GE Multilin MIF series digital feeder relay

来源: | 作者:FAN | 发布时间 :2025-09-22 | 477 次浏览: | Share:

GE Multilin MIF series digital feeder relay

Product basic positioning and core applications

1. Product type and positioning

The MIF series belongs to the M Family (M series) digital feeder relay, which is divided into two core models according to the protected object:

MIF-P type: three-phase+grounding protection relay, suitable for comprehensive protection of three-phase distribution circuits;

MIF-N type: single-phase or ground protection relay, focusing on single-phase circuit or ground fault special protection.

2. Core application scenarios

Main protection: Main circuit protection for various voltage levels of distribution networks, covering lines, distribution equipment, etc;

Backup/auxiliary protection: Backup protection for transformers, generators, and motors to compensate for blind spots in main protection;

Control and Monitoring: Cooperate with circuit breakers to achieve remote control, while providing electrical parameter measurement and equipment status monitoring.

Core functions and technical features

1. Protection function (core highlight)

The MIF series focuses on "overcurrent protection" and is equipped with various specialized protections to adapt to different fault scenarios

(1) Overcurrent protection (TOC/IOC)

Protection type applicable model key parameters and characteristics

Phase TOC MIF-P (three-phase), MIF-N (single-phase) - Setting range: 0.1-2.4 times rated current (I n)

-Curve selection: 4 standard curves (corresponding to ANSI/IEC)+1 user-defined curve, supporting time multiplier adjustment

-ANSI corresponds to IEC curves: Normal Inverse Time (ANSI) → IEC A, Extraordinary Inverse Time → IEC B, Extreme Inverse Time → IEC C, Timed Limit → Timed Limit

Ground TOC MIF-P (standard), MIF-N (optional) - Curve and parameter settings for in-phase overcurrent protection

-Grounding signal acquisition: By default, the residual current of three-phase CT is summed up (without the need for additional sensors); Sensitive scenes can be paired with zero sequence grounded CT (surrounding three-phase conductors) to improve detection accuracy

Instantaneous Overcurrent (IOC) Full Model - Independent Configuration: MIF-P includes 2 sets of three-phase IOC+2 sets of grounded IOC, MIF-N includes 2 sets of single-phase/grounded IOC

-Setting range: pickup (0.1-30 times I n), delay (0-100 seconds), supports individual enable/disable

(2) Other special protections

Thermal Image Protection: prevents equipment from being damaged due to overload and overheating, with a constant heating time

T1 (adjustable from 3-600 minutes), cooling time constant T2 (adjustable from 1-6 times T1), suitable for different device heat dissipation characteristics;

Cold Load Pickup (optional): Automatically adjust the overcurrent setting value when powering on again to avoid triggering the protection by overload current;

Breaker Failure Protection (optional): The basic function is to detect that the circuit breaker has not been opened; Complex solutions can be implemented through digital inputs and configurable output logic (logic gates, timers);

Breaker Health Monitoring (optional): Users set a cumulative current threshold, triggering an alarm when the threshold is exceeded, achieving "on-demand maintenance".

2. Control and operation functions

Circuit breaker control: supports circuit breaker opening/closing operations, triggered by programmed output terminals, and verified by digital input terminals to ensure successful operation;

Two Settings Groups: Two sets of protection parameters can be pre-set to adapt to different operating conditions (such as normal load/peak load);

On site upgrade: Designed with Flash Memory, it supports firmware upgrade through communication or software on-site, without the need to disassemble the device.

3. Monitoring and metering functions

Event recording: Store 32 event records, record key events such as faults and operations, for easy fault tracing;

Waveform recording: supports analog/digital waveform recording, captures instantaneous changes in electrical parameters during faults, and assists in fault analysis;

Dual end metering: CT transformation ratio can be set, and the primary and secondary current measurement values can be monitored simultaneously to meet the data requirements of operation and maintenance.

4. Hardware and interface characteristics

Power adaptation: Supports AC/DC universal power supply, covering 24-48V DC/AC, 110-250V DC, 110-230V AC (specific range see ordering parameters);

Communication interface: Front end RS232 port (local debugging), back-end RS485 port (remote communication), both support ModBus ®  RTU protocol, with a maximum speed of 19200 bps;

I/O configuration: comes standard with 2 digital inputs and 6 relay outputs (4 programmable), and can customize output logic (OR/NOT combination) through M+PC software;

Mechanical structure: Drawout case for easy maintenance; Compatible with M-series 19 inch half rack/full rack installation, compatible with system integration.

5. Software and user interaction

Configuration software: supports M+PC software (parameter settings, status monitoring), enerVista.com platform (remote management, see page 275 of the document for details);

Local operation: Front panel buttons for direct parameter adjustment and status viewing;

Indicator lights (LEDs): LED indicator lights can be configured to visually display the device's operating status and fault type.

Wiring and safety regulations

1. Typical wiring reference

Grounding detection wiring: Two options are available - ① Three phase CT residual current summation (no additional sensors required); ② Zero sequence grounding CT (sensitive detection scenario);

Current input: It is recommended to use a 14 AWG (2.5mm ²) wire, and the terminal should be a fork or ring terminal;

Safe grounding: It is necessary to connect to a safe ground. Terminals B12, A12, and B11 are only for connecting SELV (safety extra low voltage) components (such as PLC), and withstand voltage testing is prohibited.

2. Safety Tips

Overvoltage category: Class II, suitable disconnect devices (switches or circuit breakers) need to be installed near the relay;

Internal fuse: The power circuit is equipped with a 1A/250V fast fuse to protect the equipment in case of malfunction.


Ordering information (model coding rules)

The MIF series model code format is * * MIF * * * * E * 00 * 00 * * *, and the meanings of the characters in each position are as follows, which need to be combined according to actual needs:

Encoding Position Optional Character Meaning Explanation

1st to 3rd digit MIF product identification (digital feeder relay)

The 4th P/N P=three-phase+grounding relay; N=single-phase or grounded relay

5th A/I A=ANSI standard curve; I=IEC standard curve

6th position 0/1/5=MIF-N type; 1=MIF-P type (I n=1A, setting range 0.1-2.4A); 5=MIF-P type (I n=5A, setting range 0.5-12A)

7th position 1/5/N grounding CT rated current: 1=1A (0.1-2.4A); 5=5A(0.5-12A); N=sensitive grounding (1A, 0.005-0.12A)

8th position (empty)/1/2 empty=base model (no options); 1=Option 1 (configurable I/O, event logging, recording); 2=Option 2 (including option 1 function+cold load input, circuit breaker failure/health monitoring, configurable logic)

The power specifications for positions 9-10 are 24-48V DC/AC (19-58V DC); 110-250V DC(88-300V DC); 110-230V AC(88-264V AC)

The installation method for positions 11-12 is empty=independent relay; M+=Installed on M+system (requires additional order of M050 half 19 inch rack or M100 full 19 inch rack, provided free of charge according to the number of relays)

Example

MIF P A 1 1 2 110: Three phase+grounding relay (P), ANSI curve (A), phase CT I n=1A (1), grounding CT I n=1A (1), including option 2 function (2), 110-250V DC power supply (110).

  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module