Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS3800HCIB Turbine Control Board
    ❤ Add to collection
  • GE DS3800HCIB Turbine Control Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS3800HCIB Turbine Control Board

    • ¥22500.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS3800HCIB Turbine Control Board


GE DS3800HCIB Turbine Control Board

Part Number DS3800HCIB Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS3800HCIB is a turbine control board developed by GE. It is a part of Mark IV control system. As part of the Mark IV control system, the board integrates seamlessly with other control components and subsystems, forming a comprehensive control and monitoring solution for turbine-driven systems. With its robust design and state-of-the-art technology, the component offers a wide range of features that contribute to the optimal performance of the turbine system. It enables precise control over various turbine parameters, such as speed, temperature, pressure, and flow. 

It continuously monitors these parameters to ensure that the turbine operates within safe and efficient operating limits. Features Modular Connector and Retention Levers: The board is equipped with a modular connector that enables seamless connection to a compatible drive. Additionally, retention levers are provided to securely hold the board in place within the drive. These levers ensure a stable and reliable connection, preventing accidental dislodging. Jumper and Indicator LED: The board is populated with one jumper, which allows for configuration or customization of specific settings on the board. Additionally, there is an amber indicator LED that provides visual feedback or status indication. 

20-pin and 50-pin Connectors: The board features a 20-pin connector and a 50-pin connector. These connectors serve as interfaces for connecting various external devices or components to the board. The operator has convenient access to these connectors when the board is mounted in the rack, facilitating easy connection and disconnection of cables. Capacitors: The board includes numerous capacitors, which are passive electronic components used to store and release electrical energy. Capacitors play a vital role in smoothing out voltage fluctuations and stabilizing the power supply within the control system. Ribbon Cable Considerations: Before installing the ribbon cables, there are certain factors to consider. 

It is important to ensure proper routing of the cables to avoid obstructing airflow within the drive. Incorrect cable placement can restrict the circulation of air and potentially impact the cooling efficiency of the system. Proper cable management and routing are essential for maintaining optimal airflow and preventing overheating issues. Operating Interface Multiple Displays: The operating interface includes multiple displays that provide real-time information about the system's logic, switches, internal components, output relay status, sensors, and actuators. These displays offer a holistic view of the turbine control system, allowing operators to monitor various parameters and statuses simultaneously. 

Logic and Parameter Presentation: The displays present detailed information regarding the logic of the control system. This includes the values of turbine-mounted switches, internal logic elements, and the status of output relays. Furthermore, the interface also presents the values of sensors and actuators, enabling operators to monitor their performance and ensure optimal functionality. Display Menu: The operating interface incorporates a menu system that allows users to select specific pages or screens to view the desired information. The menu provides easy navigation and access to the various display options available. Users can choose specific pages to focus on different aspects of the control system, such as alarms, status overviews, or specific control parameters. Copying Displays: To facilitate documentation or record-keeping, the operating interface includes a roll-out printer feature. 

By pressing the designated "Copy" button, users can easily generate printed copies of the displayed information. This feature allows for convenient archiving or sharing of critical data and system status reports. Display Variety: The operating interface boasts an extensive library of approximately 200 pages or screens. While it is not possible to describe all of them in detail, the interface offers a diverse range of display options catering to various aspects of the control system. These pages can include detailed status information, control parameters, graphical representations, alarms, and troubleshooting data. 

Enhanced Accessibility and Troubleshooting: One significant advantage of the operating interface is that it reduces the need for users to physically access the Mark IV panel for adjustments or fault troubleshooting. The comprehensive displays provide detailed information, allowing operators to identify issues, monitor system performance, and make informed decisions without requiring direct access to the control panel. This enhances convenience, safety, and efficiency during routine operations and maintenance tasks.

APPLICATIONS

• Simulation 

• Instrumentation 

• Industrial control 

• Process control and monitoring 

• Factory automation 

• Intelligent networked PLC controllers 

• Automated test 

• Data acquisition

 



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide