Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Basler DECS-200-2L excitation system

F: | Au:FANS | DA:2026-06-11 | 707 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Basler DECS-200-2L excitation system

Product Overview and Technical Specifications

DECS-200-2L is an integrated excitation control system that controls the terminal voltage, reactive power, or power factor by adjusting the DC current of the generator excitation winding. The core parameters are as follows:

1.1 Input power supply

Control power supply (model optional): 16-60Vdc (30W), 85-132Vac 50/60Hz (50VA), 90-150Vdc (30W).

Operating power supply (excitation power): Select single-phase or three-phase input (50-500Hz) according to the required output DC voltage, corresponding to the following relationship:

DECS-200 output AC input voltage (nominal) input range apparent power

32Vdc 60Vac 56~70Vac 780VA

63Vdc 120Vac 100~139Vac 1570VA

125Vdc 240Vac 190~277Vac 3070VA

Attention: When supplying power directly from a power source that has already reached the rated voltage, an ICRM-15 surge current suppression module needs to be installed. The minimum building voltage is 3Vac.

1.2 Output Characteristics

Parameter 32Vdc, 63Vdc, 125Vdc

Rated continuous current 15Alc 15Alc 15Alc

Rated 10 second strong excitation voltage 50Vdc, 100Vdc, 200Vdc

Rated 10 second strong excitation current 30Adc 30Adc 30Adc

Minimum magnetic field resistance 2.13 Ω 4.2 Ω 8.3 Ω

Note: If three-phase input or magnetic field current is significantly lower than the rated value, the strong excitation voltage can be increased by 50%.

1.3 Voltage Transformer Input

Generator voltage transformer: single-phase or three-phase line voltage, with four selectable ranges (100/120V, 200/240V, 400/480V, 500/600V, corresponding to 50/60Hz).

Bus voltage transformer: single-phase line voltage, with the same four ranges.

1.4 Environment and Certification

Working temperature: -40 to+60 ℃; Storage: -40 to+85 ℃.

Anti vibration, anti impact, and salt spray comply with MIL-STD-810E.

Certification UL recognized(File E97035)、CSA certified、CE compliant、DNV、GOST-R、Byelorussian。


Installation and Wiring Guide

2.1 Mechanical dimensions and installation

DECS-200-2L dimensions: width 8.08 inches (205mm) x height 12.0 inches (304mm) x depth 6.76 inches (171mm), weight 14 pounds (6.35kg). Installation using panel opening (see manual figure 5 for opening size) requires the use of a front mounting bracket (Basler P/N 9360107100). You can also choose the IDP-800 remote interactive display panel (7.5-inch color touch screen), which can be installed up to 4000 feet away through RS-485.

2.2 Typical Wiring Diagram

Figure 1 in the manual provides a typical AC connection diagram, with the main wiring including:

Operating power supply: terminals PMG A, B, C (three-phase or single-phase).

Generator voltage detection: terminals P1, P2, P3 (single-phase or three-phase).

Bus voltage detection: terminals S1 and S2 (single-phase).

Excitation output: terminals F+, F -.

Parallel compensation CT: terminals C1 and C2 (cross current).

Switching input: dry contact (requires external supply of 24Vdc), including start stop, up/down, AVR/FCR selection, parallel/single machine switching, alarm reset, etc.

Analog input: Two sets, optional ± 10Vdc or 4-20mA, used for power system stabilizer (PSS) or remote set point.

Communication port:

COM0: RS-232 (front panel), ASCII command, used for local PC connection.

COM1: RS-232 (right side), used for dual machine redundant tracking.

COM2: RS-485 (left side), Modbus protocol, half duplex, 1200-19200bps.

2.3 Special precautions for redundant systems

When using dual DECS-200 redundant applications, an interconnect cable (Basler P/N 931030032) is required to connect the COM1 port.

The excitation output must be connected in parallel to the magnetic field winding through an external contactor, and a flywheel diode module (Basler P/N 9293600101) must be connected in parallel to the outside of the magnetic field winding to provide a continuous current path during switching, avoiding measurement errors or excitation interruptions caused by current interruption.

Operation mode and adjustment function

DECS-200 supports four main adjustment modes, which can be switched through switch input or communication, and has internal automatic tracking (non active mode tracks active mode) to achieve disturbance free switching. Optional external automatic tracking (between two machines).

3.1 Automatic Voltage Regulation (AVR)

AVR is the default mode, maintaining a constant generator terminal voltage with an accuracy of ± 0.25% (from no-load to full load) and a steady-state accuracy of ± 0.1%. Soft start function: The soft start time (1-7200 seconds) can be set, and the voltage smoothly increases from the residual value to the set value during voltage building to avoid voltage overshoot.

3.2 Field Current Regulation (FCR)

FCR is a manual backup channel that directly controls the excitation current with an accuracy of ± 1%. It does not rely on voltage detection, so it can be used as a backup during demagnetization detection. In FCR mode, all limiters (OEL, UEL, SCL) only sound an alarm and do not activate.

