  • Yaskawa CIMR-P5C43P7 Inverter 400V 3.7kW
    ❤ Add to collection
  • Yaskawa CIMR-P5C43P7 Inverter 400V 3.7kW

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥41345.00
      ¥44326.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:16.300KG
    • Quantity:
    • (Inventory: 5478)
Description
<span style="font-size: 20px; font-family: arial;">Yaskawa CIMR-P5C43P7 Inverter 400V 3.7kW</span>

Yaskawa CIMR-P5C43P7 400V 3.7kW AC Inverter (P5 Series)

The Yaskawa CIMR-P5C43P7 is a compact, high-performance AC drive belonging to the P5 (or Varispeed P5) series. Designed for three-phase 400V input, it delivers 3.7kW (5 HP) output to standard induction motors. The drive is optimized for variable torque loads such as fans, pumps, and blowers, but also handles constant torque applications like conveyors and mixers. Its built-in PID controller, energy-saving algorithms, and robust PLC I/O interface make it a versatile solution for industrial automation.

Electrical and Power Specifications

  • Rated Motor Power: 3.7 kW (5 HP)

  • Rated Output Current: 9.2 A (constant torque) / 11 A (variable torque)

  • Input Voltage: Three-phase 380–480V AC ±10%, 50/60Hz ±5%

  • Output Frequency Range: 0.1–400 Hz

  • Overload Capacity: 120% for 60 seconds (constant torque), 110% for 60 seconds (variable torque)

  • Carrier Frequency: 2–15 kHz (adjustable, derating above 8 kHz)


Control Methods and Performance

The CIMR-P5C43P7 supports three control modes: V/f control (linear or square), V/f with PG feedback (optional encoder), and sensorless vector control for improved low-speed torque. Sensorless vector provides 150% starting torque at 0.5 Hz. Speed regulation is ±0.5% of base speed with slip compensation enabled. The drive includes an automatic torque boost that adjusts voltage at low frequencies to overcome static friction.

Built-in PID Control

A dedicated PID controller is integrated, accepting feedback from a 4-20mA or 0-10V transducer (pressure, flow, temperature). The PID setpoint can come from an analog input or a PLC via serial communication. The drive features sleep and wake-up functions to save energy during low demand (e.g., pump systems). PID output limits, anti-windup, and direct/reverse action are programmable.

I/O and PLC Integration

The drive provides: 7 digital inputs (24V DC, programmable for run/stop, multi-speed, JOG, fault reset, PID enable), 3 relay outputs (250V AC, 2A) for run status, fault, and frequency agree; 2 analog inputs (0–10V or 4-20mA selectable) for speed reference and PID feedback; 2 analog outputs (0–10V) for output frequency and current monitoring. A built-in RS-485 port supports Modbus RTU and Yaskawa's MEMOBUS protocol, allowing a PLC to read/write all parameters, start/stop the drive, and monitor real-time data such as frequency, current, and power.

Energy Saving Features

The CIMR-P5C43P7 includes an energy-saving algorithm that reduces motor voltage based on load torque, achieving up to 30% energy savings compared to fixed speed operation. For variable torque loads (fans/pumps), the square V/f profile matches the motor's cubic torque curve, further reducing losses. A built-in energy monitor displays cumulative power consumption (kWh) and CO₂ reduction estimates, which can be read by a PLC for energy management systems.

Protection and Reliability

Protections include: overcurrent (instantaneous and time-delayed), overvoltage (DC bus > 800V), undervoltage (< 380V), motor overload (electronic thermal), drive overload, ground fault, output short circuit, and heatsink overtemperature (thermistor). The drive also features a stall prevention function that automatically reduces frequency during excessive current or voltage. An optional braking transistor is built-in for models up to 3.7kW, with an external braking resistor available for high-inertia loads.

Mechanical Dimensions and Installation

Dimensions: 250mm (H) × 140mm (W) × 155mm (D). Weight 3.2 kg. Mounting by four M5 screws on a vertical panel. Ambient temperature range: -10°C to +50°C (derate above 40°C at 2.5%/°C). Humidity: 20–90% non-condensing. Altitude up to 1000m without derating. Enclosure IP20 (open type) requires installation in a pollution degree 2 environment.


Applications in PLC-Controlled Systems

Common applications include: HVAC fans and pumps controlled by building automation PLCs, conveyor belt drives with speed changes via analog output from a PLC, and extruder drives requiring precise speed regulation. The drive's multi-speed function (up to 16 preset speeds via digital inputs) allows a simple PLC with only digital outputs to select speeds without analog modules. The built-in PID is often used to control pump discharge pressure using a PLC as a supervisory setpoint generator.

Standards and Compliance

The CIMR-P5C43P7 complies with CE (EMC Directive EN 61800-3, Low Voltage Directive EN 61800-5-1), UL 508C, cUL, and RoHS. It meets the harmonic standard EN 61000-3-2 with optional input filter. The drive is rated for pollution degree 2 and overvoltage category III.

Conclusion

The Yaskawa CIMR-P5C43P7 400V 3.7kW inverter delivers reliable motor control with energy-saving features, flexible I/O, and easy PLC integration. Its robust design and protection suite make it a cost-effective choice for fan, pump, and light industrial conveyor applications.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide