Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

来源: | 作者:FAN | 发布时间 :2025-04-17 | 611 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

IMPORTANT INFORMATION AND SAFETY WARNINGS: Solid-state equipment has different characteristics than electromechanical equipment and should be used to ensure that the application is acceptable and Rockwell is not responsible for consequential damages. Safety risks are identified in the documentation by various symbols, such as warnings of explosion, electric shock, burns, and other hazards.


Hazardous area approvals: Zone 2 certified products in Europe have restrictions on their use and require specific enclosures with specific levels of protection, etc.; when used in North American Class I Division 2 environments, the temperature code for the combined system has requirements that require attention to the risk of explosion prevention during operation.


Environment and housing requirements: for pollution level 2, overvoltage category II, altitude of 2000 metres below the industrial environment, need to be installed in a suitable shell, the shell should be flame-retardant and so on.

Static electricity protection: the equipment is sensitive to static electricity, the operation needs to touch the grounded object, wear a grounded wrist strap and other anti-static measures.


Module type and control: 1756-CN2 for non-redundant media, 1756-CN2R for redundant media, also available for independent control. For redundant control, pairs of modules need to be set to the same network address and installed in the corresponding slot.

Pre-installation preparation: Understand how to handle the module, prepare power supply, module, chassis, taps, USB cable and other components.

Module installation steps: set the network address (independent modules need to be unique), can reset the module to the factory settings. Before installation, prepare the chassis and power supply, determine the mounting slot, insert the module and ensure a good connection.


Network connection: Connect the module to the network with the specified taps, redundant media and non-redundant media are connected in different ways, pay attention to the risk of electric shock and explosion when connecting, and check the status of the module after connection.

Module Removal: Press the upper and lower tabs to slide out the module; when replacing the module, pay attention to keep the address and slot unchanged.

Software Setup: Installation EDS file can be uploaded from the module or downloaded from the website. Configure RSLinx software to use USB port, after installing USB driver, you can carry out programming and other operations through USB connection, pay attention to the length of USB cable and the use of environmental requirements.


Caution

Network Address Setting: The same ControlNet network address must be selected for each pair of redundantly controlled modules (i.e. master and slave). This is because in a redundant system, pairs of modules need to communicate and work together via the same network address. If the addresses are different, the system will not recognise them as a pair of redundant modules, and thus redundant control functions cannot be achieved. In practice, when using a small screwdriver to set the network address switch of the module, make sure that the address of the master and slave modules is the same, such as set to the same address between 01 - 99. Address 00 is an invalid address and cannot be used.


Slot arrangement: Pairs of redundant modules should be placed in the same corresponding slots in their respective redundant control chassis pairs. In the case of a ControlLogix redundant system, for example, modules performing the same function in the master and slave chassis should be installed in the same numbered slots. This arrangement helps the system quickly identify and switch between the master and slave modules, and ensures that when the master module fails, the slave module can take over in time to maintain normal system operation. When determining the location of the module slots, it should be clear that Slot 0 is the first slot and is located on the far left side of the rack, to the right of the power supply, and that pairs of modules should be installed in the corresponding slots with the same number.


Correct connection: When using redundant media, the connection of pairs of modules should be carried out in strict accordance with the specifications. Specifically, connect the channels of the master and redundant slave modules to the same network segment, i.e., from trunkline A to channel A of the 1756-CN2R module and from trunkline B to channel B of the 1756-CN2R module. During the connection process, carefully check the labelling on the tap drop cable to avoid incorrect connections. Incorrect connections will result in incorrect display of the module status, affecting the normal operation of the system and making troubleshooting more difficult.


Specifications

Basic Parameters

Connectors: The 1756-CN2 has one ControlNet BNC connector and the 1756-CN2R has two ControlNet BNC connectors, both of which are equipped with USB 1.1 USB Device USB Series B type sockets.

Communication rate: ControlNet communication rate is 5MB.

Weight: The 1756-CN2 is approximately 0.260kg (0.57lb) and the 1756-CN2R is approximately 0.293kg (0.64lb).

Temperature code: North American temperature code is T4A, IEC temperature code is T4.


Performance Parameters

Nodes and Connections: Maximum number of nodes is 99, supports a maximum of 131 connections, but 3 of these are reserved for redundant control, standard use has 128 connections.

Power Related: 1756 - CN2 max power dissipation 5.6W, thermal dissipation 19.1 BTU/hr, backplane current 1.1A @ 5.1V dc, 3mA @ 24V dc; 1756 - CN2R max power dissipation 6.6W, thermal dissipation 22.5 BTU/hr, backplane current 1.3A @ 5.1V dc, 3mA @ 24V dc.

Isolation Voltage: Isolation voltage 30V (continuous), basic insulation type, ControlNet network to system test voltage 500V ac for 60s.

Wiring Class: Wiring class 2 - on communication ports.


Environmental parameters

Temperature range: Operating temperature 0...60°C (32...140°F), storage temperature - 40...85°C (- 40...185°F).

Humidity: 5...95% relative humidity non-condensing.

Vibration and shock: Vibration 2g @ 10...500Hz, operating shock 30g, non-operating shock 50g.

Certifications: The products have passed various certifications, such as UL, cULus, CSA, FM, CE, EEx, CI, etc., to meet the safety and quality standards of different regions and industries.

Allen Bradley PLC 1756-CN2 1756-CN2R 1756-CN2RXT ControlLogix Temp ...

  • Wavecrest DTS-2079 High-Performance Controller Module
  • Wurth Elektronik 74271132 WE-STAR-TEC Snap Ferrite
  • Woodward 9907-165 Digital Turbine Control Module
  • DS1230Y-150+ 256Kb Non-Volatile SRAM Maxim Integrated
  • ZIPPE MWS10/A Industrial Weighing Transmitter Module
  • ZNYX ZX370 Series Fast Ethernet PCI Adapter
  • Vortran KDL-1230 Precision Medical Control
  • VWR Scientific Model 3000 Lab Equipment
  • Wagner+Grimm CH-6102 ETUI1500 Transformer Technical Specs
  • Wago MCS 231-302/037-000 Male Connector
  • Wago VDE0611 Series Rail-Mounted Terminal Blocks
  • Warner Electric ERS-198 1005-05-001 Electrically Released Brake
  • Yaskawa SGDH-01AE Sigma II Servo Driver
  • Omron 3G3HV-A4022-CE Inverter
  • Omron NT625C-ST152 Color Touch HMI
  • Parker Parvex NX310EAKR7001 NX Series Servo Motor
  • UniOp TCP10G-04-0245 Industrial HMI
  • Yaskawa SGDH-04AE Servo Driver 200V 400W
  • Presstech 7612-099Z-01 PLC Control Board
  • Yaskawa SGDH-10DE Servo Driver 400V 1kW
  • Landis Gyr PCA1 M35M4 CPU Controller
  • MICREX-F FLT-ASFKA PLC Loader with RS232 Cable
  • ABB Bailey INNIS21 Network Interface Module
  • Omron Sysmac CV500-SNT31 SYSMAC LINK Unit
  • Parker Hannifin HID2CS/S4 HiDrive Servo Driver
  • Pogliano Busmar PPeF 224541Z0HAC 250A Switch
  • GE Fanuc A16B-3300-003 Series 16-i Main Board
  • BLQ63M30 Brushless Servo Motor High Precision Motion Control
  • YASKAWA SGDH-08AE-S-OY Servopack Servo Drive Motion Control
  • OMRON C200H-RT201 Remote I/O Unit PLC Communication Module
  • PARKER HPD2S2N Servo Driver Industrial Motion Controller
  • SIEMENS 6AV3617-1JC00-0AX1 HMI Operator Panel Interface
  • KEB E3.SM.001.4400 Servomotor
  • Omron SCY-M1-PRO-51C SYSMAC Programming Console
  • ABB SACE TMAX T4 S 160 4 Pole Circuit Breaker
  • Omron CS1G-CPU44-EV1 PLC CPU Unit
  • ABB SACE PR212/P Electronic Trip Unit
  • Mitsubishi HC-SFS524K AC Servo Motor
  • Parker S.B.C. HPD2S1N Electronics Servo Driver
  • Yaskawa SGMPH-08A1A41 Sigma II Servo Motor
  • Omron FQ2-S25050F Smart Camera Vision System
  • Omron C120-LK202-EV1 Host Link Unit RS-422C Interface
  • 23.SM.000.3400 PLC KEB Servo Motor Industrial Control System
  • Biesse Rover CNI PLC 2153 030 7146.30 Industrial Control Unit
  • OMRON ME5614C Industrial Modem 56000bps V.90 Communication
  • SCHNEIDER BCH16HF07332A5C2 Servo Motor High Precision Control
  • ANFX-P130F-1GL3-33 Precision Gearbox Industrial Transmission
  • Beckhoff CX5020-0110 Embedded PC PLC
  • Schneider PowerLogic P5U20 Protection Relay Easergy
  • Siemens 6ES5 466-3LA11 Simatic Analog Input Module
  • Tex Computer TEB0055 77037 Industrial Terminal
  • Audiotel Engineering 0802P1I8000E Industrial Interface Module
  • ELAU DB-5 Distribution HW 5104 Servo System
  • Touchstar 10K TS10KCC0CEMP Industrial Touch Panel
  • Beckhoff CX2030-0125 Embedded PC PLC
  • Parker Hannifin HID5CS/S4 HIDRIVE 5A Servo Drive
  • Yaskawa ACE-P300-TH5 Servo Drive with Profibus
  • Omron Sysmac SCY-P0 13E Sequencer Controller
  • Saia Burgess PCD4.M120 PCD4.M12 Central Controller
  • Schneider Electric TSX3722101 Modicon Micro PLC
  • Siemens Micromaster 440 6SE6440-2AD25-5CA1 Inverter
  • SICK DL50-P1123 Distance Sensor
  • Yaskawa SGDH-04AE-OY Servo Driver 200V 400W
  • Cincinnati Milacron 3-542-1203A Circuit Board Module
  • Allen-Bradley 1756-EN2T EtherNet/IP Communication Module
  • OMRON CS1H-CPU66-V1 Programmable Logic Controller
  • ABB SACE TMAX S6N 630 Molded Case Circuit Breaker
  • Weidmuller IE-SW-VL16-16TX 16-Port Ethernet Switch
  • Schneider PowerLogic CM4250 Circuit Monitor
  • Sacmi IDPM IDMP1.A SMC 085.16.982 Control
  • Omron C120-LK202-EV1 Host Link Unit
  • Omron FQ2-S15050F Smart Camera Vision System
  • OMRON CJ1G-CPU44H Programmable Logic Controller
  • SIEMENS KTP600 HMI 6AV6 647-0AD11-3AX0 Touch Panel
  • OMRON CS1G-CPU45H EV1 Programmable Logic Controller
  • Omron C200HG PLC System C200H-ID212 C200H-OC226
  • ROBOSYSTEM IOG4AX-HD-100 IOG-HD Motion Controller
  • Datalogic SG4-S3-080-PP-W Safety Light Curtain
  • Omron NS12-TS01B-V2 Interactive Display
  • Esto Electronic E.CGT-405-42TE PLC Rack
  • Siemens 7ED62 Static Three Phase Counter
  • Oemer QCAVS 100 LBE AC Square Frame Servo Motor
  • Schneider Electric TM262M25MESS8T Motion Controller
  • Eaton Moeller MFD-CP8-ME Power Supply
  • Pro-face PL-5700T1-24VDC Industrial Panel PC
  • GE Fanuc IC693APU300J High Speed Counter
  • Fuji Electric Micrex-F FPU080S PLC Module
  • Automation Direct GS2-45P0 AC Drive
  • Omron 3G3MV-C4015 V1000 Inverter
  • Vacon NXI01055A2T0CSS Industrial Inverter
  • Saia Burgess PCD4.M240 Central Controller Module
  • Yaskawa SGDH-10DE Sigma II Servo Drive
  • Stober EK501USOM140 Servo Motor and Drive
  • SCE M68-2000/4 CNC Controller and I/O Board
  • Omron SP10-PR001-V1 PLC Programming Console Specs
  • VACON NXI01055A2T0CSSA Industrial AC Drive
  • OMRON SYSMAC SCY-P1 Sequencer Controller PLC
  • SEL-2440 DPAC Discrete Programmable Controller
  • BIVIATOR CI3098 CPU Encoder Module Industrial Control Unit
  • Siemens 6FC5371-0AA10-0AA2 SINUMERIK NCU 710.2
  • KOLLMORGEN SERVOSTAR S70601-NA High Performance Servo Drive
  • OMRON C200HW-PCU01 Fastnet PCMCIA LAN Communication Unit
  • ibaFOB-2io-D Two-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-D Four-Channel Fiber Optic Input Output Card
  • ibaFOB-io-S Single-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-S Four-Channel Fiber Optic Input Output Card
  • ibaFOB-4o Four-Channel Fiber Optic Output Interface Card
  • ibaFOB-4i-S Enhanced Four-Channel Fiber Optic Input Card
  • ibaFOB-4i Four-Channel Fiber Optic Input Interface Card
  • ibaFOB-io Fiber Optic Interface Card for iba Systems
  • SM128V VMEbus Interface Card for Industrial Data Acquisition
  • ibaLink-SM-128V-i-2o VMEbus Fiber Optic Interface Board
  • GE Fanuc IC693MDL632 125V DC Input Module 8 Points
  • GE Fanuc IC693MDL241 24V AC/VDC Input Module 16 Points
  • GE Fanuc IC693MDL240 120V AC Input Module 16 Points
  • GE Fanuc IC693MDL231 240V AC Isolated Input Module
  • GE Fanuc IC693MDL230 120V AC Isolated Input Module
  • GE Fanuc IC693MDL654 5/12 VDC 32-Point Input Module
  • GE Fanuc IC693MDL653 24 VDC 32-Point Input Module
  • GE Fanuc IC693MDL648 48 VDC 16-Point Input Module
  • GE Fanuc IC693MDL646 24 VDC 16-Point Input Module
  • GE Fanuc IC693MDL634 24 VDC Input Module 8 Points
  • GE IM 3100 D 1007722 Control Module
  • GE IM0146B Industrial Circuit Board
  • GE IM0059E0-10070 Interface Board
  • GE IM0094C Industrial Control Board
  • GE IC200PNS002-AB VersaMax PROFINET Scanner
  • GE F650BFBF1G0HI Feeder Protection Relay