  • Beckhoff C9900-P224 Power Supply Unit 24V 10A
    ❤ Add to collection
  • Beckhoff C9900-P224 Power Supply Unit 24V 10A

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥27455.00
      ¥28456.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:10.500KG
    • Quantity:
    • (Inventory: 5645)
Description
<span style="font-size: 18px; font-family: arial;">Beckhoff C9900-P224 Power Supply Unit 24V 10A</span>

Beckhoff C9900-P224 Industrial Power Supply Unit

The Beckhoff C9900-P224 is a robust power supply unit specifically designed to provide reliable power for Beckhoff Industrial PCs. This compact, DIN rail-mountable unit accepts a wide range of AC input voltages (100‑240 V AC) and converts it to a stable 24 V DC output, making it an essential component for building stable and efficient industrial control systems. A key feature of the C9900-P224 is its capacity to work in conjunction with a C9900-U330 battery pack to create an uninterruptible power supply (UPS). This ensures that the connected PC can safely shut down or continue operating during a mains power failure, protecting against data loss and system crashes. The unit is distinguished by its high efficiency, compact dimensions, and a dedicated UPS output for connecting a control panel.

Technical Specifications

The C9900-P224 power supply unit operates with an input voltage of 100‑240 V AC, accommodating fluctuations commonly found in industrial settings. It is capable of delivering a total power output of up to 150 W, depending on cooling conditions. The primary DC output is 24 V DC with a maximum output current of 10 A, suitable for powering Industrial PCs and other automation components. Additionally, the unit generates other necessary voltages: +5 V, +12 V, and +5 VSB (standby). In conjunction with a C9900-U330 battery pack, it provides an integrated UPS solution. During a power failure, the unit can maintain a display screen for the PC via a dedicated UPS output, which has a maximum load capacity of 1.4 A. The unit’s dimensions are 50 mm (W) × 25 mm (H) × 104 mm (D), and it weighs approximately 120 g. It operates within an ambient temperature range of 0°C to 55°C. The power supply unit must only be used in conjunction with Beckhoff Industrial PCs.

Key Features

  • Universal AC input (100‑240 V AC) for global compatibility

  • 24 V DC output with 10 A capacity, ideal for powering industrial PCs

  • UPS-ready design with C9900-U330 battery pack (sold separately)

  • Dedicated UPS output (1.4 A) for maintaining screen display during power loss

  • Multiple output voltages: +24 V, +12 V, +5 V, and +5 VSB

  • Compact DIN rail mountable design for space-saving cabinet installation

  • High reliability with robust protection against electrical disturbances

  • PC_ON and power status functions for controlled system shutdown


UPS Functionality

The C9900-P224 is a UPS-ready power supply. When combined with the C9900-U330 battery pack, it forms a complete uninterruptible power supply system for Beckhoff Industrial PCs. Upon a power failure, the unit instantly switches to battery power, maintaining the PC‘s operation. The integrated software components allow for a controlled shutdown of the operating system, preventing data corruption. The dedicated UPS output (max. 1.4 A) ensures that the screen display for the PC can be maintained even during a power outage. This feature is particularly valuable in critical automation tasks where loss of control or data could have severe consequences. The unit also provides PC_ON and power status signals, enabling external monitoring of power conditions and system health.

Applications

The C9900-P224 is used as a dedicated power source for Beckhoff Industrial PCs in a wide range of industrial automation applications. Typical use cases include machine control systems in packaging, printing, textile, and woodworking machinery; data acquisition and processing in test stands and measurement systems; operator interface and visualization platforms for manufacturing lines; and edge computing devices in Industry 4.0 architectures. The UPS capability makes it particularly suitable for critical systems where mains power is unreliable or where an orderly shutdown is required to preserve data integrity.


Installation and Wiring

Install the C9900-P224 on a standard 35 mm DIN rail by snapping it into place. Connect the AC input (100‑240 V) to the designated terminals (L, N) according to the installation instructions. Connect the DC output (+24 V and GND) to the Industrial PC’s power input. If a UPS configuration is desired, connect the C9900-U330 battery pack to the dedicated terminals. For external monitoring, connect the PC_ON and power status signals to a PLC or monitoring system. The unit includes a UPS output for connecting a control panel to maintain display during power loss; ensure the load does not exceed 1.4 A. All wiring should be performed with the system power switched off.

Environmental and Compliance

The C9900-P224 is CE and UL certified, and meets FCC Class A digital device limits for industrial environments. It is designed for pollution degree 2 environments and must be installed in a control cabinet with appropriate protection. Operating temperature: 0°C to 55°C. Storage: -20°C to 65°C. Atmospheric humidity: maximum 95%, non-condensing. Sinusoidal vibration (EN 60068-2-6): 10 to 58 Hz: 0.035 mm, 58 to 500 Hz: 0.5 G (~5 m/s²). Impact resistance (EN 60068-2-27): 5 G (~50 m/s²), duration 30 ms. Do not use the power supply unit in areas where there is a risk of explosion.

Conclusion

The Beckhoff C9900-P224 is a high-quality, reliable power supply unit engineered for the rigorous demands of industrial automation. Its UPS-ready design, compact form factor, and robust electrical specifications make it an essential component for any control system that requires a stable and uninterrupted power source for its core computing hardware.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance