Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Rexroth Bosch Group VT2000 Proportional Amplifier

来源: | 作者:FAN | 发布时间 :2026-04-17 | 11 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

VT2000 Proportional Amplifier Complete Guide: From Functional Principles to On site Troubleshooting

In industrial hydraulic systems, the control accuracy of proportional pressure valves directly depends on the performance of their electronic amplifiers. Bosch Rexroth's VT2000 series amplifiers are designed specifically for controlling direct acting and pilot operated proportional pressure control valves (without electrical position feedback). With the continuous operation of old equipment, many factories are still using VT2000 5X series or earlier 4X series amplifiers. When the amplifier malfunctions or needs to be replaced, engineers often face difficulties such as spare parts shutdown and missing documents. This article is based on the technical manual of VT2000, comprehensively analyzing its functional block diagram, terminal definitions, technical parameters, jumper settings, and on-site troubleshooting steps, helping hydraulic maintenance and system integration personnel quickly grasp the key points of using and replacing the amplifier.


Product positioning and core features of VT2000

VT2000 is a single channel proportional amplifier that adopts the European standard Euro card (100 × 160mm) size and is connected to the system through a 32 pin DIN 41612 male connector. The main design objective is to provide an adjustable current drive signal with ramp function for proportional pressure control valves. This amplifier is suitable for proportional pressure valves without electrical position feedback (i.e. open-loop control), which can change the spool position or pilot pressure by adjusting the electromagnetic current.

The core features include:

Differential input: can accept 0~+10V signals from PLC or other controllers, isolated from internal reference potential.

Additional command value input: 0~+9V (based on measuring zero position MO as a reference).

Slope generator: The time for ascending and descending slopes can be adjusted separately, and rapid slope can be forced through external contacts.

Clock type current output stage: outputs PWM modulated current with adjustable flutter frequency (100Hz or 200Hz) to reduce valve core friction.

Protection functions: reverse polarity protection of power supply, short circuit protection of electromagnetic cable, over temperature shutdown (no separate alarm signal).

Measurement socket: The front panel provides "w" (instruction value) and "I" (actual current value) test points for easy debugging.

This amplifier needs to be used in conjunction with an external power supply and card slot. Rexroth recommends using the VT3002-2X/32 single card slot (excluding power supply) and the VT-NE30-1X compact power supply (115/230VAC to 24VDC, 70VA).


Order code and version compatibility

The ordering code for VT2000 follows Rexroth's coding system. Although the complete code table is not listed in the document, important information is pointed out that the 5X series amplifier can be interchangeable with the 4X series under factory settings, provided that the ramp time is set to 5 seconds and the clock frequency is set to 200Hz. If you want to replace the 4X with 5X, you need to order an additional blind plate with a width of 4TE (due to differences in front panel width). Users should pay attention to checking the settings of the original system to ensure that the new amplifier jumper configuration is consistent with the old machine.


Detailed explanation of functional block diagram and signal flow

In order to effectively troubleshoot, it is necessary to understand the signal processing link inside VT2000. Below, we will explain one by one according to the signal flow direction.

3.1 Instruction value input level

The amplifier provides two input channels for instruction values:

Command value input 1: Voltage range 0~+9V, reference potential is MO (measure zero position). This input can be obtained by dividing it with an external potentiometer using an internal+9V regulated power supply. If the user uses an external potentiometer, the "Gw" potentiometer on the front panel of the amplifier must be adjusted to the maximum or to the position corresponding to the required maximum pressure.

Instruction value input 2 (differential input): voltage range 0~+10V, input resistance 100k Ω. Differential input is suitable for external electronic devices (such as PLC) and amplifiers that are not grounded together. When using differential input, two signal lines (28c and 30ac) must be connected or disconnected simultaneously.

The two command values are summed internally ([2]) and then sent to the command value attenuator (potentiometer "Gw" [3]) to limit the maximum output current (i.e. maximum pressure). The attenuated signal enters the ramp generator [4].

