowable Values.

On April 19, 2021 (ML21095A087), the U.S. Nuclear Regulatory Commission (NRC) staff

provided the results of their acceptance review and concluded that technical information was not

provided in sufficient detail to enable the NRC staff to complete its detailed review. In order to

make the application complete, the NRC staff requested that SNC supplement the application

by May 6, 2021.

SNC’s response is provided in the Enclosure.

SNC requests the same approval and implementation schedule as requested in its original

application.

The conclusions of the No Significant Hazards Consideration Determination Analysis and

Environmental Consideration contained in the original application have been reviewed and are

unaffected by this supplement.

This letter contains no NRC commitments. If you have any questions, please contact Jamie

Coleman at 205.992.6611

SNC Response to NRC Request for Supplemental Information

E-1

NRC Request to Supplement

The NRC staff identified that the following information is needed, within 13

working days from the date of this letter, to begin its detailed technical review:

 The as-found tolerance (AFT) and as-left tolerance (ALT) values of the

nominal trip setpoint (NTS) calibrations.

 The potential transformer ratio (for voltage conversion from the

transformer’s primary winding to secondary winding).

 Verification of (a) the current Analytical Limits (ALs) of the 4.16 kV

Engineered Safety Features (ESF) Bus LOP Instrumentation are 2912 V

(Loss of Voltage) and 3683 V (Degraded Voltage), and (b) these ALs are

not changed in the calculation.

The NRC staff identified the following information as a request of additional

information (RAI) which should be provided with the supplemental information

requested for acceptance. If this information cannot be provided, please provide

a date when it will be available:

 The full model numbers and the vendor (ABB) datasheets of the affected

relays, including the relays’ applicable pickup and dropout voltages and

performance tolerances. Also, discuss whether a harmonic filter will be

used, which could affect the repeatability versus temperature range

uncertainty.

 The full model numbers and the vendor datasheets of the voltage-tocurrent

module and the analog-to-digital module, including the uncertainty

values of these devices.

The NRC staff needs the above information to begin its detailed technical review

and perform an independent verification of the allowable values for the LOV and

DV relays’ trip setpoints.

SNC Response to NRC Request for Supplemental Information

E-2

of the sensing transformer. Using the sensing transformer ratio of 35:1, the

AFT and ALT Values on the 4160 Volt side of the sensing transformer is

equal to +/- 0.30 Volts x 35. The Loss of Voltage AFT and ALT Values are

+/- 10.5 Volts about the NTS of 2975 Volts.

 The winding ratio of the sensing potential transformer is 35:1.

 The Analytical Limit (AL) for Degraded Voltage is 3683V and for LOP is

2912V. The ALs have not changed in the calculation.

 There are not any physical bistable relays. They are modeled in software.

The pickup and dropout voltages are the ‘Setpoint’ and ‘Reset’ values. The

values and tolerances on the 120 Volt side of the sensing transformer for

degraded voltage and loss of voltage are listed below. A harmonic filter is not

needed because there aren’t any physical relay contacts opening and closing

and generating harmonics when doing so. There is an analog low pass

prefilter and a digital low pass filter built into the analog-to-digital module

(ABB AI620).

Degraded Voltage:

Setpoint (pickup) = 107.03V Hi Limit = 107.33V Low Limit = 106.73V

Reset (dropout) = 108.53V Hi Limit = 108.83V Low Limit = 108.23V

Loss of Voltage:

Setpoint (pickup) = 85.00V Hi Limit = 85.30V Low Limit = 84.70V

Reset (dropout) = 86.50V Hi Limit = 86.80V Low Limit = 86.20V

 The Dataforth voltage-to-current module part number supplied by

Westinghouse is DSCA33-1566. The accuracy data for this Westinghouse

part number is the same as the non-proprietary accuracy data for Dataforth

part number DSCA33-04C. The non-proprietary data sheet for Dataforth part

number DCCA33-04C is provided as Attachment 1 to this Enclosure. The

ABB analog-to-digital module part number is Al620. The non-proprietary data

sheet for the ABB part number AI620 is provided as Attachment 2 to this

Enclosure.


Features

• Interfaces RMS Voltage (0 – 300V) or

RMS Current (0 – 5A)

• Designed for Standard Operation with

Frequencies of 45Hz to 1000Hz

(Extended Range Operation to 20kHz)

  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module
  • National Instruments 782362-01 Input Module
  • National Instruments 779068-01 Digital Module
  • National Instruments 781063-01 Output Module
  • National Instruments PCI-7356 Motion Controller
  • National Instruments 779787-01 Input Module
  • National Instruments PXIe-1071 System
  • National Instruments NI 9219 Input Module
  • National Instruments NI 9214 Thermocouple Input Module
  • National Instruments PXIe-1085 18-Slot Chassis
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments USB-6211 Multifunction I/O Device
  • National Instruments USB-6341 X Series DAQ Device
  • National Instruments NI 9205 Analog Input Module
  • National Instruments NI 9149 8-Slot Chassis
  • National Instruments PXIe-2569 Relay Module
  • National Instruments NI 9230 Sound and Vibration Module
  • National Instruments cRIO-9047 CompactRIO Controller
  • National Instruments PCI-6534 Digital IO Card
  • National Instruments PXI-5122 Digitizer Module
  • National Instruments cDAQ-9188XT Chassis
  • National Instruments cDAQ-9184 Ethernet Chassis
  • National Instruments USB-6225 OEM DAQ Device
  • National Instruments NI 9205 Input Module
  • National Instruments NI 9207 Input Module
  • National Instruments NI-9862 CAN Module
  • National Instruments 781156-01 CAN Module
  • National Instruments FP-AO-200 Output Module
  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module