Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

来源: | 作者:FAN | 发布时间 :2025-04-17 | 469 次浏览: | Share:

AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

IMPORTANT INFORMATION AND SAFETY WARNINGS: Solid-state equipment has different characteristics than electromechanical equipment and should be used to ensure that the application is acceptable and Rockwell is not responsible for consequential damages. Safety risks are identified in the documentation by various symbols, such as warnings of explosion, electric shock, burns, and other hazards.


Hazardous area approvals: Zone 2 certified products in Europe have restrictions on their use and require specific enclosures with specific levels of protection, etc.; when used in North American Class I Division 2 environments, the temperature code for the combined system has requirements that require attention to the risk of explosion prevention during operation.


Environment and housing requirements: for pollution level 2, overvoltage category II, altitude of 2000 metres below the industrial environment, need to be installed in a suitable shell, the shell should be flame-retardant and so on.

Static electricity protection: the equipment is sensitive to static electricity, the operation needs to touch the grounded object, wear a grounded wrist strap and other anti-static measures.


Module type and control: 1756-CN2 for non-redundant media, 1756-CN2R for redundant media, also available for independent control. For redundant control, pairs of modules need to be set to the same network address and installed in the corresponding slot.

Pre-installation preparation: Understand how to handle the module, prepare power supply, module, chassis, taps, USB cable and other components.

Module installation steps: set the network address (independent modules need to be unique), can reset the module to the factory settings. Before installation, prepare the chassis and power supply, determine the mounting slot, insert the module and ensure a good connection.


Network connection: Connect the module to the network with the specified taps, redundant media and non-redundant media are connected in different ways, pay attention to the risk of electric shock and explosion when connecting, and check the status of the module after connection.

Module Removal: Press the upper and lower tabs to slide out the module; when replacing the module, pay attention to keep the address and slot unchanged.

Software Setup: Installation EDS file can be uploaded from the module or downloaded from the website. Configure RSLinx software to use USB port, after installing USB driver, you can carry out programming and other operations through USB connection, pay attention to the length of USB cable and the use of environmental requirements.


Caution

Network Address Setting: The same ControlNet network address must be selected for each pair of redundantly controlled modules (i.e. master and slave). This is because in a redundant system, pairs of modules need to communicate and work together via the same network address. If the addresses are different, the system will not recognise them as a pair of redundant modules, and thus redundant control functions cannot be achieved. In practice, when using a small screwdriver to set the network address switch of the module, make sure that the address of the master and slave modules is the same, such as set to the same address between 01 - 99. Address 00 is an invalid address and cannot be used.


Slot arrangement: Pairs of redundant modules should be placed in the same corresponding slots in their respective redundant control chassis pairs. In the case of a ControlLogix redundant system, for example, modules performing the same function in the master and slave chassis should be installed in the same numbered slots. This arrangement helps the system quickly identify and switch between the master and slave modules, and ensures that when the master module fails, the slave module can take over in time to maintain normal system operation. When determining the location of the module slots, it should be clear that Slot 0 is the first slot and is located on the far left side of the rack, to the right of the power supply, and that pairs of modules should be installed in the corresponding slots with the same number.


Correct connection: When using redundant media, the connection of pairs of modules should be carried out in strict accordance with the specifications. Specifically, connect the channels of the master and redundant slave modules to the same network segment, i.e., from trunkline A to channel A of the 1756-CN2R module and from trunkline B to channel B of the 1756-CN2R module. During the connection process, carefully check the labelling on the tap drop cable to avoid incorrect connections. Incorrect connections will result in incorrect display of the module status, affecting the normal operation of the system and making troubleshooting more difficult.


Specifications

Basic Parameters

Connectors: The 1756-CN2 has one ControlNet BNC connector and the 1756-CN2R has two ControlNet BNC connectors, both of which are equipped with USB 1.1 USB Device USB Series B type sockets.

Communication rate: ControlNet communication rate is 5MB.

Weight: The 1756-CN2 is approximately 0.260kg (0.57lb) and the 1756-CN2R is approximately 0.293kg (0.64lb).

Temperature code: North American temperature code is T4A, IEC temperature code is T4.


Performance Parameters

Nodes and Connections: Maximum number of nodes is 99, supports a maximum of 131 connections, but 3 of these are reserved for redundant control, standard use has 128 connections.

Power Related: 1756 - CN2 max power dissipation 5.6W, thermal dissipation 19.1 BTU/hr, backplane current 1.1A @ 5.1V dc, 3mA @ 24V dc; 1756 - CN2R max power dissipation 6.6W, thermal dissipation 22.5 BTU/hr, backplane current 1.3A @ 5.1V dc, 3mA @ 24V dc.

Isolation Voltage: Isolation voltage 30V (continuous), basic insulation type, ControlNet network to system test voltage 500V ac for 60s.

