Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

CyberPower UT650EG / UT850EG User’s Manual

来源: | 作者:FAN | 发布时间 :2025-09-25 | 454 次浏览: | Share:

CyberPower UT650EG / UT850EG User’s Manual

Core Security Directive (Must See)

To avoid fire, electric shock, or equipment damage, the following requirements must be strictly followed:

Installation environment: It can only be used in indoor temperature and humidity controlled environments (see technical parameters for specific range). It is forbidden to expose it to direct sunlight, heat sources (such as heaters and furnaces), do not cover the heat dissipation holes, and stay away from conductive pollutants.

Load limit: It is prohibited to connect non computer devices such as medical/life support equipment, microwave ovens, vacuum cleaners, etc; High power equipment such as laser printers, copiers, and shredders cannot be connected to battery powered sockets (which can easily overload and damage UPS).

Usage taboos: Do not allow liquids or foreign objects to enter the equipment, and do not place liquid containers around UPS; Power off before cleaning, and prohibit liquid or spray cleaners; Battery maintenance should be carried out by professionals and unauthorized personnel are prohibited from accessing it.

Emergency response: In case of emergency, press the "OFF" button and unplug the power cord to cut off the UPS power supply; If overload is detected, the device will sound a long beep alarm, power off and remove at least one load before restarting.

Equipment installation process

1. Open box inspection

The packaging box should contain:

Core components: UPS host (1 unit, UT650EG or UT850EG)

Accessories: User Manual (1 book), USB Data Cable (1 piece, only equipped with UT850EG)

2. Hardware installation steps

Battery charging: The device can be used directly after receiving it, but it is recommended to charge it for at least 8 hours (to offset the power loss during transportation and storage). Simply plug the UPS into an AC outlet (it can be charged in both on/off states).

Load connection: In the power-off state, connect the computer, monitor, and external data storage device to the "Battery Backup&Surge Protected Outlets" and disable high-power devices.

Power access: Insert the UPS plug into a grounded 2-hole 3-wire socket (wall plugs need to be protected by fuses or circuit breakers). Do not share the same circuit with high-power devices such as air conditioners and refrigerators, and try to avoid using extension cords.

Startup: Press the power switch, the power indicator light will turn on and the device will beep once, indicating successful startup.

Overload handling: If overload is detected, the device will sound a long alarm, and at least one load needs to be removed from the power supply. Wait for 10 seconds and confirm that the circuit breaker/fuse is normal before restarting.

Long term maintenance: To maintain the optimal condition of the battery, it is necessary to always connect the UPS to an AC socket; When storing for a long time, it is necessary to fully charge the battery and cover it for storage. Charge it every 3 months to extend the battery life.

Basic Operation Guide

1. Core buttons and interface functions

Function Description of Operating Components

Press and hold the power switch for 2 seconds to turn on/off the device; Quickly press twice to turn on/off the sound alarm (default on, 2 short beeps when turning off the alarm, 1 short beep when turning on the alarm)

The LED indicator light displays the UPS status (such as normal mains power, battery charging, fault, etc., see the "LED Status Definition Table" for details)

USB interface (UT850EG only) connects to the computer's USB port through PowerPanel ®  Personal software for UPS status communication and monitoring

The battery powered socket provides battery backup and surge protection, providing continuous power supply to the load during power outages

The replaceable fuse provides overload protection. If it melts due to overload, it needs to be replaced according to the specifications

Communication protection ports (RJ11/RJ45) protect modems, fax machines, telephone lines, and network/Ethernet connections from surge damage

2. Definition of LED indicator status

Different colors and flashing modes correspond to different device states, and the key explanation is as follows:

LED color, light status, sound alarm, UPS status, specific description

Green constant light - Energy saving mode (ECO): The mains power is normal, and the UPS is running in energy-saving mode

Green slow flashing - Battery charging is normal, UPS is charging the battery

The yellow light stays on and beeps twice every 30 seconds. The battery mode is interrupted, and the UPS switches to battery power supply

Yellow flashing, fast buzzing, low battery level, battery is about to run out, data needs to be saved and power off as soon as possible

Red constantly on+flashing once every 5 seconds with a continuous beep. Battery output short circuit fault. Power off and remove at least one load before restarting

Red constantly on+flashing twice every 5 seconds, continuous long beep. Overload fault. The load exceeds the rated capacity of the UPS and needs to be powered off to remove some of the load

  • Honeywell 51401497-100 FW25-92 LCN Interface Board
  • Honeywell 05701-A-0405 Digital Output Module
  • HONEYWELL XS824-25 Industrial Sensor Module
  • Honeywell 51120841-101 51120841-201 Power Filter Module
  • Honeywell CC-PUIO01 Module
  • HONEYWELL 0571-A-0328 Industrial Control Module
  • Honeywell 05701-A-0325 Series 57 Control Module
  • Honeywell 05701-A-0282 I/O Module
  • HONEYWELL TC-CCN014 Control Network Module
  • Honeywell 10310/1/1 09701 Safety Manager Controller Module
  • Honeywell GR-2C-DC24V Relay Module
  • HONEYWELL GR-4C-DC24V Relay Module
  • Honeywell GR-2C-AC230V Industrial General Purpose Relay
  • Honeywell SPS5713 Power Supply
  • HONEYWELL SC-TCMX01 51307198-175 Termination Module
  • Honeywell 05704-A-0121 05704-A-0122 05704-A-0131 Control Modules
  • Honeywell SC-PCMX01 Power Module
  • Honeywell SPS5785 51198651-100 System Power Supply
  • HONEYWELL CC-IP0101 51410056-175 Interface Module
  • Honeywell 51402455-100 Profibus Module
  • HONEYWELL 51402455-100 MP-DNCF02-200 Module
  • Honeywell 51403645-100 SBHM Static Buffer Hi-Memory Board
  • Honeywell 51401583-100 EPNI Module
  • Honeywell 51306673-100 EPNI Module
  • HONEYWELL 51196655-100 ACX633 Control Module
  • Honeywell 51403519-160 K4LCN-16 Processor Board
  • Honeywell 51305072-200 CLCN-A Module
  • Honeywell 51305896-200 NIM Modem | TDC 3000 Network Module
  • HONEYWELL 51305072-300 CLCN-B Network Module
  • Honeywell FC-PSU-UNI2450U Power Supply
  • Honeywell CC-MCAR02 Series C Carrier | Experion PKS Chassis
  • HONEYWELL SC-UCMX01 51307198-175 Control Module
  • Honeywell 51404170-175 I/O Module
  • Honeywell 51196653-100-RP Controller Processor Board
  • HONEYWELL 05701-A-0330 Gas Detection Control Module
  • Honeywell SPS5710 Power Supply Module
  • Honeywell FTA-T-21 Field Termination Assembly
  • HONEYWELL FTA-T-14 Field Termination Assembly
  • Honeywell 05701-A-0325 I/O Module
  • Honeywell GR-4C-AC230V Industrial Power Relay
  • HONEYWELL PGR-4C-E Ground Fault Protection Relay
  • HONEYWELL CC-TCNT01 Controller Module
  • HONEYWELL CC-TAIX01 Analog Input Module
  • Honeywell CC-TAIN01 Analog Input IOTA Module
  • Honeywell 51304487-100 Output Module
  • Honeywell J-MSC10 Motor Starter Communication Module
  • HONEYWELL 51304518-150 I/O Module
  • HONEYWELL J-DIM00 Digital Input Module
  • HONEYWELL FF-SB12E04K-S2 Safety Light Curtain
  • Honeywell 51404223-001 TDC 3000 Controller Board
  • Honeywell 51195066-100 I/O Module
  • KEBA CU313 Industrial Controller
  • KEBA AR281 Automation Panel
  • KEBA K2-200 CP253/W Central Processor | KeControl CPU Module
  • KEBA CU313A Control Unit
  • KEBA FB201 Fieldbus Interface Module
  • KEBA CU313 Control Unit | KeControl Processing Module
  • KEBA CU312/E Compact Industrial Controller
  • KEBA OP341/Y-1400 Industrial Operator Panel
  • KEBA IP706 Interface Processor Module
  • KEBA CP450 Operator Panel
  • KEBA CP033/Y Industrial HMI Panel
  • KEBA PS244 Power Supply Module
  • KEBA SI232 Safety Input Module
  • KEBA DO321 Digital Output Module | KeControl System
  • KEBA EC100S Industrial Control Module
  • KEBA DI325 Digital Input Module
  • KOLLMORGEN S20330-SRS Compact Digital Servo Drive
  • KOLLMORGEN CB06560 PRD-B040SAIB-62 Servo Drive
  • KOLLMORGEN SAM-DA-400-07B-P4N-F Servo Drive
  • KOLLMORGEN E33NCHA-LNN-NS-00 Servo Motor
  • KOLLMORGEN E33NRHA-LNN-NS-00 Hybrid Stepper Motor
  • KOLLMORGEN CB06251 Digital Servo Drive
  • METSO D201379L Digital Interface Control Module
  • METSO PDP403 24V DC Power Distribution Module
  • METSO D33025 Industrial Control Module
  • METSO D201505 Digital Interface Control Module
  • METSO D201463 Profibus DP Communication Module
  • METSO D201505R Digital Interface Control Module
  • METSO D201380 Industrial Control Module
  • METSO D201139 Fieldbus Communication Interface Module
  • METSO D202214 Industrial Control Module
  • METSO D202275 Digital Interface Control Module
  • METSO D201376 Redundant Communication Interface Module
  • METSO D201134 Industrial Control Module
  • METSO D200175 Digital Interface Control Module
  • METSO D200137 Profibus DP Fieldbus Interface Module
  • METSO IOP353 Industrial I/O Processor Module
  • METSO IOP304 Input/Output Processing Module
  • METSO IOP345 I/O Processor Module
  • METSO IOP114 Industrial I/O Processor Module
  • METSO IOT300A Industrial Internet of Things Gateway Module
  • METSO R/I-TB 9139041 RTD Input Terminal Block
  • METSO IOP303 Industrial I/O Processor Module
  • METSO S422737 Digital Interface Control Module
  • METSO S420061 High-Performance Analog Input Module
  • METSO S420071 Automation Control Module
  • METSO S420154 Interface Control Module
  • METSO A413345 Power Management Module
  • Metso A413177 Digital Interface Control Module
  • METSO A413222 8-Channel Isolated Temperature Input Module
  • Metso A413313 Interface Control Module
  • METSO D100532 Control System Module
  • METSO A413310 8-Channel Digital Output Module
  • METSO A413659 Automation Control Module
  • Metso D100314 Process Control Interface Module
  • METSO A413665 8-Channel Analog Output Module
  • METSO A413654 Automation Control Module
  • Metso A413325 Interface Control Module
  • METSO A413110 8-Channel Analog Input Module
  • METSO A413144 Automation Control Module
  • Metso A413160 Digital Interface Control Module
  • METSO A413152 8-Channel Digital Input Module
  • METSO A413240A Automation Control Module
  • METSO A413146 Digital Interface Control Module
  • METSO A413150 Multi-Role Industrial Automation Module
  • METSO A413125 Automation Control / I/O Module
  • Metso A413111 Interface Control Module
  • METSO A413140 Automation Control Module
  • METSO 020A0082 Pneumatic Control Valve Component
  • METSO 02VA0093 Automation Control Module
  • METSO 02VA0153 Actuator Control Module
  • METSO 02VA0190 Automation Control Module
  • Metso 02VA0193 Pneumatic Control Valve Component
  • METSO 02VA0175 Valve Actuator Module
  • METSO D100308 Industrial Control Module
  • MOOG QAIO2/2-AV D137-001-011 Analog Input/Output Module
  • MOOG D136-002-002 Servo Drive or Control Module