  • Kongsberg NK-210 NU02 Control Panel
    ❤ Add to collection
  • Kongsberg NK-210 NU02 Control Panel

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥22316.00
      ¥24367.00
      ¥22316.00
      ¥22316.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.620KG
    • Quantity:
    • (Inventory: 3462)
Description
<span style="font-size: 20px; font-family: arial;">Kongsberg NK-210 NU02 Control Panel</span>

Kongsberg NK-210 NU02 Control Panel

The Kongsberg NK-210 NU02 is a rugged operator interface panel designed for marine and offshore automation systems. This compact control station provides reliable manual control and status indication for machinery, propulsion, and auxiliary systems. The NK-210 NU02 is engineered for installation in engine control rooms, bridge consoles, and local control stations where dependable operator interface is essential for safe vessel operation.


Key Features

  • Durable construction for marine environment

  • Backlit pushbuttons with tactile feedback

  • LED status indicators for system monitoring

  • Configurable panel layouts for specific applications

  • IP66 front panel protection for water and dust resistance

  • Compatible with Kongsberg K-Chief automation systems


Operator Interface

The NK-210 NU02 provides a comprehensive operator interface with a combination of illuminated pushbuttons, toggle switches, and status indicators. Each control element is clearly labeled for its specific function, enabling intuitive operation without extensive training. The backlit buttons provide visibility in low-light conditions common during night operations. Tactile feedback ensures operators receive confirmation of successful actuation.

Functional Capabilities

Typical control functions implemented on the NK-210 NU02 include:

  • Start and stop commands for engines and pumps

  • Mode selection for automatic or manual operation

  • Alarm acknowledgment and silencing

  • Emergency stop and override functions

  • Local remote transfer switches

  • Status indication for running, stopped, and fault conditions

Electrical Specifications

  • Power supply: 24 V DC (18 to 32 V DC)

  • Power consumption: < 5 W typical

  • Inputs: Dry contact or 24 V DC sinking/sourcing configurable

  • Outputs: Relay or solid-state for status indication

  • Communication: Direct I/O wiring or serial interface options

  • Protection: Reverse polarity and transient suppression

Integration with Automation Systems

The NK-210 NU02 is designed for seamless integration with Kongsberg K-Chief and other marine automation platforms. The panel connects to the automation system through discrete I/O wiring or via serial communication where supported. In discrete I/O configuration, each pushbutton and indicator is wired to specific input and output channels of the automation controller. This approach ensures reliable operation independent of network communications.

Physical Construction

The NK-210 NU02 is housed in a robust metal enclosure with a powder-coated finish for corrosion resistance. The front panel meets IP66 ingress protection, allowing installation in areas exposed to water spray and dust. The rear of the panel is IP20 protected for installation inside control cabinets. The panel can be flush-mounted with a sealing gasket or surface-mounted using optional mounting brackets. All connections are made via pluggable terminal blocks for simplified wiring and maintenance.


Environmental Specifications

  • Operating temperature: -15°C to +55°C

  • Storage temperature: -25°C to +70°C

  • Relative humidity: 10% to 95% non-condensing

  • Vibration: IEC 60945 compliant

  • EMC: EN 60945 for marine navigation and control equipment

Applications

The NK-210 NU02 is suitable for a variety of marine and offshore applications:

  • Engine control room panels for start-stop and status

  • Bridge wing control stations for maneuvering

  • Local control stations for pumps and compressors

  • Thruster and propulsion control interface

  • Alarm and monitoring system annunciation

  • Generator and power management control


Certifications

The NK-210 NU02 is type-approved by major classification societies including DNV, Lloyd’s Register, ABS, and Bureau Veritas. It complies with IMO, SOLAS, and IEC 60945 requirements for marine equipment. The panel is manufactured under ISO 9001 quality management systems.

Installation and Commissioning

Installation involves panel mounting, wiring connections, and functional testing. The panel should be installed in a location accessible to operators and protected from direct water exposure. Wiring should be routed away from high-voltage cables to minimize interference. After installation, each control function should be verified against the automation system. Configuration of the connected automation controller is required to map the panel inputs to system functions.

Maintenance

The NK-210 NU02 requires minimal maintenance. Periodic inspection should verify the integrity of panel seals, cleanliness of controls, and security of wiring connections. The backlit elements have an expected service life exceeding 50,000 hours. Replacement of individual switches or indicators can be performed if needed, with spare parts available from Kongsberg.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector