Core characteristics of the instrument and panel controls

1. Core characteristics of the instrument

Dual time base generator: including A time base (main time base) and B time base (auxiliary time base), supporting three working modes (independent sweep, dual sweep, delayed sweep).

Scanning speed range:

A time base: 1 μ s/Div to 5s/Div (21 levels 1-2-5 sequence), 10x magnification (A SWP MAG) to reach 100ns/Div;

B time base: 0.2 μ s/Div to 0.5s/Div (20 levels 1-2-5 sequence), no amplification function.

Delay function: Set the delay time using the DELAY TIME MULT knob, with a range of 0.2-10.2 times the A time base sweep speed (corresponding to 1 μ s to 50s), for delayed sweep mode.

External signal support: External signals can be connected to replace the A time base display, and the amplifier mode provides two calibration deflection coefficients of 50mV/Div and 0.5V/Div.

2. Key panel controls (function summary)

Control Category Control Name Function Description

Mode control MODE (A/B/dual sweep) - A: Only A time base works, B time base is locked

-B: Only B time base works, A time base is locked

-Dual sweep frequency (A+B pressed): A and B time bases work simultaneously, with time sharing display

A INTEN-B DLY'D Delay Sweep Mode Switch, to be coordinated with A/B buttons:

-Only press A: display A time base, B time base works synchronously (strengthened segment display)

-Only press B: B time base delay start (delay time is determined by A time base and DELAY TIME MULT)

-Press A+B: A time base strengthening segment and B time base delay display

B TRIG AFTER DLY is triggered after a delay in the B time base. It is necessary to first meet the delay time set by the A time base, and then activate the B time base with the trigger signal

Time base control A/B Seconds/DIV selects calibration scanning speed, and the knob skirt lights up to display the current gear (A is a dark gray knob, B is a light gray knob)

A SWP MAG A time base is amplified 10 times, and the scanning speed is directly displayed after amplification (such as 1 μ s/Div → 100ns/Div), with only the central grid area visible

DELAY TIME MULT delay multiple adjustment, range 0.2-10.2 times A time base sweep speed, used to locate the starting point of delayed sweep frequency

A SINGL SWP A Time Base Single Sweep Mode, only triggered once when pressed, requires A RESET reset

A RESET resets the sweep circuit: re standby in single mode, terminate the current sweep in any mode

Trigger Control A/B TRIGGERING Source - LEFT/RIGHT: Select the left/right vertical plugin as the trigger source

-COMPOSITE (exclusive to A): Select the display signal as the trigger source (press A+B)

-LINE: Select the power frequency (50/60Hz) as the trigger source

-EXT (unique to A): Select A EXT INPUT external signal as the trigger source

A/B TRIGGERING COUPLING - AC (pressed): Capacitive coupling, blocking DC, attenuating low frequencies<50Hz

-DC (pop-up): Direct coupling, retaining DC and low-frequency components

A/B TRIGGERING SLOPE -+SLOPE (pressed): Positive slope trigger (signal rising edge starts sweep frequency)

-- SLOPE (pop-up): Negative slope trigger (signal falling edge initiates frequency sweep)

A/B TRIGGERING LEVEL adjusts the trigger level, and the ± region corresponds to the positive and negative voltage points of the signal. Rotate clockwise to increase the trigger level

Status and display READY INDICATOR indicator light, illuminated in A time base single mode to indicate readiness (trigger acceptable)

Display (ALT/CHOP) - ALT (pop-up): alternately displays A/B time base, suitable for fast scanning speed

-CHOP (pressed): Chopper displays A/B time base, suitable for scenarios with slow scanning speed or large scanning speed differences

INTEN BAL balances the brightness of A and B time base trajectories for clear observation or photography in dual sweep mode

image.png

Working mode and operation process

1. Three core working modes

Mode name trigger condition applicable scenario key operation steps

Independent sweep mode (A or B works separately) - Normal trigger (AUTO TRIG pops up): The trigger signal must be ≥ 15Hz and the LEVEL must be correct

-Automatic trigger (AUTO TRIG pressed): Free operation at<15Hz or no trigger (baseline illuminated)

-Single trigger (A SINGL SWP pressed): Only 1 sweep frequency, A RESET is required to reset the regular time measurement of simple signals, non repetitive signal photography 1. Press the A or B button of MODE

