GE Multilin 889 Generator Protection System
DESCRIPTION
The Multilin™ 889 Generator Protection System, a member of the Multilin 8 Series protection relay platform, has been designed for the protection, control, and management of generators and associated unit transformers in critical utility and industrial applications.
The 889 goes beyond asset protection providing power system engineers with the data, measurement accuracy, and visibility needed for comprehensive generator management. These advanced asset monitoring capabilities provides engineers with the ability to make informed, proactive decisions that enable planned maintenance activities reducing costs associated with pre- and post-fault analysis, equipment damage, and unplanned or extended downtime.
With a focus on connectivity and security, the 889 supports the latest in communications technologies and protocols including IEC 61850 Edition 2, OPC-UA, and IEC 62439/PRP, and provides advanced, industry standard, cybersecurity tools, ensuring simplified and secure device integration into new or existing SCADA or DCS systems.
Key Benefits
• Enhanced generator protection algorithms provide sub-cycle differential protection, ensuring faster fault clearing times for reduced generator damage
• Dedicated generator monitoring and control functions providing mission critical operational data to enable a pro-active maintenance approach
• Additional overall generator-transformer differential (87O) providing additional back-up protection
• Advanced generator diagnosis, comprehensive asset monitoring and high-end fault and disturbance recording, simplifies pre- and post-fault analysis
• Advanced cyber security features including AAA, Radius, RBAC and Syslog enabling NERC/CIP requirements
• Low insertion force, draw-out design simplifying testing, commissioning, and maintenance for increased process uptime
• Optional Wi-Fi connectivity minimizes system configuration and facilitates remote relay programming and diagnostic retrieval
• Patented environmental monitoring, providing visibility to changes in environmental conditions that can affect relay life
Applications
• Comprehensive protection from small to large generators
• Industrial or utility power generation
• Co-generation and renewable generation applications
• Unit Transformer Protection applications
Innovative Technology & Design
• Proven algorithms delivering sub-cycle and reliable differential protection
• Continuous monitoring and event driven diagnostics for a wide range of generator applications
• Patented environmental monitoring & diagnostics
• Advanced, flexible and embedded communications: IEC® 61850 Ed2, OPC-UA, IEC 62439/PRP, Modbus® RTU & TCP/IP, DNP3.0, IEC 60870-5-104
• Single setup and configuration across the 8 Series platform
• Field swappable power supply
• Enhanced relay draw-out construction
• Elimination of electrolytic capacitors
Exceptional Quality & Reliability
• IPC A-610-E Class 3 manufacturing standards
• Highest reliability standards for electronics testing
• 100% Environmental Stress Screening and full functional testing
• Rated for IP54 (front) applications
• Standard Harsh Environment Conformal Coating
Generator Stator Differential
The 889 provides fault clearing operation at up to sub-cycle speed, by utilizing a high-speed dual slope differential protection for detecting and clearing of stator phase faults. Advanced CT saturation detection algorithms maintain immunity to saturation conditions that may be caused due to external disturbances. Through the use of a directional check, additional supervision is provided to ensure the fault is internal to the generator before triggering it to trip. This sub-cycle operation translates to less burning, and hence low carbon dissipation and thermal stress on insulation. This also enables root cause analysis during diagnosis/ maintenance of the winding (sever longer duration faults burns-out all the evidence and make root cause analysis extremely difficult or sometimes impossible).
Overall Generator & Transformer Differential Protection
The 889 provides overall generator and transformer differential protection (87O). It covers the protection zones from the generator neutral to the Generator Step-Up (GSU) Transformer’s High Voltage (HV) winding. For mid to large-size machines, the typical protection philosophy and architecture is to implement a dedicated transformer protection device along with a single function differential relay to provide the overall differential protection between the transformer and the generator. With support for 3 sets of phase CT inputs, the 889 can replace the single function device, providing the necessary overall differential protection with the added benefit of protection redundancy for both the Transformer and the Generator, when there is no tapping between the generator and GSU or unit transformer.