3.3 Reactive power regulation (Var)

When the generator is connected to the grid, DECS-200 can adjust the reactive power output to the specified value (kvar) with an accuracy of ± 2% of the rated kVA.

  • National Instruments PXI-8364 MXI-Express Interface
  • National Instruments PXIe-8360 Interface Card
  • National Instruments 196859B-01 Ordering Part Number
  • National Instruments PXIe-1073 5-Slot Chassis
  • National Instruments NI 9209 Voltage Input Module
  • National Instruments USB-5133 Digitizer
  • National Instruments PXI-1044 Chassis
  • National Instruments NI 9266 785046-01 Module
  • National Instruments USB-6216 DAQ Device
  • National Instruments NI 9266 Output Module
  • National Instruments NI 9230 Vibration Module
  • National Instruments PCI-6230 DAQ Card
  • National Instruments PXI-6123 DAQ Card
  • National Instruments PCI-6255 DAQ Card
  • National Instruments PXI-8433 Serial Module
  • National Instruments PXIe-4138 Source Measure Unit
  • National Instruments 781044-01 PCIe-6321 DAQ Part Number
  • National Instruments PXIe-6356 X Series DAQ Module
  • National Instruments PCI-6513 Industrial Digital Output Card
  • National Instruments 183345A-04 Ordering Part Number
  • National Instruments PCIe-6351 X Series DAQ Card
  • National Instruments PXI-4070 FlexDMM Module
  • National Instruments PXI-6225 Multifunction DAQ Module
  • National Instruments 781496-01 Ordering Part Number
  • National Instruments 779592-01 Ordering Part Number
  • National Instruments SCXI-1121 Module
  • National Instruments NI 9148 Chassis
  • National Instruments PXI-6255 DAQ Module
  • National Instruments USB-4065 DMM
  • National Instruments PXI-6221 DAQ Module
  • National Instruments PXIe-1065 Chassis
  • National Instruments NI 9210 Input Module
  • National Instruments 778948-01 Output Module
  • National Instruments cRIO-9014 Controller
  • National Instruments cDAQ-9171 Chassis
  • National Instruments USB-6363 DAQ Device
  • National Instruments NI 9467 GPS Module
  • National Instruments USB-6351 DAQ Device
  • National Instruments NI 6581 Adapter Module
  • National Instruments 781045-01 Output Module
  • National Instruments PCI-6225 DAQ Card
  • National Instruments TRC-8543 CAN Cable
  • National Instruments PXIe-1073 Chassis
  • National Instruments USB-6003 DAQ Device
  • National Instruments NI 9476 Output Module
  • National Instruments myRIO-1900 Embedded Controller
  • National Instruments NI-9263 Analog Output Module
  • National Instruments 158561A-01L Ordering Part Number
  • National Instruments 785024-01 Ordering Part Number
  • National Instruments PCI-6510 Industrial Digital I/O Card
  • National Instruments USB-6259 Multifunction DAQ Device
  • National Instruments USB-8452 I2C SPI Interface Device
  • National Instruments PXI-8432 Serial Interface Module
  • National Instruments PXIe-5644R Vector Signal Transceiver
  • National Instruments PXI-2569 Relay Module
  • National Instruments 781174-01 Module
  • National Instruments 782000-01 Module
  • National Instruments PXI-5152 Digitizer
  • National Instruments PXI-6284 DAQ Card
  • National Instruments PCI-1428 Frame Grabber
  • National Instruments PXI-1050 Chassis
  • National Instruments NI USB-8486 Fieldbus
  • National Instruments NI 9862 CAN Module
  • National Instruments NI 9146 FPGA Chassis
  • National Instruments PXI-8108 Controller
  • National Instruments NI SWB-2816A Matrix Module
  • National Instruments NI 9269 Analog Output Module
  • National Instruments PCI-6031E Multifunction DAQ Card
  • National Instruments PXI-6713 Analog Output Module
  • National Instruments NI 9216 RTD Input Module
  • National Instruments NI-9237 Strain Bridge Input Module
  • National Instruments PXI-5124 High Resolution Digitizer
  • National Instruments USB-6343 X Series DAQ Device
  • National Instruments PXIe-6536 Digital I/O Module
  • National Instruments CAL-4330 Calibration Fixture
  • National Instruments PXI-4110 Programmable Power Supply
  • National Instruments 781503-01 Input Module
  • National Instruments FP-AI-V10 Module
  • National Instruments PXI-5114 Digitizer Card
  • National Instruments PXIe-8398 MXI Module
  • National Instruments cRIO-9056 Controller
  • National Instruments PCI-6509 DIO Device
  • National Instruments cRIO-9053 Controller
  • National Instruments 781056-01 Output Module
  • National Instruments 782606-01 Input Module
  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module