GE Multilin MIF series digital feeder relay

来源: | 作者:FAN | 发布时间 :2025-09-22 | 395 次浏览: | Share:

GE Multilin MIF series digital feeder relay

Product basic positioning and core applications

1. Product type and positioning

The MIF series belongs to the M Family (M series) digital feeder relay, which is divided into two core models according to the protected object:

MIF-P type: three-phase+grounding protection relay, suitable for comprehensive protection of three-phase distribution circuits;

MIF-N type: single-phase or ground protection relay, focusing on single-phase circuit or ground fault special protection.

2. Core application scenarios

Main protection: Main circuit protection for various voltage levels of distribution networks, covering lines, distribution equipment, etc;

Backup/auxiliary protection: Backup protection for transformers, generators, and motors to compensate for blind spots in main protection;

Control and Monitoring: Cooperate with circuit breakers to achieve remote control, while providing electrical parameter measurement and equipment status monitoring.

Core functions and technical features

1. Protection function (core highlight)

The MIF series focuses on "overcurrent protection" and is equipped with various specialized protections to adapt to different fault scenarios

(1) Overcurrent protection (TOC/IOC)

Protection type applicable model key parameters and characteristics

Phase TOC MIF-P (three-phase), MIF-N (single-phase) - Setting range: 0.1-2.4 times rated current (I n)

-Curve selection: 4 standard curves (corresponding to ANSI/IEC)+1 user-defined curve, supporting time multiplier adjustment

-ANSI corresponds to IEC curves: Normal Inverse Time (ANSI) → IEC A, Extraordinary Inverse Time → IEC B, Extreme Inverse Time → IEC C, Timed Limit → Timed Limit

Ground TOC MIF-P (standard), MIF-N (optional) - Curve and parameter settings for in-phase overcurrent protection

-Grounding signal acquisition: By default, the residual current of three-phase CT is summed up (without the need for additional sensors); Sensitive scenes can be paired with zero sequence grounded CT (surrounding three-phase conductors) to improve detection accuracy

Instantaneous Overcurrent (IOC) Full Model - Independent Configuration: MIF-P includes 2 sets of three-phase IOC+2 sets of grounded IOC, MIF-N includes 2 sets of single-phase/grounded IOC

-Setting range: pickup (0.1-30 times I n), delay (0-100 seconds), supports individual enable/disable

(2) Other special protections

Thermal Image Protection: prevents equipment from being damaged due to overload and overheating, with a constant heating time

T1 (adjustable from 3-600 minutes), cooling time constant T2 (adjustable from 1-6 times T1), suitable for different device heat dissipation characteristics;

Cold Load Pickup (optional): Automatically adjust the overcurrent setting value when powering on again to avoid triggering the protection by overload current;

Breaker Failure Protection (optional): The basic function is to detect that the circuit breaker has not been opened; Complex solutions can be implemented through digital inputs and configurable output logic (logic gates, timers);

Breaker Health Monitoring (optional): Users set a cumulative current threshold, triggering an alarm when the threshold is exceeded, achieving "on-demand maintenance".

2. Control and operation functions

Circuit breaker control: supports circuit breaker opening/closing operations, triggered by programmed output terminals, and verified by digital input terminals to ensure successful operation;

Two Settings Groups: Two sets of protection parameters can be pre-set to adapt to different operating conditions (such as normal load/peak load);

On site upgrade: Designed with Flash Memory, it supports firmware upgrade through communication or software on-site, without the need to disassemble the device.

3. Monitoring and metering functions

Event recording: Store 32 event records, record key events such as faults and operations, for easy fault tracing;

Waveform recording: supports analog/digital waveform recording, captures instantaneous changes in electrical parameters during faults, and assists in fault analysis;

Dual end metering: CT transformation ratio can be set, and the primary and secondary current measurement values can be monitored simultaneously to meet the data requirements of operation and maintenance.

4. Hardware and interface characteristics

Power adaptation: Supports AC/DC universal power supply, covering 24-48V DC/AC, 110-250V DC, 110-230V AC (specific range see ordering parameters);

Communication interface: Front end RS232 port (local debugging), back-end RS485 port (remote communication), both support ModBus ®  RTU protocol, with a maximum speed of 19200 bps;

I/O configuration: comes standard with 2 digital inputs and 6 relay outputs (4 programmable), and can customize output logic (OR/NOT combination) through M+PC software;

Mechanical structure: Drawout case for easy maintenance; Compatible with M-series 19 inch half rack/full rack installation, compatible with system integration.

5. Software and user interaction

Configuration software: supports M+PC software (parameter settings, status monitoring), enerVista.com platform (remote management, see page 275 of the document for details);

Local operation: Front panel buttons for direct parameter adjustment and status viewing;

Indicator lights (LEDs): LED indicator lights can be configured to visually display the device's operating status and fault type.

Wiring and safety regulations

1. Typical wiring reference

Grounding detection wiring: Two options are available - ① Three phase CT residual current summation (no additional sensors required); ② Zero sequence grounding CT (sensitive detection scenario);

Current input: It is recommended to use a 14 AWG (2.5mm ²) wire, and the terminal should be a fork or ring terminal;

Safe grounding: It is necessary to connect to a safe ground. Terminals B12, A12, and B11 are only for connecting SELV (safety extra low voltage) components (such as PLC), and withstand voltage testing is prohibited.

2. Safety Tips

Overvoltage category: Class II, suitable disconnect devices (switches or circuit breakers) need to be installed near the relay;

Internal fuse: The power circuit is equipped with a 1A/250V fast fuse to protect the equipment in case of malfunction.


Ordering information (model coding rules)

The MIF series model code format is * * MIF * * * * E * 00 * 00 * * *, and the meanings of the characters in each position are as follows, which need to be combined according to actual needs:

Encoding Position Optional Character Meaning Explanation

1st to 3rd digit MIF product identification (digital feeder relay)

The 4th P/N P=three-phase+grounding relay; N=single-phase or grounded relay

5th A/I A=ANSI standard curve; I=IEC standard curve

6th position 0/1/5=MIF-N type; 1=MIF-P type (I n=1A, setting range 0.1-2.4A); 5=MIF-P type (I n=5A, setting range 0.5-12A)

7th position 1/5/N grounding CT rated current: 1=1A (0.1-2.4A); 5=5A(0.5-12A); N=sensitive grounding (1A, 0.005-0.12A)

8th position (empty)/1/2 empty=base model (no options); 1=Option 1 (configurable I/O, event logging, recording); 2=Option 2 (including option 1 function+cold load input, circuit breaker failure/health monitoring, configurable logic)

The power specifications for positions 9-10 are 24-48V DC/AC (19-58V DC); 110-250V DC(88-300V DC); 110-230V AC(88-264V AC)

The installation method for positions 11-12 is empty=independent relay; M+=Installed on M+system (requires additional order of M050 half 19 inch rack or M100 full 19 inch rack, provided free of charge according to the number of relays)

Example

MIF P A 1 1 2 110: Three phase+grounding relay (P), ANSI curve (A), phase CT I n=1A (1), grounding CT I n=1A (1), including option 2 function (2), 110-250V DC power supply (110).

  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1C31129G03 Control Module
  • WESTINGHOUSE 1C31122G01 Process Controller | Ovation DCS Control Module
  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1B30023H02 Control Module
  • WESTINGHOUSE 1B30035H01 Turbine Control System Module
  • WIDAP UFW30.156 6K8J175W0823 Power Resistor Technical Profile
  • WINGREEN IPB PCB V2.0_A01 03ZSTL6-00-201-RS Industrial Power Board
  • WINGREEN CANopen_ADAPTER V5.0_A01 03ZSTI-00-501-RS Module
  • WINGREEN PUIM V2.0 034STM4-00-200-RS Power Interface Module
  • WINGREEN DUDT_DETECTION_V2.0_A01 03ZSTJ0-00-201-RS Detection Control Board
  • WINGREEN LAIB V3.0_A00 034STN1-00-300-RS Embedded Industrial Motherboard
  • WINGREEN FAN_DETECTION V1.0_A05 03ZSTJ3-00-105Fan Monitoring Module
  • WINGREEN LAIB V3.0_A00 034STN1-01-300-RS Interface Board
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-00-501 Industrial Control Keyboard Module
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-01-501 Industrial Motherboard | Embedded Control Board
  • WINGREEN FPB_V3.0_A01 03ZSTJ1-00-301-RS Fieldbus Processor
  • WINGREEN DSPB_V4.0_A02 03ZSTI7-00-402-RS Digital Processing Board
  • WOHNER 31110 Cylindrical Fuse Holder
  • WOODHEAD APPLICOM PCI4000 PCI Communication Card Industrial DeviceNet CAN Bus Interface
  • Woodward 8440-1706 Industrial Control System Module
  • Woodward 8440-2052 H Synchronizer Load Share Module
  • Baldor KPD-TS12C-30E 12.1" Color TFT Touch Screen Ethernet HMI
  • Baldor KPD-TS10C-30E 10" Color TFT Touch Screen Operator Interface with Serial and Ethernet Interfaces
  • Baldor KPD-TS05C-30E 5.6" Color TFT Touch Screen with Serial and Ethernet Interface
  • Baldor KPD-TS05C-30 5.6 Inch Color TFT Touch Screen Serial Interface
  • Baldor KPD-TS05M-10 5.6" Monochrome Touch Screen Serial Interface HMI
  • Baldor KPD-TS03M-10 Monochrome Touch Screen Operator Interface
  • Baldor KPD-KG420-30 4x20 Graphic Display with 12 Function Keys - Serial Interface
  • Baldor KPD-KG420-20 4x20 Character Graphic Display Serial Interface
  • WOODWARD EASYGEN-3200-5 8440-1992 A Genset Controller
  • WOODWARD PEAK200-HVAC 8200-1501 C Version | Industrial Building Automation Controller
  • Woodward 8440-2052 easyGEN-3200 Genset Control Power Management
  • Woodward 8237-1246 + 5437-1119 Control System Module
  • WOODWARD SPM-D11 8440-1703 Overspeed Protection System Module
  • WOODWARD 8237-1369 Governor Control Module
  • Woodward 8237-1600 Digital Control Module
  • WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-0000 3522-1004 Industrial Control Module
  • WOODWARD 8200-1302 Genset Controller
  • Woodward 8901-457 Speed Control Module
  • WOODWARD 5501-465 Control Module
  • Woodward 5448-890 SPM-D10 Digital Control Module
  • WOODWARD 5437-1067A Turbine Governor Actuator
  • Woodward 8440-1666 B Digital Control Module
  • WOODWARD 8440-1706 A SPM-D11 Synchronous Phase Modulator Module
  • WOODWARD 5466-425 Programmable Automation Controller (PAC)
  • WOODWARD 5466-318- Industrial Gas Turbine Control Module
  • WOODWARD 5453-277 Digital Control Module
  • WOODWARD 5453-203 Digital Governor Control Module
  • WOODWARD 9907-1106 Pressure Converter
  • WOODWARD 5233-2089 Professional Industrial Control System Module
  • WOODWARD 9907-147 Power outage tripping overspeed protection system
  • WOODWARD 8237-1600 Digital Speed Control System
  • WOODWARD 8402-319 8402-119 microprocessor speed controller
  • Woodward 8237-1006 Digital Governor
  • WOODWARD 5501-471 Communication Module
  • WOODWARD 5466-258 Input/Output Module
  • WOODWARD 5501-467 Multi Protocol Communication Gateway and I/O Expansion Module
  • WOODWARD 5501-470 Digital microprocessor controller module
  • WOODWARD 9907-1200 Digital Governor
  • WOODWARD 8444-1067 High Performance Digital Microprocessor Controller Module
  • WOODWARD 8446-1019 Integrated Gas Engine Electronic Control System
  • WOODWARD 9907-162 Digital Engine Governor
  • WOODWARD 5466-316 Simulation Combination Module
  • WOODWARD 5464-414 Digital Speaker Sensor Module
  • XANTREX XFR40-70 DC power supply
  • XP POWER F8B6A4A6A6 power module
  • XP POWER F8B6D4A3G3 power supply
  • XYCOM XVME-674 VMEbus Single Slot CPU/Processor Module
  • XYCOM XVME-957 Circuit Board
  • XYCOM XVME-976 PC board computer
  • XYCOM XVME-530 8-Channel Isolated Analog Output Module
  • XYCOM Proto XVME-085 Bus Module
  • YAMAHA RCX40 4-AXIS ROBOT CONTROLLER
  • YAMATAKE EST0240Z05WBX00 touch screen display
  • YAMATAKE HD-CAOBS00 flowmeter
  • HIMA X-COM 01 Communication Module
  • HIMA HIMax X-AO 16 01 Analog Output Module
  • HIMA X-AI3251 Analog Input Module
  • HIMA X-DO3251 Digital Output Module
  • HIMA X-DI3202 Digital Input Module
  • HIMA X-DI6451 Digital Input Module
  • YASKAWA USAHEM-02-TE53 AC servo motor
  • Yaskawa JZNC-XPP02B Teaching Programmer
  • YASKAWA CACR-SR07BE12M servo drive
  • YASKAWA JAMSC-B2732V Advanced Drive Controller
  • YASKAWA JGSM-06 Controller
  • YASKAWA PCCF-H64MS 64MB Industrial Memory Module
  • YASKAWA CACR-02-TE1K servo driver
  • YASKAWA JAPMC-IQ2303 Controller Module
  • YASKAWA DDSCR-R84H Controller
  • YASKAWA JANCD-XTU01B circuit board
  • YASKAWA JANCD-XIO01 High Performance PC Input/Output (I/O) Board
  • YASKAWA JACP-317800 servo drive
  • XYCOM 120974 - Circuit Board
  • XYCOM 99298-200 - PC Control Card 99207A-001
  • XYCOM 99298-266 - CPU Board
  • XYCOM 99311-001 - Screen Display Ribbon Cable
  • XYCOM 99384-002 - PCB Module 99383A-001
  • XYCOM A05520I01 - Control Module PW22471 MPL400
  • XYCOM A33369 - Dual PMC Carrier Module
  • XYCOM AC2064A1 - VMEbus PCB Board Analog Output
  • XYCOM AC2065A1 - VMEbus PCB Board Analog Output
  • XYCOM CDA XVME - DSP SCSI I/O Module Serial RS232
  • XYCOM 143913-001 - TSKAM Board Rev A
  • XYCOM 1300-000100000 - Operator Interface Node Module
  • XYCOM 140050(R) - Documentation Support Library
  • XYCOM 1811-A00000000 - SXT1811T Monitor 100-120V
  • XYCOM 3112T-1200-256-2K - Operator Interface
  • XYCOM 3115 T - Industrial Computer
  • XYCOM 3406T - Flat Panel Industrial PC
  • XYCOM 3512-03F114003 - Automation Operator Interface
  • XYCOM 3515-A2P214003 - Operators Interface 6.3A
  • XYCOM 3535 - Operation Panel 3535-E3T434003
  • XYCOM 3612 T - LCD Flat Panel Display
  • XYCOM 3715 - Industrial Touchpanel Touchscreen PC
  • XYCOM 4115 T - Light-Duty Flat Panel 2000-512-2K
  • XYCOM 50151 - Automation Display
  • XYCOM 5017-T - Flat Panel Industrial Touch Monitor
  • XYCOM 3308T - 8" Flat Panel Color Touchscreen PC
  • XYCOM 9000-FFP-HU - Industrial Module
  • XYCOM 9440 - Automation HMI 9440-026714001
  • XYCOM 3406 KPT - Automation Control Panel
  • XYCOM 3000-CBL-25VP - Video Cable 25' 7.5M
  • XYCOM CA3-MBPALL-41 - Modbus Plus Module for GP2000
  • XYCOM QPI-MBP-XA1 - Modbus Plus Communication Module
  • XYCOM 3512 T - Automation Model HMI PM-101722C
  • XYCOM PM-102159 - Xycom Automation Monitor