Basler BE1-87G Generator Differential Relay
The Basler BE1-87G (model G1EA1LA0N1P, part number 9 1708 18 100) is a high-speed, solid-state differential relay specifically designed for the protection of large synchronous generators. This relay provides rapid detection and clearing of internal faults such as phase-to-phase short circuits and turn-to-turn faults, preventing catastrophic damage to the generator. It is widely used in utility and industrial power plants for reliable generator protection.
The BE1-87G features advanced percentage restraint and harmonic restraint techniques to prevent maloperation during external faults and generator start-up. The relay includes a reactor (in some configurations) for additional stability and filtering. It offers adjustable settings for pickup, slope, and time delay, allowing precise coordination with the generator's characteristics.
Technical Specifications
Model: BE1-87G (G1EA1LA0N1P)
Protection type: Percentage differential (87G)
Current sensing: 1/5 A CT inputs
Pickup range: 0.05-2.00 A (adjustable)
Slope setting: 0-40% (adjustable)
Harmonic restraint: Second harmonic (15-30%)
Response time: < 20 ms (typical)
Output contacts: 2 form C (trip and alarm)
Power supply: 24-240 V AC/DC (universal)
LED indicators: Power, pickup, trip
Operating temperature: -40°C to +70°C
Dimensions: 200 x 150 x 80 mm
Certifications: CE, UL, RoHS
Functional Features
Percentage differential protection: Provides sensitive fault detection while maintaining stability for external faults.
Harmonic restraint: Blocks tripping during generator start-up and overexcitation conditions.
Fast operation: Trip times less than one cycle for rapid fault clearing.
Adjustable settings: Pickup, slope, and harmonic restraint can be field-adjusted.
Reactor option: Additional filtering and stability for improved performance in noisy environments.
Typical Applications
Large synchronous generators: Protection of steam, gas, and hydro generators.
Unit-connected generators: Differential protection for generator-transformer units.
Industrial generators: Protection of critical power generation assets.
Installation and Configuration
Mount the BE1-87G on a panel. Connect the CT inputs from the generator neutral and line sides, the power supply, and output contacts. Configure the pickup, slope, and harmonic restraint settings using the front-panel controls. The relay includes test points for verification and a test mode for commissioning.
Compliance
Complies with IEEE C37.91, IEC 60255, CE and UL approved, RoHS compliant.
Conclusion
The Basler BE1-87G provides reliable, high-speed differential protection for large generators, ensuring rapid fault clearing and minimizing damage to critical equipment.