Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS410JPDDG1A - DC PDM
    ❤ Add to collection
  • GE IS410JPDDG1A - DC PDM

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS410JPDDG1A - DC PDM
    • ¥11000.00
      ¥34670.00
      ¥11000.00
      ¥11000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS410JPDDG1A - DC PDM

GE IS410JPDDG1A - DC PDM

Part Number IS410JPDDG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockCopyright  2024 - Unisys Group. All Rights Reserved.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

Features 

▪ Contains 10 Mbytes of battery-backed user memory and 10 Mbytes of non-volatile flash user  memory. 

▪ Provides access to bulk memory via reference table %W. 

▪ Configurable data and program memory. 

▪ Programming in Ladder Diagram, C, Structured Text, and Function Block Diagram. 

▪ Supports auto-located Symbolic Variables that can use any amount of user memory. 

▪ Reference table sizes include 32Kbits for discrete %I and %Q and up to 32K words each for  analog %AI and %AQ. 

▪ Supports Series 90-70 discrete and analog I/O, communications, and other modules. For a  list of modules supported, refer to the PACSystems RX7i Installation Manual, GFK-2223. 

▪ Supports all VME modules supported by Series 90-70. 

▪ Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server  and FTP connections. 

▪ Supports up to 512 program blocks. Maximum size for a block is 128KB. 

▪ Test Edit mode allows you to easily test modifications to a running program. 

▪ Bit-in-word referencing. 

▪ Battery-backed calendar clock. 

▪ In-system upgradeable firmware. 

▪ Three isolated serial ports: an RS-485 serial port, an RS-232 serial port, and an RS-232  Ethernet station manager serial port. 

▪ The embedded Ethernet interface provides: 

- Data exchange using Ethernet Global Data (EGD) 

- TCP/IP communication services using SRTP 

- Support for SRTP Channels, Modbus/TCP Server, and Modbus/TCP Client 

- Full programming and configuration services 

- Comprehensive station management and diagnostic tools 

- Two full-duplex 10BaseT/100BaseT/TX (RJ-45 Connector) ports with an internal network  switch providing auto-negotiated network speed, duplex mode, and crossover detection. 

- User-configurable Redundant IP address 

- Time synchronization to SNTP time server on Ethernet network (when used with  Release 5.00 or later CPU module).

Compatibility 

ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page. 

ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU. 

ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0). 

ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software. 

ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network. 

Module features include: 

ƒ Support for all standard data rates (125K, 250K, 500K) 

ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave 

ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master 

ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS 

ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging 

ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device 

ƒ Support for configuration of the global scan rate 

ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis 

ƒ Support for PLC-application initiated explicit messaging via a COMMREQ 

ƒ Master can be configured to operate as a slave simultaneously with master operation 

ƒ Configurable fault behavior on loss of communication 

ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable) 

ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero) 

ƒ Firmware update via service port on module


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Watlow F4T Controller Installation and Failure
  • Watlow DIN-A-MITE ® Style C Solid State Power Controller
  • Watlow plug-in heater
  • Watlow Series 942 Controller
  • Watlow Series 988 Controller
  • Watlow Series 146 Temperature Regulator
  • Watlow PM LEGACY ™ Limit controller
  • How to install Johnson AE55/NIE55?
  • Watlow Series 96 Temperature Controller
  • Watlow PM PLUS ™ PID/Integrated Limit Controller
  • Watlow Ceramic Fiber Heater
  • Watlow Power Series microprocessor based SCR power controller
  • Watlow thermocouple products
  • Watlow Series 965 Controller
  • Watlow PM3 LEGACY ™ PID controller
  • Watlow Series 93 Controller
  • Watlow EZ-ZONE ® PM PID controller
  • Watlow CLS200 series controller
  • YAMAHA RCX40 4-axis robot controller
  • YASKAWA Z1000 series HVAC dedicated frequency converter
  • YASKAWA HV600&Z1000U series HVAC dedicated frequency converter
  • YASKAWA Power Regenerative Unit R1000 Series
  • YASKAWA AC Drive P1000 Industrial Fan and Pump Special Frequency Converter
  • YASKAWA FP605 series industrial fan pump dedicated driver
  • YASKAWA GA500 series AC micro driver
  • YASKAWA AC Drive G7 Series (Model CIMR-G7U)
  • YASKAWA U1000 series 24V power supply options (PS-U10L/PS-U10H)
  • YASKAWA GA800 industrial AC frequency converter Key issues
  • How to select YASKAWA GA800 industrial AC frequency converter?
  • YASKAWA AC Drive V1000 Compact Vector Control Drive
  • YASKAWA Control Pack CP-317M System Controller
  • YASKAWA VARISPEED-626M/656MR5 series vector control frequency converter
  • YASKAWA AC Servo Drive HR Series (CACR-HR) Multi functional/Positioning Control
  • YASKAWA MP2000 series machine controller communication module
  • Yokogawa AQ1100 series OLTS multi field tester
  • YOKOGAWA AQ7280 Optical Time Domain Reflectometer
  • YOKOGAWA AQ2200 Series Multi Application Testing System
  • YOKOGAWA AQ6150B/AQ6151B Optical Wavelength Meter
  • YOKOGAWA AQ6360 Optical Spectrum Analyzer
  • Yokogawa AQ6375E Spectral Analyzer Remote Control
  • Yokogawa DL350 Scope Order Communication Interface
  • Yokogawa 701944/701945 100:1 High Voltage Probe
  • Yokogawa CA700 pressure calibrator
  • Yokogawa DLM5000HD series high-definition oscilloscope
  • Yokogawa AQ1210 Series OTDR Multi Field Tester
  • Yokogawa AQ1000 OTDR Optical Time Domain Reflectometer
  • YOKOGAWA WT1801R series precision power analyzer communication interface
  • YOKOGAWA DLM3034HD/DLM3054HD High Definition Oscilloscope
  • YOKOGAWA AQ23011A/AQ23012A Modular Framework Equipment
  • YOKOGAWA DLM3054HD Mixed Signal Oscilloscope
  • YOKOGAWA CW500 Power Quality Analyzer
  • How to troubleshoot the YOKOGAWA CA500/CA550 multifunctional process calibrator?
  • How to maintain YOKOGAWA AQ7420 High Resolution Reflectometer?
  • YOKOGAWA FG410/FG420 arbitrary waveform editor
  • How to check the packaging and accessories of Yokogawa Model 701905 conversion cable?
  • YOKOGAWA MY600 Digital Insulation Resistance Tester
  • YOKOGAWA AQ7290 Series Optical Time Domain Reflectometer OTDR
  • How to ensure the safety and maintenance of YOKOGAWA LS3300 AC power calibrator?
  • Yokogawa AQ6377E Optical Spectrum Analyzer Remote Control
  • Yokogawa AQ6361 Optical Spectrum Analyzer
  • Yokogawa IS8000 Integrated Software ECU Monitoring and Synchronization Function
  • Yokogawa ROTAMASS TI Coriolis Mass Flow Meter
  • Yokogawa ROTOMETER RAMC Metal Variable Area Flow Meter
  • Yokogawa SL1000 high-speed data acquisition unit input module
  • How to install and wire the Yokogawa FLXA402T turbidity and chlorine liquid analyzer?
  • Yokogawa WTB10-DO Series Dissolved Oxygen Measurement System Terminal Box
  • Yokogawa Model 702928 PBD0200 Differential Probe
  • YOKOGAWA ADMAG TI Series AXW Electromagnetic Flow Meter (25-450mm) Installation and Operation
  • How to troubleshoot YOKOGAWA ADMAG TI series AXW electromagnetic flowmeter (25-1800mm)?
  • How to install YOKOGAWA DO30G dissolved oxygen sensor?
  • YOKOGAWA SC4AJ Conductivity Sensor Manual
  • YOKOGAWA SC210G Conductivity Detector
  • How to install and wire Yokogawa PH4/OR4 series pH and ORP sensor (IM12B10B00-01EN)?
  • How to troubleshoot Yokogawa OR8EFG KCl filled ORP sensor (IM12C07J01-01E)?
  • YOKOGAWA FU24 pH/ORP Composite Sensor with Pressure Compensation (IM 12B06J03-03EN-P)
  • Yokogawa SC200 Intelligent Two Wire Conductivity Transmitter System (IM12D08B01-01E)
  • YOKOGAWA CENTUM VP Integrated Production Control System (TI33J01A10-01EN)
  • ABB AO2000-LS25 Laser Analysts User Manual
  • YOKOGAWA FA-M3 positioning module (with analog voltage output)
  • YOKOGAWA FA-M3 Series Basic Modules
  • YOKOGAWA EJA110E Diff erential Pressure Transmitter
  • Zygo 3D Optical Profiler
  • How to unpack and install the Zygo Mark II 4-inch interferometer system?
  • Zygo NewView 9000 3D Optical Profilometer Technology Advantages
  • Zygo NewView 9000 3D Optical Profilometer Technology
  • Zygo Profilometer Standard Operating Procedure
  • Zygo’s Guide to Typical Interferometer Setups
  • ZYGO Laser Interferometer Accessory Guide OMP-0463AM
  • ZYGO MetroPro 9.0 Reference Guide (OMP-0347M)
  • Zygo Device Standard Operating Procedure (SOP)
  • Zygo Verify Laser Interferometer Product Highlights
  • Zygo MicroLUPI Micro Hole Diameter Laser Unequal Path Interferometer
  • ZYGO ZMI-1000 Displacement Measuring Interferometer System
  • Zygo’s ZMI 2000 System Displacement Measuring Interferometer Systems
  • ABB IGCT Technology: A Revolutionary Breakthrough in High Voltage Inverters
  • Siemens 6AG1204-2BB10-4AA3 Ethernet Switch
  • Siemens 6ES7193-4JA00-0AA0 Terminal Module
  • Siemens ET200SP 6ES7193-6PA00-0AA0 server module
  • Siemens 6ES7231-0HC22-0XA0 Analog Input Expansion Module
  • Siemens 6ES7350-2AH01-0AE0 Counter Module
  • Siemens 6ES7421-7DH00-0AB0 Digital Input Module
  • Siemens 6AV2124-2DC01-0AX0 Comfort Panel
  • Siemens 6ES7193-4CA40-0AA0 ET 200S Electronic Module
  • STOBER POSIDRIVE ® How to install MDS 5000?
  • Siemens 7XV5653-0BA00 dual channel binary signal transmitter
  • Thinklogical Velocity KVM-34 series KVM fiber extender
  • Watlow MLS300 Series Controller
  • ​DHR NLS3000 NLC System (Navigation Control System)
  • Watlow Anafaze CLS200 Series Controller
  • CyberPower UT650EG / UT850EG User’s Manual
  • Thermal Solutions EVS series gas regulated boilers
  • Bosch Rexroth HM20 Hydraulic Pressure Sensor
  • ABB SPAU 341 C Voltage Regulator
  • Rockwell Automation 1585 Ethernet Media
  • Rockwell Automation SmartGuard 600 Controller
  • Rockwell Automation 1756 ControlLogix Communication Module
  • Rockwell Automation Stratix series Ethernet devices
  • A-B Ultra3000 and Ultra5000 with DeviceNet
  • ABB INNIS21 Network Interface Slave module
  • DEIF Undervoltage and overvoltage relay type RMV-112D
  • SAUTER AVM 234S valve actuator (with positioner)
  • REXRTOH INDRAMAT TVD 1.3 power module
  • Honeywell Expert Series-C I/O Module
  • GE PACSystems RX7i power module (IC698PSA100/350 series)
  • Yokogawa AFV40S/AFV40D Field Control Unit (FCU)
  • Schneider 31H2S207 FBM207/b/c Voltage Monitor/Contact Sense Input Modules
  • Emerson DeltaV™ S-series Traditional I/O
  • MKS Type T3B Butterfly Valve (with DeviceNet Interface)