Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

GE Multilin MIF series digital feeder relay

F: | Au:FAN | DA:2025-09-22 | 934 Br: | 🔊 点击朗读正文 ❚❚ | Share:

GE Multilin MIF series digital feeder relay

Product basic positioning and core applications

1. Product type and positioning

The MIF series belongs to the M Family (M series) digital feeder relay, which is divided into two core models according to the protected object:

MIF-P type: three-phase+grounding protection relay, suitable for comprehensive protection of three-phase distribution circuits;

MIF-N type: single-phase or ground protection relay, focusing on single-phase circuit or ground fault special protection.

2. Core application scenarios

Main protection: Main circuit protection for various voltage levels of distribution networks, covering lines, distribution equipment, etc;

Backup/auxiliary protection: Backup protection for transformers, generators, and motors to compensate for blind spots in main protection;

Control and Monitoring: Cooperate with circuit breakers to achieve remote control, while providing electrical parameter measurement and equipment status monitoring.

Core functions and technical features

1. Protection function (core highlight)

The MIF series focuses on "overcurrent protection" and is equipped with various specialized protections to adapt to different fault scenarios

(1) Overcurrent protection (TOC/IOC)

Protection type applicable model key parameters and characteristics

Phase TOC MIF-P (three-phase), MIF-N (single-phase) - Setting range: 0.1-2.4 times rated current (I n)

-Curve selection: 4 standard curves (corresponding to ANSI/IEC)+1 user-defined curve, supporting time multiplier adjustment

-ANSI corresponds to IEC curves: Normal Inverse Time (ANSI) → IEC A, Extraordinary Inverse Time → IEC B, Extreme Inverse Time → IEC C, Timed Limit → Timed Limit

Ground TOC MIF-P (standard), MIF-N (optional) - Curve and parameter settings for in-phase overcurrent protection

-Grounding signal acquisition: By default, the residual current of three-phase CT is summed up (without the need for additional sensors); Sensitive scenes can be paired with zero sequence grounded CT (surrounding three-phase conductors) to improve detection accuracy

Instantaneous Overcurrent (IOC) Full Model - Independent Configuration: MIF-P includes 2 sets of three-phase IOC+2 sets of grounded IOC, MIF-N includes 2 sets of single-phase/grounded IOC

-Setting range: pickup (0.1-30 times I n), delay (0-100 seconds), supports individual enable/disable

(2) Other special protections

Thermal Image Protection: prevents equipment from being damaged due to overload and overheating, with a constant heating time

T1 (adjustable from 3-600 minutes), cooling time constant T2 (adjustable from 1-6 times T1), suitable for different device heat dissipation characteristics;

Cold Load Pickup (optional): Automatically adjust the overcurrent setting value when powering on again to avoid triggering the protection by overload current;

Breaker Failure Protection (optional): The basic function is to detect that the circuit breaker has not been opened; Complex solutions can be implemented through digital inputs and configurable output logic (logic gates, timers);

Breaker Health Monitoring (optional): Users set a cumulative current threshold, triggering an alarm when the threshold is exceeded, achieving "on-demand maintenance".

2. Control and operation functions

Circuit breaker control: supports circuit breaker opening/closing operations, triggered by programmed output terminals, and verified by digital input terminals to ensure successful operation;

Two Settings Groups: Two sets of protection parameters can be pre-set to adapt to different operating conditions (such as normal load/peak load);

On site upgrade: Designed with Flash Memory, it supports firmware upgrade through communication or software on-site, without the need to disassemble the device.

3. Monitoring and metering functions

Event recording: Store 32 event records, record key events such as faults and operations, for easy fault tracing;

Waveform recording: supports analog/digital waveform recording, captures instantaneous changes in electrical parameters during faults, and assists in fault analysis;

Dual end metering: CT transformation ratio can be set, and the primary and secondary current measurement values can be monitored simultaneously to meet the data requirements of operation and maintenance.

4. Hardware and interface characteristics

Power adaptation: Supports AC/DC universal power supply, covering 24-48V DC/AC, 110-250V DC, 110-230V AC (specific range see ordering parameters);

Communication interface: Front end RS232 port (local debugging), back-end RS485 port (remote communication), both support ModBus ®  RTU protocol, with a maximum speed of 19200 bps;

I/O configuration: comes standard with 2 digital inputs and 6 relay outputs (4 programmable), and can customize output logic (OR/NOT combination) through M+PC software;

Mechanical structure: Drawout case for easy maintenance; Compatible with M-series 19 inch half rack/full rack installation, compatible with system integration.

5. Software and user interaction

Configuration software: supports M+PC software (parameter settings, status monitoring), enerVista.com platform (remote management, see page 275 of the document for details);

Local operation: Front panel buttons for direct parameter adjustment and status viewing;

Indicator lights (LEDs): LED indicator lights can be configured to visually display the device's operating status and fault type.

Wiring and safety regulations

1. Typical wiring reference

Grounding detection wiring: Two options are available - ① Three phase CT residual current summation (no additional sensors required); ② Zero sequence grounding CT (sensitive detection scenario);

Current input: It is recommended to use a 14 AWG (2.5mm ²) wire, and the terminal should be a fork or ring terminal;

Safe grounding: It is necessary to connect to a safe ground. Terminals B12, A12, and B11 are only for connecting SELV (safety extra low voltage) components (such as PLC), and withstand voltage testing is prohibited.

2. Safety Tips

Overvoltage category: Class II, suitable disconnect devices (switches or circuit breakers) need to be installed near the relay;

Internal fuse: The power circuit is equipped with a 1A/250V fast fuse to protect the equipment in case of malfunction.


Ordering information (model coding rules)

The MIF series model code format is * * MIF * * * * E * 00 * 00 * * *, and the meanings of the characters in each position are as follows, which need to be combined according to actual needs:

Encoding Position Optional Character Meaning Explanation

1st to 3rd digit MIF product identification (digital feeder relay)

The 4th P/N P=three-phase+grounding relay; N=single-phase or grounded relay

5th A/I A=ANSI standard curve; I=IEC standard curve

6th position 0/1/5=MIF-N type; 1=MIF-P type (I n=1A, setting range 0.1-2.4A); 5=MIF-P type (I n=5A, setting range 0.5-12A)

7th position 1/5/N grounding CT rated current: 1=1A (0.1-2.4A); 5=5A(0.5-12A); N=sensitive grounding (1A, 0.005-0.12A)

8th position (empty)/1/2 empty=base model (no options); 1=Option 1 (configurable I/O, event logging, recording); 2=Option 2 (including option 1 function+cold load input, circuit breaker failure/health monitoring, configurable logic)

The power specifications for positions 9-10 are 24-48V DC/AC (19-58V DC); 110-250V DC(88-300V DC); 110-230V AC(88-264V AC)

The installation method for positions 11-12 is empty=independent relay; M+=Installed on M+system (requires additional order of M050 half 19 inch rack or M100 full 19 inch rack, provided free of charge according to the number of relays)

Example

MIF P A 1 1 2 110: Three phase+grounding relay (P), ANSI curve (A), phase CT I n=1A (1), grounding CT I n=1A (1), including option 2 function (2), 110-250V DC power supply (110).

  • Triconex 3723X Analog Input Module with HART
  • Sumitomo SM-Cyclo RNFMS01-20L-80 Motor Gear
  • Sumitomo AF503-3A7 Transistor Inverter
  • CASE Sumitomo KHR30842 KHR30840 Cab Harness
  • Sumitomo FCS-A25G-29 PB051710 Gear Kit
  • Sumitomo KHR1787 SMCU-5 Controller
  • Sumitomo AF503-2A2 Inverter 3.9kVA
  • AMT 9502 Touch Screen Panel
  • Sumitomo CHHJS-6135Y-R2-6 Gearbox Adapter
  • Sumitomo PA136445 RNYMS02-1320YC-40 Gearmotor
  • Sumitomo ANFX-P130F-1GL3-33 Gearbox
  • Sumitomo SH55U-2 Rubber Track
  • Sumitomo US60125-GA AC Servo Driver SS6000
  • Sumitomo CNFXS6075LB21 Cyclo Drive Reducer Motor
  • Sumitomo QT62-125F-BP-Z Hydraulic Gear Pump
  • Sumitomo CNFX-6090G-11/G Gearbox
  • Sumitomo X81D1-0102 SEM-I-1614 Control Module
  • Sumitomo Eaton C300-S Counterbalance Valve
  • Sumitomo GR-RF20 Z4-12193-5 Ozone Generator
  • Sumitomo T.SBXH1.5PL-25PD LN Modulator
  • Sumitomo 8700109 AS-3340 rev D CPU Module
  • Sumitomo SHI Cyclo Drive F3CS-A25G-89 Reducer
  • Sumitomo KNR0827 Wiring Harness SH120-3 SH120A3
  • Sumitomo ULC100011-01 LNR Actuator Driver
  • LUBE GMN-10-200-CB2-7L Lubricator Grease Pump
  • Sumitomo SH65UJ Rubber Track
  • Sumitomo KHR69310 Excavator Monitor
  • Sumitomo FDT-2FS Fiber Identifier Power Meter
  • Sumitomo CNVMS-4085G-43 Ink Fountain Motor
  • Sumitomo GV9924023-38 Circuit Board
  • Sumitomo 407915-5510 4BG1TRA ECU Controller
  • Sumitomo Cyclo F71m/4 Induction Motor 0.37kW
  • Sumitomo ANFJ-K30-SV-9 Hydraulic Control Valve
  • Hitachi Sumitomo 4625051 Pilot Valve Joystick
  • Sumitomo Demag W4RAP 6 W7-04-30 Valve
  • Sumitomo RV F2CF-A35-119 Gearbox
  • Sumitomo SH120 Slew Ring JCB JS130
  • Sumitomo Truninger QT-42-20HS-A Gear Pump
  • Sumitomo D2X-00577/02 SLV Control Board
  • Sumitomo Type-36 ARC Fibre Fusion Splicer
  • Sumitomo WRX33000R125-300 Shell Milling Cutter
  • Sumitomo Fine Cyclo F4CS-C35-59 Gearbox
  • Sumitomo Demag 4WREE 10 W75-23 Flow Valve
  • Sumitomo RDK-408A3 MRI Cold Head 5445412
  • Sumitomo AF-500 AF502-1A5 Cold Head
  • Sumitomo TYPE-35SE Fiber Optic Fusion Splicer
  • Sumitomo SH60 Rubber Track
  • Sumitomo SXPL JA765811BE Controller Interface Display
  • Sumitomo RF4100R Shell Mill 6 Flute 1.25 inch Arbor 4 inch OD
  • Sumitomo SHI SA765621AX SA765587BC Control Module
  • Sumitomo P-022CD-1A Cold Head Drive Unit
  • Sumitomo NL6448AC33-18 JA762898AD Operator Panel
  • Sumitomo JA762870GC Populated Circuit Board
  • Sumitomo Type-37 SM MM Fusion Splicer
  • Steel Track Chain for Sumitomo SH75 Excavator
  • Sumitomo CNV-6095-6 Cyclo Drive
  • Sumitomo Fine Cyclo F4CS-C35-59 PB048860 GEB
  • Sumitomo TC-FXPA FB-2E Motor RNYM2-1520A-EP-B-60 Gearbox
  • Sumitomo Heavy Industries RDK-4XX MRI Cold Head
  • Sumitomo SA765523AX PMDRV PCB Card 7MBP50RA060
  • Sumitomo Drive 307H-25 119H2505 Speed Reducer
  • Sumitomo Eaton H-130AA2FXJ Orbit Motor
  • Sumitomo JA775810A3 Nozzle Heater 19-58 130W
  • Sumitomo ZNFM05 Gearbox
  • Sumitomo F1C-A25-119 Gearbox
  • Sumitomo Fusion Splicer Type 39BT
  • Sumitomo MC78 UMC78S000-01 Motion Controller
  • Sumitomo Cyclo 2 Speed Motor Brake Gearbox
  • Sumitomo Drive PA213763 RNYMS02-1320YC-40
  • Sumitomo JA450704A2 Cylinder Head
  • Sumitomo T39 Fusion Splicer
  • Sumitomo AF-500 Cold Head
  • Sumitomo 71C Fusion Splicer
  • Sumitomo RDK-408S Cryocooler Cold Head
  • Sumitomo L3 Coldhead
  • Sumitomo F2CS-A25-119 Gearhead
  • Sumitomo US60125-GA AC Servo Driver SS6000
  • Sumitomo Type 39 Fusion Splicer
  • Sumitomo ANFJ-K30-SV-9 Planetary Gearbox
  • Sumitomo Heavy Industries JA761557BC RSC86-I Control Board
  • Sumitomo SA765604AX SA765603BC SXEX Servo Control Board
  • Sumitomo SumiDrill WDX2250D3S150 Drill
  • Sumitomo Type-66M12 Mass Fusion Splicer
  • Sumitomo Heavy Industries JA761557AC RSC86-I Control Board
  • Sumitomo JA761015CC RSC86 Circuit Board
  • Sumitomo T-72M12 Mass Fusion Splicer
  • Sumitomo TYPE-72C-KIT Core Aligning Fusion Splicer
  • Sumitomo CI-10/600-ADSD1-2 Power Supply
  • Sumitomo HF5202-3A7 Electronic Module
  • Sumitomo JA761015EC RSC86 Servo Control Board
  • Sumitomo TYPE-39 DCM Micro Core Fusion Splicer
  • Sumitomo JA761070HC AP-M Circuit Board
  • Sumitomo TYPE-400S T-400S Fusion Splicer Kit
  • Sumitomo TYPE-201E-VS Quantum Fusion Splicer
  • Sumitomo MC78IO Drive Power Module
  • Sumitomo 3-Phase Motor Gearbox 4kW 241RPM
  • CASE KRC10510 Hydraulic Swing Motor Sumitomo
  • Sumitomo HF4302-011 HF-430 Inverter Drive 11kW
  • Sumitomo SA765654BC SXIO-B Control Board
  • Sumitomo SDPH-018CHB PWM Amplifier Module
  • Sumitomo JA761070JC AP-M Circuit Board
  • Sumitomo HV960LC Local Control Board
  • Sumitomo T-71C+ Fusion Splicer Camera Y Focus Error
  • Sumitomo CH-210 Cold Head Cryo Cooler
  • Sumitomo Type-71C+ DCM Fusion Splicer
  • Sumitomo Type-65M12 Ribbon Fiber Fusion Splicer
  • Sumitomo T-502S Elite Fusion Splicer
  • Sumitomo T-72C+ Fusion Splicer
  • Sumitomo JA767632AC Circuit Board
  • Sumitomo Type-72C+ Core Alignment Fusion Splicer
  • Sumitomo CP5003 101AGG01 Sequencer I/F Board
  • Sumitomo T-37SE Fibre Fusion Splicer
  • Sumitomo Type-71C-KIT-PLUS Fusion Splicer
  • Sumitomo Type-72C HD Fusion Splicer
  • Sumitomo Type-72C+ Fusion Splicer FC-6+
  • Sumitomo Type-65M12 Ribbon Fusion Splicer
  • Sumitomo Type-72C+ Fusion Splicer
  • Sumitomo Type-39 DCM Fusion Splicer
  • Sumitomo Z1C Core Alignment Fusion Splicer
  • Sumitomo Type-71C DCM Fusion Splicer
  • Sumitomo T-72M12 Ribbon Fusion Splicer
  • ABB SACO 64D4 Digital Annunciator Unit 64-Channel Alarm System
  • EMERSON FloBoss S600+ P154 PRV Board 7381540 Prover Module
  • EMERSON FloBoss S600+ P155 PSU Board 7161550 Power Supply
  • EMERSON FloBoss S600+ P153 Front Panel 7181530 Display Keypad
  • EMERSON FloBoss S600+ P148 Dual Pulse Mezzanine 7181483 Module
  • EMERSON FloBoss S600+ P144 I/O Board 7281440 Analog Digital Module
  • EMERSON FloBoss S600+ P152 CPU Board 7381520 Main Processor