3.2 Slope Generator

The ramp generator converts step command values into ramp signals. The ramp time (from 0% to 100% command value) can be adjusted by two potentiometers to adjust the rise time and fall time respectively. The slope time range depends on the setting of jumper S1:

S1 jumper at "1s" position: ramp time 30ms~1s

S1 jumper at "5s" position: ramp time 30ms~5s

  • ABB UFC921A101 Main Control Board
  • ABB UFC921A Main Control Unit
  • ABB UFC911B108 Drive Main Control Unit
  • ABB UFC911B106 Drive Main Control Unit
  • ABB UFC911B101 Drive Main Control Unit
  • ABB UFC765AE102 Drive Control Interface Board
  • ABB UFC762AE101 I/O and Communication Extension Board
  • ABB UFC760BE41 I/O and Communication Extension Board
  • ABB UFC760BE145 I/O and Communication Extension Module
  • ABB UFC721BE101 Fieldbus Communication Adapter Module
  • ABB UFC721AE101 3BHB002916R0101 Network Interface
  • ABB UFC718AE101 HIEE300936R0101 Communication Module
  • ABB UDC920BE01 3BHE034863R0001 Communication Module
  • GE IS420UCSCH1A-F-VO.1-A Controller Module
  • GE UCSC H1 IS420UCSCH1A Controller Station Card
  • ABB UCD240A101 3BHE022287R0101 Process Controller
  • ABB UCD224A103 Process I/O Module
  • ABB UCD224A102 Analog Input Module
  • WOODWARD 9907-838 Load Sharing Module
  • B&R X20CP1485-1 Industrial PC CPU Module
  • ELAU MC-4/11/22/400 4-Axis Servo Drive
  • ELAU C600/10/1/1/1/00 Configurable Safety Relay
  • BENTLY 60R/SIM01 Proximitor Power Supply
  • BENTLY 60R/PPM01 Protection Processing Module
  • BENTLY 60R/PNL01 Operator Control Panel
  • BENTLY 60R/PIM01 Panel Interface Module
  • BENTLY 60R/INP07 Isolated DC Input Module
  • BENTLY 60R/INP01 4-Channel Analog Input Module
  • BENTLY 60R/CMM01 Communication Multiplexer Module
  • BENTLY 60R/CHA02 System Chassis Rack Enclosure
  • BENTLY 60R/CGW01 Condition Monitoring Gateway
  • Pacific Scientific P70360-SDN Servo Motor
  • HONEYWELL 05701-A-0284 Signal Conditioner
  • YOKOGAWA NFCP501-W05 Pressure Transmitter
  • ABB CI541V1 3BSE0146666R1 Control Interface
  • ABB DSTC176 57310001-KT Terminal Base Unit
  • ABB DSDP170K02 3BSE019925R1 Analog Input Module
  • ABB DSBC173 57310001-KH Terminal Base Unit
  • ABB DSAI130K01 5730-030-UC Thermocouple Input
  • ABB DSRF182 57310255-AL Relay Output Module
  • ABB SC520 3BSE003816R1 Compact PLC
  • ABB DSDP140A 57160001-ACT Analog Input Module
  • ABB DSAI130 57120001-P Analog Input Module
  • ABB SCYC55830 3AFE58063282 MCCB
  • Fireye 95DSS3-1CEX UV Flame Scanner
  • ABB DSDP170 57160001-ADF Analog Input Module
  • ABB CI532 3BSC140120R1 Communication Interface
  • ABB DSAO120A 3BSE018293R1 Analog Output Module
  • ABB CI869K01 3BSE049110R1 Ethernet Interface
  • ABB CI522A 3BSE018460R1 PROFIBUS DP Master
  • GUTOR OP6257 Rectifier Control Unit
  • Meggitt C327845-11 Gas Shutoff Valve
  • ABB SACO64D4 4-Pole Digital Annunciator Unit
  • ABB CI522AK04 3BSE018451R1 PROFIBUS DP Module
  • ABB DSAI130DK01 3BSE020828R1 Temperature Input Module
  • ABB CI546 3BSE012610R1 PROFIBUS DP Master Module
  • ABB SC510 3BSE003832R1 Compact PLC Controller
  • ABB CI540 3BSE001077R1 PROFIBUS DP Slave Module
  • ABB CI532V03 3BSE003828R1 AF 100 PROFIBUS DP Master
  • ABB DSBC172 57310256-EL Digital Input Terminal Base
  • Rexroth VT2000-5X Frequency Converter AC Drive
  • GE MAVS01L1AB0751D-140393N Soft Starter
  • ABB REF615 HBFDACADNAA1BCN1XE Relay
  • ABB SACO16D1 1-Pole Digital Annunciator Unit
  • ABB UNITROL 1000 3BHE014557R0003 Static Excitation System
  • Woodward 8273-1011 Electro-Hydraulic Actuator
  • Eaton MC2-442-57CQB-1-2A Molded Case Circuit Breaker
  • Siemens 3AY1715-6L VS30029P VS30041 Auxiliary Contact Block
  • ABB PCD235B101 3BHE032025R0101 Digital I/O Control Module
  • Socapel PAM-R1R-H8F-AP-P V10800 Programmable Axis Manager
  • Rexroth VT-HNC100-1-23N-08-P-0 Digital Hydraulic Amplifier
  • Woodward 5448-890 SPM-D10 Digital Synchronizer
  • TDK-Lambda HWS1500-24 Industrial Power Supply
  • Land M2300/1100C-V Infrared Pyrometer
  • Lantronix 080-332-000-R Industrial Device Server
  • LED E14 3W Miniature LED Lamp
  • LEM LC100S/SP7 Hall Effect Current Sensor
  • Lenel LNL-1320 Dual Reader Interface Module
  • Lenze L5311 Industrial Control Module
  • Lenze EPZ-10203 Safety Controller
  • Lenze EPL10200 Industrial Drive Module
  • Lenze EPL-10200-XX Drive Controller
  • Lam Research 810-801237-021 Industrial Part
  • Lam Research 810-073479-215 Precision Part
  • Lam Research 853-001983-110 Assembly Data
  • Lam Research 810-017034-005 Semiconductor Part
  • Lambda LZS-A1500-3 AC-DC Power Module
  • Lambda LZS-1500-3 Industrial Power Supply
  • LAM 810-072907-005 Chamber Interface Control Module
  • LAM 810-068158-014 Semiconductor Process Control Module
  • LAM 810-800081-018 Vacuum System Interface Module
  • LAM 810-068158-013 Semiconductor Control Module
  • Leybold CM330 Vacuum Gauge Controller
  • Leybold 850-400-G1 Vacuum Pump Module
  • LIFTMASTER 71-1550B18LGH Electric Actuator
  • LKB Bromma 2211 Pressure Sensor
  • LLASERGAS AO2000 LS25 12944-E Gas Analyzer Module
  • Load Controls PH-3A Three-Phase Power Sensor
  • Ludlum 2401-P Pancake GM Survey Meter
  • LUST VF1410LHFS41 AC Servo Drive
  • LUTZE UBE-FL/34M Terminal Block Contact
  • Marposs E78 Dynamic Balancing Controller
  • LENZE E84AVSCE1534VX0 Servo Drive Controller
  • LENZE EVF8212-E Frequency Inverter Drive
  • LENZE EA-4/10 Drive Expansion Module
  • LENZE BG10 Brake Module
  • LEUZE DDLS 200/200.1-50-M12 Data Link Data
  • LEUZE DDLS 200/200.2-50-M12 Optical Data
  • LEYBOLD TURBOVAC 361 Turbomolecular Pump
  • LEYBOLD TR211 Vacuum Controller Data
  • LEYBOLD SV40BI Rotary Vane Pump Specifications
  • LEYBOLD PR25 Vacuum Pressure Sensor Data
  • MARPOSS E9066 Precision Measurement Control Unit
  • MATROX Y7116-04 REV A Industrial Vision Processing Board
  • MATROX Y7116-01 REV A Industrial Video Processing Board
  • MCS SA1000 Industrial Signal Amplifier Module
  • MECS CS-1000 Control System Hardware Data
  • MECS UTX1010 Industrial Control Module
  • MECS UTX-1000A Industrial Module
  • MECS UTV-F2500HA High-Power Thyristor Data
  • MECS EXT-2 Advanced Expansion Interface
  • MECS EXT-1 Interface Extension Module
  • MECS CPU-1000 Industrial PLC Controller
  • MEN A201SR04 Embedded Computer
  • MERAK 681H10078 681K10078 681K10079 Control Modules
  • Mercury Step C-663 Stepper Motor Controller
  • MERLIN GERIN MX+0F 26948 Shunt Trip Release
  • MERLIN GERIN 32570 Miniature Circuit Breaker