Wiring Class: Wiring class 2 - on communication ports.


Environmental parameters

Temperature range: Operating temperature 0...60°C (32...140°F), storage temperature - 40...85°C (- 40...185°F).

Humidity: 5...95% relative humidity non-condensing.

Vibration and shock: Vibration 2g @ 10...500Hz, operating shock 30g, non-operating shock 50g.

Certifications: The products have passed various certifications, such as UL, cULus, CSA, FM, CE, EEx, CI, etc., to meet the safety and quality standards of different regions and industries.

Allen Bradley PLC 1756-CN2 1756-CN2R 1756-CN2RXT ControlLogix Temp ...

  • ABB P8151B communication interface module
  • ABB P8403C controller module
  • ABB P8431 controller module
  • ABB Y129740-002 Analog Module
  • ABB PFTL201D 100KN 3BSE008922R0100 Tension Sensor
  • ABB PPD117A3011 3BHE030410R3011 Excitation Controller
  • ABB PPD512A10-454000 3BHE040375R103E Static Excitation System Unit Module
  • ABB 3BHE046836R0101 GFD563A101 Interface Module
  • ABB 3BHE023784R2530 PPD113B01-25-111000 Controller Module
  • ABB PFCL201CE 50KN 3BSX802939-108 Tension Controller
  • ABB LS4000 diode laser analyzer
  • ABB REM615 HBMBCCAHNB1NN1XD Motor Protection Control
  • ABB 3BHE017628R0002 PPD115A02 SG579989013 Controller Module
  • ABB G2000A5.7ST human-machine interface
  • ABB DKTFM418B 3BHB015651P0001 Controller
  • ABB 3BHE039724R0C3D PPD513 A0C-100440 AC800PEC Controller
  • ABB PPD513AOC -100440 3BHE039724R0C3D 800 D513 Integrated Gate Commutator Transistor (IGCT)
  • ABB XUD194 XUD194A 3BHC018137R0001 Controller Unit Module
  • ABB UDC920BE01 3BHE034863R0001 High Voltage Inverter
  • ABB PPD517A3011 3BHE041576R3011 Excitation Controller
  • ABB MT-91-ARC FP A Control Panel
  • ABB UAC383AE01 HIEE3008900001 interface module
  • ABB XVC722AE101 3BHB002751R0101 High Performance Industrial Control Module
  • ABB TB820V2 3BSE013208R1 Modulebus Cluster Modem
  • ABB 3BHE003604R0102 UFC765AE102 circuit board
  • ABB SPSED01 High-Performance SOE DI Module
  • ABB GFD233A103 3BHE02294R0103 multifunctional control machine
  • ABB DO810 3BSE008510R1 Digital Output Module
  • ABB PM866A 3BSE076359R1 Process Controller
  • GE P111-6053 Advanced Microcontroller
  • GE SPU232.1-CAN PART NO: 029.354 630. Industrial grade module
  • ALSTOM VCM 232.2 029.359 088 VME-MANAGER-MASTER 0085.022.99
  • ALSTOM Centrol Unit COP 232.2 029.232 446
  • ABB PPD539A102 3BHE039770R0102 Control System Module
  • ABB UFC921A101 3BHE024855R0101 Digital Control Module
  • ABB UFC911B106 3BHE037864R0106 Voltage Measurement Board
  • ABB 5SHY4045L0006 3BHB030310R0001 IGCT module
  • ABB HIEE300024R4 UAA326A04 control module
  • ABB PPC905AE101 3BHE014070R010 Controller Module
  • ABB CDP-312R CONTROL PANEL
  • ABB TPPB-02 Control Processor Module
  • ABB UFC762AE101 3BHE006412R0101 motor control interface
  • ABB 1TGE120020R0614 industrial control module
  • ABB UFC760BE145 3BHE004573R0145 High-Voltage Interface Board
  • ABB XVC768116 3BHB007211R116 Programmable Controller
  • ABB XVC767AE105 3BHB007209R0105 Current Monitoring Board
  • ABB PCS6000 VLM70 3BHE034262R0001 Medium-Voltage Converter Module
  • ABB FPX86-9364-A controller motherboard
  • ABB FPX86-9345-B 3BHL000986P0006 Controller Module
  • ABB S-053M 3BHB012897R0003 Phase controller module
  • ABB 3BHE05077R0102 UNS0881b-PV2 control board
  • ABB VIPA972-0DP01 bus connector
  • ABB HS810 3BDH000305R0101 Controller Module
  • ABB PF900-NR 3BDH000357 power module
  • ABB 3BHB005245R0101 power board
  • ABB SUE3000 1VCR007346 G0032 Synchronous Motor Exciter
  • ABB SUE3000 1VCR007346 G0028 High speed Transmission Equipment
  • ABB UFC921A 3BHE024856P106 Communication Module
