Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

AB FLEX I/O Remote I/O Adapter Module

来源: | 作者:FAN | 发布时间 :2025-04-23 | 592 次浏览: | Share:

AB FLEX I/O Remote I/O Adapter Module

Safety and Usage Precautions

Prohibited Scenarios: Do not use with Classic PLC-5/15 or PLC-5/25 processors.

Safety Guidelines: Solid-state devices have different characteristics than electromechanical devices and should be used in accordance 

with applicable safety guidelines; Rockwell Automation is not responsible for consequential damages.

Environmental Requirements: Suitable for use in pollution class 2, overvoltage category II industrial environments at altitudes up to 

2000 metres above sea level, Group 1, Class A industrial equipment, and in a suitable enclosure.

Static electricity protection: The equipment is sensitive to static electricity, anti-static measures are required during operation.

Other notes: There are strict requirements on the length of power supply wiring, grounding methods, preventing the entry of foreign objects, 

and avoiding electrically charged operation.


Approval for use in hazardous areas

Europe: The modules are approved for use in Zone 2 in Europe and are subject to specific requirements, such as UV protection and enclosure protection.

North America: Modules are approved for use in hazardous areas in North America, with product labelling ‘CL I, DIV 2, GP A, B, C, D’, 

and use is subject to temperature codes and combined equipment review.



Installation Steps

Pre-installation Preparation: Clearly identify components and understand standard addressing modes and substitution relationships.

Mounting to DIN rail: Hook adapter onto DIN rail and rotate down to ensure it locks into place, if not it can be done with a tool.

Replacement in an existing system: Remove the relevant parts in order, take care to align the slots when installing the new adapter, 

and reconnect the wiring when the installation is complete.

Wiring: Connect the remote I/O cable, power supply, pay attention to the location and order of wiring, if the last adapter needs to be terminated resistor.

Addressing mode setting: Select the addressing mode by setting S1 and S2 switches, different modes correspond to different switch settings, 

and need to re-power on after setting.


Practical Application Cases

Automobile production line: In the automobile production workshop, a large number of equipments need to be monitored and controlled in real time. 

For example, in the body welding process, many welding robots and sensors need to communicate with the control system. 

FLEX I/O Remote I/O Adapter Module can connect the digital input and output signals of the robot, such as controlling the start and stop of the welding gun, 

and monitoring the analogue signals of the welding current and voltage sensors. 

With its multiple addressing modes, it can be flexibly configured to address different devices and transmit data stably to the main control system via 57.6Kbps, 

115.2Kbps or 230.4Kbps communication rates, ensuring that the welding work is carried out accurately and improving production efficiency and product quality.

Chemical production process control: The chemical production environment is complex, with corrosive gases and potential explosion risks. 

For example, the 1794 - ASBK series E module (for hazardous gas environments) can be used for liquid material transport and reaction control. 

It connects flow sensors, pressure sensors to monitor the material flow, reactor pressure and other analogue signals, 

as well as digital signals to control the opening and closing of valves. By communicating with the control system, 

it regulates the production process according to the set parameters. Module grounding and protection design, 

with explosion-proof shell, can ensure stable operation in chemical hazardous environments 

and prevent safety accidents caused by electrostatic discharge and electrical failure.


Intelligent warehousing and logistics systems: In automated three-dimensional warehouses, shuttle cars, stacker cranes, 

and other equipment need to be controlled precisely, and the FLEX I/O remote I/O adapter module connects the equipment's motor drives, position sensors, 

etc. The module can, for example, be used to monitor the position of a stacker crane. 

For example, the digital signals from the position sensors of the stacker cranes are monitored to determine their position between shelves, 

and the module's communication function transmits the position information to the control system, 

which then controls the movement of the stacker cranes accordingly. 

Its flexible installation method and various wiring specifications facilitate installation and connection in the complex wiring environment of 

storage equipment to achieve efficient cargo storage and retrieval.


Parameter specifications

I/O Capacity: The I/O capacity of 1794-ASB/E and 1794-ASBK/E is 8 modules, while 1794-ASB2/D is 2 modules. This determines the number of FLEX I/O modules that can be connected to them. In industrial automation projects of different sizes, the appropriate model can be selected according to the actual equipment connection requirements. For example, for a small production line with relatively few devices, the 1794-ASB2/D may be able to meet the connection requirements, while a complex production line in a large factory involving the monitoring and control of many devices may require a module with a larger I/O capacity such as the 1794-ASB/E.

  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module