Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • OMRON CS1W-AD081-V1 Analog Input Module
    ❤ Add to collection
  • OMRON CS1W-AD081-V1 Analog Input Module

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥34627.00
      ¥37845.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.450KG
    • Quantity:
    • (Inventory: 6457)
Description
<span style="font-size: 20px; font-family: arial;">OMRON CS1W-AD081-V1 Analog Input Module</span>

OMRON CS1W-AD081-V1 Analog Input Module

The OMRON CS1W-AD081-V1 is a high-performance analog input module for the SYSMAC CS1 series PLC platform. This Special I/O Unit provides 8 analog input channels with selectable voltage and current ranges, 16-bit resolution, and fast conversion times for precision measurement applications in industrial automation and process control.

Product Overview

The CS1W-AD081-V1 belongs to the CS-series Analog I/O Unit family, which provides comprehensive analog measurement capabilities for CS1 and CS1D PLC systems. This module is designed to convert analog signals from field sensors and transmitters into digital values that can be processed by the PLC CPU. The module supports eight independent input channels, allowing a single unit to monitor multiple analog points while minimizing rack space utilization.

The module complies with international standards including CE, UL, and CUL certifications, ensuring suitability for global industrial applications. The V1 designation indicates a specific revision level of the module's hardware and firmware design.


Input Signal Specifications

The CS1W-AD081-V1 supports five selectable input signal ranges that can be configured independently for each of the eight channels:

  • 1 to 5 VDC

  • 0 to 5 VDC

  • 0 to 10 VDC

  • -10 to +10 VDC (bipolar)

  • 4 to 20 mA (current loop)

The module provides 16-bit resolution across the selected input range, delivering 1/4,000 resolution with the capability to be set to 1/8,000 for applications requiring even finer measurement granularity. The conversion time is 1 millisecond per input channel, with the ability to set the conversion speed to 250 microseconds per input for applications requiring faster data acquisition rates.

Accuracy and Performance

The CS1W-AD081-V1 delivers exceptional measurement accuracy of ±0.1% of full scale, ensuring reliable and repeatable data acquisition for critical process measurements. Input impedance for voltage signals is greater than 1 MΩ, minimizing loading effects on the signal source and preserving signal integrity. For current inputs, the impedance is 250 Ω, which is appropriate for standard 4-20 mA current loop instruments.

The module includes channel error detection diagnostics that enhance system reliability by allowing users to quickly identify issues with specific input channels. This diagnostic capability simplifies troubleshooting and reduces system downtime when measurement problems occur.

External Connections and Power Requirements

The CS1W-AD081-V1 uses a removable terminal block for external wiring, facilitating installation and simplifying module replacement during maintenance. The terminal block arrangement accommodates wiring for eight analog input channels plus associated common and shielding connections. The module's external connection design supports both voltage and current input configurations, with appropriate jumper settings or wiring arrangements to select the desired input type for each channel.

The module is assigned two unit numbers in the CS1 series I/O allocation system. Current consumption from the PLC backplane is 0.12 A at 5 VDC, with additional consumption of 0.09 A at 26 VDC for the analog input circuits. The module should be installed in a CS1 or CS1D PLC rack following standard installation procedures.

Applications

The CS1W-AD081-V1 is ideally suited for industrial and process control applications requiring accurate measurement of analog signals. Typical applications include temperature monitoring using thermocouples or RTDs with signal conditioners, pressure and flow measurement using 4-20 mA transmitters, level monitoring in tanks and silos, position feedback from potentiometers or LVDTs, and voltage monitoring from power supplies or generators. The eight-channel configuration allows comprehensive monitoring of multiple process variables from a single module, reducing system cost and complexity.


HONEYWELL FC-SAI-1620M 16-Channel Universal Analog Input Module
REM630 1KHL178082R0001 Numerical Motor Protection Relay
RET543 1MRS050638 Numerical Feeder Protection and Control Relay
MC422B/CC422 ID Nr387 189-01 Industrial Sensor Module or Control Relay
GE PCIE-5565PIORC Reflective Memory Network Interface Card (NIC)
LAM 810-240888-002 RF Matching Network / Power Delivery Sub-Assembly
WOODWARD A8516-038 Servo Actuator Control Module / Servo Drive
GE IS220PPROH1A PROFIBUS DP Remote I/O Interface / Head Module
LAM 810-800082-009 Gas Delivery System Sub-Assembly
NBIO-21CU 3BSE017427R1 Combination Module (Network Interface + Local I/O)
Fireye 85UVF1-1Ex Multi-Spectrum (UV/IR) Flame Detector, Intrinsically Safe
Fireye 85UVF1-1QD Multi-Spectrum (UV/IR) Flame Detector
Fireye 45UV5-1101CEX Ultraviolet (UV) Flame Detector
KONGSBERG MRU-M-MB2 Motion Reference Unit (MRU) / Attitude and Heading Reference System (AHRS)
ABB SYMPHONY PLUS-RFO810 Remote Fieldbus I/O Module / Communication Interface
GE IS420ESWAH1A Managed Industrial Ethernet Switch Module (for Mark VIe/VIeS systems)
YOKOGAWA PW482-53 Loop-Powered Isolator with Intrinsic Safety (IS) Approval
YOKOGAWA PW482-50 High-Performance Loop-Powered Isolator
HONEYWELL FS-FEEDER-24R Fire System Power Supply / Battery Charger Module
ABB ICST08A9 Isolated Current Sensor / Transducer Module         
  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance