Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Advantest R6244 DC voltage/current source/monitor
    ❤ Add to collection
  • Advantest R6244 DC voltage/current source/monitor

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    Advantest R6244 DC voltage/current source/monitor

    • ¥22500.00
      ¥24520.00
      ¥22500.00
      ¥22500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

Advantest R6244 DC voltage/current source/monitor


Advantest R6244 DC voltage/current source/monitor

DC voltage/current source monitor ideal for electronic circuit/component evaluation by flexible source and measurement 

Wide ranging source/measurement 6243 Voltage: 0 to ±110V Current: 0 to ±2A 6244 Voltage: 0 to ±20V Current: 0 to ±10A 

5½-digit display with 1μV/100pA (6243), 1μV/1nA (6244) resolution in measurement 

Pulse measurement with a minimum pulse width of 1ms 

Sink-enabled bipolar output

The 6243/6244 provides high accuracy with 4½-digit source resolution and 5½-digit measurement resolution, a variety of sweep functions, and a pulse measuring function with a minimum pulse width of 1ms. Thus, it can be used for a wide range of applications as a power source for evaluation in research and development of semiconductors and other electronic components or for characteristic test systems in a production line

For Characteristic Test for Transistor and FET

Synchronized operation of the two units of the 6243/6244 allows characteristic test of a transistor or FET. Id and Ig can be measured simultaneously, as controlling the source timings of drain voltage and gate voltage to protect a device from stress. 

● Linear, log and random sweep functions 

● Pulse measurement with a minimum pulse of 1ms 

● M e a s u r e m e n t d e l ay function for measurement timing control 

● Source delay function for source timing control

For Battery Charge/Discharge Test

The 6243/6244 is available for battery charge and discharge test at constant current (CC) or constant voltage (CV) by DC or pulse application. In a pulse charge and discharge test, measurement must be done at the time of and after the pulse application. Using two units will allow measurement at the two points above and increase the current capacity up to 20A. 

● Source sink current up to ±20A (7V) 

● 20A (6244) and 4A (6243) by two-unit parallel operation 

● Measurement at pulse HI/LO points 

● Selectable from voltage measurement or current measurement

Low Noise

The performance of a power supply basically depends on the accuracy of source voltage/current and the quantity of noise superimposed to them. The 6243/6244 adopts a minimum noise design effective for input signals of a DC amplifier and other cases susceptible to power noise. This model is the perfect power supply for linear ICs, optical devices or mobile communication amplifiers.

For Temperature Dependence Test of Diode VF

In a characteristic test on a power diode, applying pulse current is effective for avoiding the influence of self-heating. The current pulse sweep function and pulse-synchronous voltage measurement ensure accurate VF characteristic test at large current.

For DC/DC Converter Characteristic Test

The following functions are effective for DC/DC converter characteristic test: 

● Parallel measurement of input current and output voltage/current by using two units 

● Electronic load capable of operation down to 0V (General electronic loads do not operate at 0.8V or less.) 

● Large output current up to 10A (7V) (6244)

Main Characteristics

Highly Accurate Measurement:

Featuring up to 4 1/2-bit voltage generation/measurement resolution and 5 1/2-bit current generation/measurement resolution to ensure accurate measurement results.

Voltage source/measurement resolution is 10µV (generation)/1µV (measurement) and current source/measurement resolution is 10nA (generation)/1nA (measurement).

Wide generation/measurement range:

Voltage generation/measurement ranges from 320mV to 20V and current generation/measurement ranges from 32µA to 10A meet the needs of a wide variety of test scenarios.

Multiple scanning functions:

Supports multiple scanning functions such as linear, logarithmic, random, etc., which is convenient for users to carry out characterisation tests.

The minimum pulse width is up to 1ms, which is suitable for applications requiring precise pulse measurement.

Overload and overheat detection function:

Equipped with overload, overheating and other protection functions to ensure safe and stable operation of the equipment under abnormal conditions.

Synchronised operation function:

Two or more R6244 devices can be used in combination to realise the synchronised operation function and improve testing efficiency.

Automated measurement system:

Supporting GP-IB standard, it is convenient to integrate with automated measurement system to achieve automated testing.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System