Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • NLTECH NL8060AC21-21D 8.4 inch LCD Display
    ❤ Add to collection
  • NLTECH NL8060AC21-21D 8.4 inch LCD Display

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42462.00
      ¥45364.00
      ¥42462.00
      ¥42462.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:7.450KG
    • Quantity:
    • (Inventory: 5351)
Description
<span style="font-size: 18px; font-family: arial;">NLTECH NL8060AC21-21D 8.4 inch LCD Display</span>

NLTECH NL8060AC21-21D 8.4 Inch Industrial LCD Display Module

The NLTECH NL8060AC21-21D (formerly manufactured by NEC under the NLT brand, with technical data also supported by Tianma) is an 8.4 inch a-Si TFT-LCD module designed for industrial applications. This high-quality display delivers SVGA (800 x 600 pixel) resolution with excellent brightness and contrast characteristics, making it suitable for medical equipment, industrial control panels, kiosk displays, and transportation applications. The orientation and resolution support both landscape operation and functional integration into existing graphical interfaces.

Display Performance

The NL8060AC21-21D features SVGA resolution of 800 x 600 pixels with RGB vertical stripe pixel arrangement, providing 119 pixels per inch density. Display area measures 170.4mm (horizontally) by 127.8mm (vertically), with a 4:3 aspect ratio that matches many legacy industrial interfaces. Active area dimensions support both full-screen and windowed content, and the LVDS interface provides high-speed digital video transmission for crisp, interference-free imaging. Viewing angles are specified at 80 degrees in all directions (left/right/up/down) at CR≥10, enabling readability from multiple operator positions. Response time is 3ms turn-on and 15ms turn-off (Typ.). The screen topology supports high-vibration environments and typical industrial working distances.

Optical Specifications

Luminance (brightness) is rated at 400 cd/m², ensuring good visibility in moderately lit industrial environments. Contrast ratio is specified at 800:1 (min 500:1 typical), providing sharp differentiation between light and dark areas of the display. Anti-glare surface treatment reduces reflection from overhead lighting and windows that may cause operator fatigue during extended use. Color reproduction supports 262K colors (6-bit per color) or 16.7M colors (6-bit + Hi-FRC), with color saturation of approximately 40% NTSC. The optical stack and inherent ColorXcell technology improve both brightness and color consistency to support high-information interfaces containing both text and graphical elements.


Backlight System

The display features a white LED backlight system with integrated driver board, eliminating the need for external inverter circuits. Backlight lifetime exceeds 100,000 hours under standard operating conditions, reducing maintenance requirements for applications requiring continuous operation. The integrated driver simplifies system design and reduces component count. Backlight power consumption is managed via the integrated controller, allowing for dynamic control of brightness without external brightness control modules.

Interface and Connectivity

The NL8060AC21-21D utilizes an LVDS (Low-Voltage Differential Signaling) interface for high-speed digital video transmission. This interface provides excellent noise immunity and supports longer cable lengths than parallel RGB interfaces. Signal input is single-channel 6-bit LVDS per the standard pinout, ensuring compatibility across a wide ecosystem of industrial controllers. The backlight driver is included and integrated into the module, with LED drive signals carried through the main connector. The input voltage range and typical current consumption are consistent with industry standards for 8.4-inch LVDS modules.

Construction and Mounting

The module is constructed as an a-Si TFT-LCD with normally white transmissive operation. The display is a liquid crystal module (LCM) using active matrix TFT (Thin Film Transistor) technology for pixel control. External dimensions are 200mm width by 152mm height, with overall thickness of 8.2mm (plus 0.5mm tolerance). Weight is approximately 260 grams. Face mounting holes (4 pieces) are provided on the left and right bezel edges for secure attachment to equipment enclosures, satisfying standard vibration specifications. The panel has a 4:3 physical aspect ratio, matching the pixel geometry for true-to-source image presentation without hardware scaling artifacts.

Environmental Specifications

The NL8060AC21-21D is built to withstand demanding industrial conditions. Operating temperature range spans from -30°C to +80°C, while storage temperature also ranges from -30°C to +80°C, allowing deployment in unheated or outdoor enclosures and warehouses. The wide temperature range ensures reliable operation in extreme environments where standard commercial displays would fail. Vibration resistance is rated at 2.0G (19.6 m/s²), suitable for vehicle-mounted and mobile equipment applications. RoHS compliance ensures adherence to environmental regulations across worldwide markets.


Additional Features

ColorXcell technology embedded in this model improves perceived color performance for business graphics and control panels. The display supports 180-degree rotation capability, allowing flexible installation orientation and simplifying integration into existing mechanical designs. Both 6-bit and 6-bit + Hi-FRC are supported, enabling compatibility with various driving requirements by the host system. The module includes all necessary timing controllers on-board, reducing host BOM component counts.

Applications

The NL8060AC21-21D is suited for industrial human-machine interface terminals, medical diagnostic equipment, test and measurement instruments, transportation control systems (rail, marine, vehicle), and kiosk displays requiring high reliability. The combination of wide temperature range, LED backlight with extended lifetime, and SVGA resolution makes it a reliable choice for applications demanding continuous operation in challenging environments.

Conclusion

The NLTECH NL8060AC21-21D 8.4 inch LCD display module delivers industrial-grade performance with SVGA resolution, LED backlighting, and wide temperature tolerance. Its LVDS interface, robust construction, and long backlight life make it suitable for embedded display applications requiring reliable operation under demanding conditions.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual