P5X-175:160 A gG/gL

Rated short-time withstand current (1 second): 1125 A rms

Wiring capability: 50-70 mm ² solid wire, or copper strip connection (6 × 9 × 0.8 mm)

3.3 Breaking ability

P5X-125

AC-21A load switch, 440V: 125 A

Motor power (AC-3 load):

230 V:22 kW

400 V:37 kW

690 V:30 kW

Motor power (AC-23A load):

230 V:30 kW

400 V:45 kW

690 V:37 kW

P5X-175

AC-21A load switch, 440V: 160 A

Motor power (AC-3 load):

230 V:30 kW

400 V:45 kW

690 V:37 kW

Motor power (AC-23A load):

230 V:30 kW

400 V:55 kW

690 V:37 kW

3.4 DC application parameters

P5X series (DC-23A load, L/R=15ms)

125A model:

24 V: 125 A (3 contact modules in series)

48 V: 125 A (3 contact modules in series)

60 V: 125 A (3 contact modules in series)

120 V: 40 A (3 contact modules in series)

Model 175A:

24 V: 160 A (3 contact modules in series)

48 V: 160 A (3 contact modules in series)

60 V: 160 A (3 contact modules in series)

120 V: 50 A (3 contact modules in series)

Chapter 4 System Composition and Selection Guide

4.1 Modular System

The TX cam switch and PX load isolation switch adopt modular design, consisting of the following basic components:

Joystick: Provides multiple colors and function options

Switch unit: core on-off component

Contact module: Each module contains 1 or 2 contacts

Install attachments: Implement different installation methods

Emblem: Identify the position and function of the switch

4.2 Installation method

According to application requirements, the following installation methods can be selected:

Characteristics of installation method code

Flat installation.../E front IP65, rear installation and wiring

Center installation.../EZ front IP65, single hole diameter 22.3 installation, card fixed

Rear installation.../Z front IP65, installed from the rear

Surface mount.../11,.../12 front IP65, connected from the front

Installation of distribution cabinet.../IVS installed on the distribution cabinet, depth 45mm

Control screen installation.../VS installed on the control screen

4.3 Flat installation type main switch

Special design for main switch, maintenance switch, and safety isolation:

Model code: ../EA/SVB (flat installation),.../V/SVB (rear installation)

Emblem: Standard FS908 with 0-position padlock function

Handle color:

Red/Yellow: with emergency stop function, compliant with IEC/EN 60204-1

Black/Black: No emergency stop function

Padlock function: Up to 3 padlocks can be added to 0 positions

4.4 Contact module configuration

The contact number of the switch is defined by the standard configuration table and can be selected as needed:

T0X: Up to 11 contact modules (22 contacts), with a single module depth of 9.5mm

T3X: Up to 11 contact modules (22 contacts), with a single module depth of 11.5mm

T5X (B): Up to 10 contact modules (20 contacts), with a single module depth of 16.5mm

P1X/P3X: up to 3 poles+N poles

4.5 Customization of non-standard switches

For applications where standard contact sequences cannot be met, Eaton provides customized non-standard switch services:

Initial customization: The "Cam Switch Customization Model Initial Order Customization Form" (F02 Form) needs to be filled out

Reorder: simply specify the contact number and country identifier (e.g. 4711D)

Customized models: T0X/T3X/T5XB/T5X all have corresponding customized models, and the order number is marked with "- SONG *"


Chapter 5 Detailed Explanation of Main Function Types

5.1 Main switch, maintenance switch/forced manual control switch

Function: As the main power switch of the device, it is used for safety isolation and emergency disconnection.

Features:

Compliant with IEC/EN 60204 and IEC/EN 60947-3 standards

Definitely disconnect the contact, the operating element is rigidly fixed to the spindle

Optional red/yellow handle with emergency stop function

0-position can be equipped with a padlock, which meets the safety requirements of Lock/Tag Out (LOTO)

Typical model:

T0X-1-8200/11/SVB (1-pole, with padlock)

P1X-25/12/SVB (25A, with padlock)

P3X-63/14/SVB (63A, with padlock)

5.2 on-off switch

Function: Used for circuit connection and disconnection, can serve as a main switch or control switch.

Features:

Multiple configurations including 2-pole, 3-pole, 4-pole, etc

Optional with 0 bits or direct on/off

Suitable for load types such as AC-21A and AC-23A

Typical model:

T0X-3-8342/11 (3-pole on-off switch)

T3X-3-8342/12 (3-pole on-off switch)

5.3 Conversion switch

Function: Implement power or load switching, such as switching between primary and backup power sources, star delta startup, etc.

Features:

Switch with 0-position (I-0-II)

Switch without 0 position (I-II)

Can be configured for manual automatic conversion

Typical model:

T0X-1-8210/E (1-pole toggle switch)

T3X-2-8211/12 (2-pole conversion switch)

T0X-3-8212/E (3-pole conversion switch)

5.4 Steering switch

Function: Used for forward and reverse control of electric motors.

Features:

Reversing switch with 0 position (positive 0 reverse)

Directly control the direction of the electric motor

Suitable for lifting, conveying and other equipment

Typical model:

T0X-2-8400/EZ (2-pole reversing switch)

T3X-3-8401/12 (3-pole reversing switch)

5.5 Multi speed switch

Function: Used for speed switching of multi speed motors.

Features:

  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module
  • HIMA H6200A Terminal Module for Safety I/O
  • HIMA Z7130 Power Supply Distribution Module
  • HIMA F8652E 984865264 Central Module HIQuad H51q
  • HIMA F8627 984862702 Communication Module HIQuad System
  • HIMA H41q-HS High-Speed Safety Controller B4237-1 997104237
  • HIMA F8652X Central Processing Unit 984865265
  • HIMA H4135 Safety Logic Solver 992413502
  • HIMA H51q-H High-Integrity Safety Controller B5233-2 997235233
  • HIMA F6217 Safety Controller 984621702
  • HIMA F3330 984333002 Digital Output Module
  • HIMA F7553 984755302 Communication Module
  • HIMA F7131 Power Supply Module
  • HIMA X-DO1201 985210204 Digital Output Module
  • HIMA H51q-HRS B5233-2 Safety Controller Module
  • HIMA F3231 16-Channel Digital Input Module
  • HIMA K9203A (996920360) Safety Relay Module
  • HIMA H51q-HS B5233-1 Safety Control System
  • HIMA F7131 Power Supply Monitoring Module
  • HIMA F8620/11 Central Module for HIQuad Systems
  • HIMA X-FAN 18 03 Redundant Fan Module for Safety Systems
  • HITACHI LYD000A Digital Input Module 8-Channel
  • HITACHI PS6000 Heavy-Duty Power Supply 24VDC 10A