The CML40.2-SP-330-NA-NNNN-NW, part number R911170255, is a compact control unit within the Rexroth IndraControl L40 series. It is a DIN-rail mounted PLC-based controller that integrates logic control and motion communication in a single housing, targeting machine automation applications where cabinet space is limited but coordinated drive control is required. The L40 occupies a position between the entry-level L25 and the higher-performance L45 within the IndraControl controller lineup, offering a distinct balance of processing capacity, communication interfaces, and physical footprint.
The controller uses an AMD Geode LX800 processor running at 500 MHz. This x86-compatible architecture provides the computational foundation for the controller’s PLC runtime and motion communication tasks. The working memory includes 64 MB of DRAM and 128 KB of NVRAM. The NVRAM retains critical data across power cycles, such as retentive variables and configuration parameters, without requiring a battery-backed SRAM. The processor and memory configuration are sized for the L40’s intended scope: logic programs of moderate complexity, motion coordination over SERCOS II, and communication handling across multiple fieldbus channels.
The L40 controller runs the IndraLogic PLC runtime, which provides the programming environment for machine logic, sequence control, and integration with motion functions. The runtime supports the standard PLC programming languages and manages the cyclic execution of the user program, the updating of I/O, and the communication with drives and higher-level systems.
The “SP” segment in the type code identifies the communication configuration of this L40 variant. The controller includes a SERCOS II master interface for motion communication. SERCOS II is a deterministic real-time bus used for connecting drives and motion devices, and the L40’s SERCOS II master capability allows it to coordinate servo axes within the IndraDrive or compatible drive families. The controller also provides a PROFIBUS master-slave interface, enabling integration with PROFIBUS-DP networks at both the master and slave levels. This dual capability allows the L40 to serve as a segment controller that exchanges data with higher-level PROFIBUS masters while also managing its own PROFIBUS slave devices.
An Ethernet TCP/IP interface is included for programming, diagnostics, and vertical communication with supervisory systems. A serial RS-232 interface provides a local connection for configuration or legacy devices. The combination of SERCOS II, PROFIBUS, and Ethernet gives the L40 three distinct communication paths: a deterministic motion bus, a general-purpose fieldbus, and an Ethernet network for engineering and data exchange. The controller’s local I/O includes eight digital inputs and eight digital outputs, electrically isolated, with the digital inputs supporting interrupt capability.
The controller operates from a nominal 24 VDC supply and complies with DIN EN 61131-2. The voltage tolerance is -15 percent to +20 percent, accommodating the variations typical of industrial 24 VDC power systems. The maximum current consumption is 2.6 A for the ULS supply and 8 A for the UM and US supplies. The housing dimensions are 75.9 mm in depth, 120 mm in height, and 175.4 mm in length, defining a compact DIN-rail footprint that leaves cabinet space for other devices. A 5 by 10 dot matrix LCD display and LED status indicators provide local visibility of controller state, and the reset button is recessed so that it can only be actuated with a tool, preventing accidental resets.
The controller carries CSA C22.2 No. 142-M1987 and UL508 certifications, reflecting compliance with North American industrial control equipment standards. The DIN-rail mounting and the compact housing align the L40 with the physical conventions of modular control cabinets, where devices are arranged along standardized rails and wired through front-facing terminals.
The CML40.2-SP-330-NA-NNNN-NW is intended for machine automation applications that require a PLC with integrated motion communication, moderate local I/O, and multiple fieldbus options in a DIN-rail format. Its SERCOS II master interface allows it to coordinate drives directly, while the PROFIBUS interface supports integration into plant networks where PROFIBUS is the established fieldbus. The Ethernet and serial ports provide the engineering and diagnostic access expected of a modern controller. The L40’s 64 MB DRAM and 500 MHz processor support control programs that exceed the capacity of the entry-level L25 but do not require the higher memory and performance of the L45 or L65. The result is a controller positioned for compact machines and subsystems where logic control, motion coordination, and network integration converge in a single DIN-rail device.