2. Choose TRIGGERING SOURCE-COUPLING/SLOPE

3. Adjust LEVEL to stable display, press A RESET for standby in single mode

Dual sweep mode (A+B working simultaneously) A trigger source corresponds to the left vertical plugin, B trigger source corresponds to the right vertical plugin, and trigger parameters need to be set separately to observe two signals (or different scan speeds of the same signal) simultaneously. 1. Press the A+B button of MODE

2. Set the PLAY to ALT (fast scanning speed) or CHOP (slow scanning speed)

3. Adjust the Seconds/DIV and trigger parameters of A/B separately, and use INTERN BAL to balance the brightness

Delay sweep mode (B time base delay start): After triggering A time base, start B time base (or wait for triggering after B time base delay) signal local amplification, time difference measurement, pulse jitter measurement. 1. Press the A INTEN-B DLY'D button of MODE (in conjunction with A/B)

  • Samsung D0C-16C Digital I/O Control Module
  • SAMWONTECH TLC990ME-83 Multi-Channel PID Controller
  • SanDisk SDP3B-10 Industrial Flash Storage
  • SAC IOP351 Advanced Processor
  • SAC IOP331 Input/Output Processor Technical
  • Saftronics EZ6 40 Soft Starter Manual
  • Sagemcom 252720938AB Signal Processor
  • Sagemcom 252721117AC Interface Module
  • Sagemcom 252721013AF Controller
  • SAIA PCD2.W610 Analog Output Module
  • SAIA PCD3.R60X Flash Memory Storage Module
  • SAT RM3141-01-02 CM3141-01-02 System
  • SAT CM3142-01-03 CX3147-04 Overview
  • SAT CM3141-02-03 CX3149-05 Technical Manual
  • Sauter AVM234SF132 Valve Actuator Specs
  • SBS PFSK165 3BSE027778R1 Technical Specs
  • SBS VIPC616 91611524 VME Carrier Board
  • SBS PMC-HS-SERIAL Interface Module
  • Schenck FNT-L001 Network Terminal Guide
  • Schenck VEG20400 Weighing Electronics Specs
  • Schiele DL42N-22 Multi-Function Relay
  • Schiele DL22N-22 Monitoring Relay Specs
  • Schleicher SSY52 Safety Control Unit Manual
  • Schleicher UST21 Control Module
  • SanDisk 336A4940EZP1 Industrial SSD
  • Sankyo PC10021 Industrial Control Module
  • SANMOTION PB3A003P200 Servo Drive
  • Sanyo P30B04010PCKST AC Servo Motor
  • Sanyo STNM-DR-250B Industrial Drive Module
  • Sanyo STNM-DR-160B Mixed I/O Module
  • Sanyo PMDAA1SFC20R Servo Amplifier
  • Sartorius MDB-5E Precision Weighing Module
  • SBS VIPC616 VME-IP Carrier Board
  • SBS 82002070 High-Performance Control Module
  • SBS P2-100BT-ER Industrial Ethernet Module
  • SBS 82002077 Industrial Control Module
  • SCANLAB INTELLISCANDE14-405NM UV Laser Scan Head
  • SCANLAB INTELLISCANDE14-1064NM IR Laser Scan Head
  • SCANLAB INTELLISCANDE III14-532NM Laser Scan Head
  • SCHAFFNER FN3416-110-35 EMI Power Line Filter
  • SCHROFF MPS015 Series
  • SCHROFF MPS015 13100205 Power Supply
  • SCHROFF 3BSC690076R5 Module Review
  • SCHUMACHER ATCS-15 1464-0320 Review
  • SCHUMACHER MDIA-162 System Analysis
  • SCHUMACHER ATCS-15 Technical Guide
  • Schumacher 1442-0010H Industrial Battery Charger Module
  • Seagate ST3630A 3.5 Inch IDE Hard Drive
  • SEC PB5F-DYL Latching Relay Output Module
  • SEC PB5F-DYI Isolated High-Density Output Module
  • SEC PB5F-DY High-Density Digital Output Module
