4.1 Filter selection
Single phase filter:
FI0015A00 (6A)/FI0015A02 (12A): Suitable for 115V/230V systems.
FI0029A00 (22A): 230V system, supports base installation, significantly saves panel space.
Three phase filter:
FI0018A00 (7.7A)/FI0018A03 (17.5A)/FI0018A01 (32.9A): Covering 230V-460V three-phase systems, supporting up to 27.5A applications.
4.2 Application Suggestions
For Series II and MicroFlex drivers, the document provides detailed selection guidelines to ensure effective suppression of conducted interference and stable operation of the equipment at different current levels.