  • GE VMIVME-4105 Digital-to-Analog Converter Board
    ❤ Add to collection
  • GE VMIVME-4105 Digital-to-Analog Converter Board

    GE VMIVME-4105 Digital-to-Analog Converter Board

    • ¥25650.00
      ¥25520.00
      ¥25650.00
      ¥25650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.600KG
    • Quantity:
    • (Inventory: 56)
Description

GE VMIVME-4105 Digital-to-Analog Converter Board


GE VMIVME-4105 Digital-to-Analog Converter Board

Analog Output Testing: 

Any one of the eight analog  outputs may be switched to the analog output test bus  (Test Bus 2). This bus is routed through the P2 AMXbus  analog backplane to an Analog-to-Digital Converter  (ADC) board which is used to verify each DAC channel  on the VMIVME-4105 board.

Compatibility: 

The VMIVME-4105 Analog Output  Board is a standard, double height, printed circuit board  which is compatible with the VMEbus specification.

Board Address: 

The physical address for the board  may be selected through a 12-bit DIP switch. VMEbus  address lines A04 through A15 are decoded for board  selection.

Test Mode: 

The DAC board may be used in  conjunction with other VMIC boards and the VMIC  AMXbus™ backplane for extensive fault detection and  isolation. There are two dedicated analog buses that are  used by the DAC board.

Tests may be performed by utilizing any one of the eight  DAC outputs. While in a test mode the eight DAC  outputs may be isolated from the P3 connector so that  user-connected devices are not affected by worst-case  testing in an off-line mode. Real-time fault detection and  isolation is not supported if the multiplying DAC option  is used. Built-in-Test is not supported if P2 outputs are  used.

Analog Input Test Mode: 

Any one of the eight analog  outputs may be switched to an analog test bus  (Test Bus 1). This analog bus may be used to verify the  operation of a VMIC Multiplexer Expansion Board  (VMIVME-3200A) that is designed to support  Built-in-Test. The interconnecting of the analog bus  between boards may be accomplished by using one of  VMIC’s 5-, 9-, or 19-slot AMXbus backplanes.

Data Transfer: 

When a board write operation is  executed, the destination of the data is controlled by data  bit 15. If data bit 15 is a one, the word is written to the  Control Register. When data bit 15 is a zero, the data is  written to the Digital-to-Analog Converter (DAC) that is  addressed. Executing a read access to any valid board  address will allow the user to read the board status.  Digital data to the DAC is contained in data bits D00  through D11. Unipolar binary code is used for unipolar  operation (0 to -10 V output). Bipolar operation (-10 to  +10 V output) may use either offset binary or two’s  complement code.

Mode Selection: 

The operation modes of the board  may be selected by writing to the Control Register. Only  data bits D08 through D14 are utilized for the Control  Register. Data bits D08 through D14 contain information  to select the different DAC operation modes.

SPECIFICATION

Temperature:0 to +55 °C, operating -20 to +85 °C, storage

Humidity: 20 to 80 percent relative, noncondensing

Altitude: Operation to 10,000 ft

Cooling: Forced air convection

Dimensions: Double Eurocard (6U) 160 x 233.35 mm

FEATURES

• 8-channel analog output (D/A per channel) 

• Jumper-selectable P2 or front panel outputs 

• 12-bit resolution 

• 2- or 4-quadrant multiplier jumper-selectable option 

• Jumper option to support eight independent or one shared AC or DC voltage  reference 

• ±10 V or 0 to -10 V jumper-selectable options 

• Double Eurocard format with front panel fail LED  

• Requires VMIVME-31xx for Built-in-Test 

• Multiplexed programmable outputs for testing analog outputs 

• Internal DC reference to support Built-in-Test

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide