Power Requirements: All models require a power supply capable of delivering 23A (24V DC) with a 2ms start-up inrush current. The input voltage range is 19.2V...31.2V DC, within which the module can operate stably. Taking 1794-ASB/E as an example, the module can still work when the connected power supply voltage is at the lower limit of 19.2V, but if the voltage is continuously lower than this value, the performance may be unstable or even unable to work normally; if the voltage is higher than 31.2V, it may cause damage to the internal circuitry of the module. The output voltage is 5V DC, 640mA, which can provide stable working voltage for the connected FLEX I/O modules.
Communication Rate: 1794-ASB/E, 1794-ASBK/E and 1794-ASB2/D support three communication rates: 57.6Kbps, 115.2Kbps and 230.4Kbps. Users can flexibly choose the appropriate communication rate according to the requirements of real-time data transmission and the quality of the communication line in the actual application scenarios. For example, in the environment of low real-time data transmission requirements and certain interference in the communication line, the rate of 57.6Kbps can be selected to ensure the stability of data transmission; while in the very high real-time requirements, such as some high-speed operation of the equipment monitoring scenarios, you can choose the high speed rate of 230.4Kbps, to ensure that the data is transmitted in a timely and accurate manner.
Indicator Lights: All of them are equipped with power (green), adapter activity (green), adapter failure (red), local failure (red) indicator lights. These indicators provide visual feedback on the module's operating status. When the power indicator lights up green, it indicates that the module has been connected to a normal power supply; the adapter activity indicator flashes green, indicating that the module is carrying out normal data communication activities; if the adapter failure indicator turns red, it means that the module may have internal faults that need to be investigated in a timely manner; and the local fault indicator turns red, suggesting that there may be a problem with the locally-connected device or line.
Dimensions: Dimensions (H x W x D) are 87 x 69 x 69mm (3.4 x 2.7 x 2.7 inches), the compact size makes it easier to install and arrange in control cabinets and other space-limited environments, space-saving, and easy to integrate with other equipment.
Isolation Voltage: Isolation voltage is 50V (continuous), basic insulation type, tested at 750V DC for 60s (between power supply and system, power supply and RIO, RIO and system). This electrical isolation design effectively prevents electrical interference between different circuits, protects the module and connected devices from electrical shocks and interference, improves the stability and reliability of system operation, and ensures safe operation in complex industrial electrical environments.