  • SEC PB5-DY 5-Channel Digital Output Module
  • SEC PB4-DYI Isolated Digital Output Module
  • SEC PB4-DY 4-Channel Digital Output Module
  • SECO B161S-E176 Control Card
  • SEF M21.1 Control Module
  • Seidel MV65WKS-CE310/22PB Driver
  • SEM MT30R4-37 Servo Motor
  • SEMIKRON SKD62/16 Rectifier Bridge
  • SENTRON LD63F600 Circuit Breaker
  • Sentry VREL-11 Voltage Relay
  • Servo MTS30M4-38 AC Servo Motor
  • Servo Module SEVO BOARO C20003/2.1 Motion Control Board
  • Servoland SVFH8-H3-DSP*ANI Servo Drive
  • Servotecnica SVT57BL03-60V Brushless Servo Motor
  • SES 2422 Frequency to Analog Converter
  • SES 2409 Thermocouple Signal Conditioner
  • SES 2411 Industrial Signal Conditioner
  • SEW MDV60A0110-5A3-4-00 11kW Drive
  • SEW MPB51A055-503-00 Power Unit
  • SEW 31C055-503-4-00 5.5kW Inverter
  • SEW R37DS56L Geared Motor Specs
  • SEW MDV 8222215.14.17 Power Board
  • SEW MKS51A005-503-50 MOVIKIT Controller
  • SEW MHD093C-058-PG0-AN Synchronous Servo Motor
  • SEW MDV60A0075-5A3-4-0T MOVITRAC Frequency Inverter
  • SEW MDS60A0150-503-4-00 MOVIAXIS Servo Drive
  • SEW MDF60A-0075-5A3-4-00 MOVIFIT Drive
  • SEW MDF60A-0022-5A3-4-00 MDX60A0075-5A3-4-00 Drive System
  • SEW MDF60A-0022-5A3-4-00 MOVIFIT Drive
  • SEW EF-014-503 Braking Resistor
  • SEW DFP11B 8227241.12 Interface
  • SEW DFP 21A PROFIBUS Interface Card
  • SEW 31C450-503-4-00 45kW Inverter
  • SEW 31C075-503-4-00 7.5kW Inverter
  • SEW 31C015-503-4-00 1.5kW Inverter
  • SEW 31C005-503-4-00 Drive Analysis
  • SHINKAWA VM-5G0-2 General Purpose Monitor
  • SHINKAWA VM-5C Shaft Eccentricity Monitor
  • SHINKAWA VM-5Z4 Power Supply Module
  • SHINKAWA VM-5P3 Phase Reference Module
  • SHINKAWA VM-5H3 8-Slot Monitoring Rack
  • SHINKAWA VM-5Y1-02 GEM Process Monitor
  • SHINKAWA VM-5K Dual Vibration Monitor
  • SHINKAWA MP-2W2 Differential Expansion Monitor
  • SHINBORY DENSHI HD-522 Technical Guide
  • SHINKAWA MP-2P1 Industrial Vibration Monitoring Module
  • SHINKAWA MP-2P4 Multi-Channel Vibration Monitoring Module
  • SHINKAWA MP-2S Vibration Monitoring Module
  • SHINKAWA MP-2T Magnetic Pickup
  • SIEBEL IPS21-24V-35AD ABB Module
  • SIEBEL&SCHOLL IPS21-35AD Power Supply
  • SIEGER 05701-A-0550 Control Unit
  • SIEGER 05704-A-0122 Control Card
  • Siemens Moore 16114-171 I/O Module
  • Sigmatek DNC115 Digital I/O Module
  • Silicon Graphics B014ANT180 Graphics Card
  • Silicon Graphics 030-0730-003 VGA Graphics Module
  • SIMCO FMX-003 Electrostatic Field Meter
  • SHINKAWA MP-2S Vibration Monitoring Module
  • SINANO SE04-10WA Servo Driver Info
  • SIS AI3281 Analog Input Module
  • SIS CM01 Communication Module
  • SIS MC01 Main Controller Module
  • SIS DO3201 Digital Output Module
  • SIS DI3201 Digital Input Module
  • SIS BI01 Bridge Input Module
  • SIS PM01 Power Monitor Module
  • SKIIP 39AC12T4V1 IGBT Power Module
  • SLIMPAK 10923H5A Isolated DC-DC Converter
  • SLIMPAK G468-0001 Isolated Signal Conditioner
  • SLIMPAK G408-0001 DC-DC Converter
  • SLO-SYN M063-LE-507E Hybrid Stepper Motor
  • SMC VQ1-LPF04+VQ1100N-5 Valve Assembly
  • SMC INR-244-203B Technical Overview
  • SMC INR-244-97B-B-X5 Cooling System Info
  • SMC MHY2-10D2 Air Gripper
  • SNAP CB:2F:DA 8/4MB Memory Module