  • ABB GMKP2800-32IBY Communication Module
  • ABB PS203PRESSPMPPS Intelligent Control Module
  • ABB UNS4681V511 3BHE004074R0511 Expansion Unit Module
  • ABB PFTL101B 10KN 3BSE004197R1 high-performance weighing sensor
  • ABB CI532V02 3BSE003B27R1 Communication Module
  • ABB COM0034 control module
  • ABB 216VC626/P1000 HESG324442R112 processor unit relay card
  • ABB 216MB66 HESG324510M1 PLC Memory Expansion Module
  • ABB SPAJ140C overcurrent and ground fault relay
  • ABB DI840 3BSE020836R1 Digital Input Module
  • ABB AI845 3BSE023675R1 Analog Input Module
  • ABB B5LA HENF327886R0001 DC power module
  • ABB P7LA HNEF105323R0002 High Performance Control Module
  • ABB PPC322AEV01 HIEE300697R1 excitation control board
  • ABB REF620C_F NCFNAAAAABC2DNN1XF Feeder Protection and Control
  • ABB P72140-4-0788740 CTI21-P Input/Output Module
  • ABB DYTP123A 61430001-TW Ethernet Connection Module
  • ABB DYSF118B 61430001-XG Communication Interface Module
  • ABB DYPS154C 61430001-YP Serial Communication Module
  • ABB DTCC901B 61430001-FU Ethernet Communication Module
  • ABB SB510 3BSE000861R1 Backup Power Supply 110/230V AC
  • ABB CI535V26 3BSE022161R1 Communication Interface Module
  • ABB RAO02 redundant analog output module
  • ABB RAI02J redundant analog input module
  • ABB 1MRK002133-ABr02 analog-to-digital module
  • ABB UNITRAL1010 3BHE035301R0004 voltage regulator
  • ABB 3BHB019265R0410 Analog Input/Output (I/O) Module
  • ABB UNC4672AV1 HIEE205012R1 multi-functional input/output analog module
  • ABB REC650 1MRK008514-CB multifunctional circuit breaker
  • ABB RER 103 bus connection module
  • ABB REF545KB133AAAA High Performance Protection Relay
  • ABB REC670 1MRK002814-AC High-Performance Relay Module
  • ABB DASD001 3ASC25H241 Industrial Digital Input Module
  • ABB RED670 touchpad film
  • ABB NTAC-02 fiber optic cable
  • ABB XVC768AE102 3BHB007211R0102 Analog Input Module
  • ABB AD02 multi-channel integrated I/O module
  • ABB TU842 3BSE020850R1 module terminal unit
  • ABB APBU-44C 64669982 High Performance Controller Module
  • ABB REM611 panel
  • ABB RED615 panel
  • ABB L003748-AR 3BSX108237R300 Voltage Regulating Control Module
  • ABB COM0034 2RCA023019A0004C control module
  • ABB REU615E-D HBUAEAADNCA1BNN1XD Voltage Protection and Control Relay
  • ABB S-113H 3BHB01808R0003 Hydraulic Control Module
  • ABB REU615 panel
  • ABB TB840A 3BSE037760R1 modular cluster modem
  • ABB XVC770BE102 3BHE02103R0102 Controller Module
  • ABB LTC391AE01 HIEE401782R0001 Interface Module
  • ABB XVC770AE 3BHE006414R0001 fieldbus control system multifunctional module
  • ABB XVC768101 3BHB007211R101 Controller Module
  • ABB PM858-C 3BSE093350R1 Process Control System Module
  • ABB UAC389AE01 HIEE30088R0001 module controller
  • ABB AI02J high-performance I/O module
  • ABB IC698CPE030/IC698CPE020 series battery cover
  • ABB KSD211B 3BHE022455R1101 Input Coupling Unit ICU
  • ABB DSCA190V 57310001-PK Communication Processor
  • ABB GFD563A102 3BHE046836R0102 Analog I/O module
  • ABB XVC768115 3BHB007211R115 Industrial Control Module
  • ABB AI815 3BSE052604R1 I-O Module
  • ABB 5SGY3545L0010 3BHB006485R0001 Controller Module
  • ABB DAPI100 3AST000929R109 Ethernet Communication Interface Module
  • ABB SYN5201A-Z,V277 3BHB006714R0277 Auto single channel Syn
  • ABB KUC755AE117 3BHB005243R0117 System Controller
  • ABB CMA130 3DDE300410 Display Front Panel
  • ABB 07DC92D GJR525220R0101 Digital I/O Module
  • ABB PCD237A101 3BHE028915R0101 excitation control module
  • ABB CI627A 3BSE017457R1 Communication Interface
  • ABB 5SHY4045L0004 3BHB021400R0002 3BHE039203R0101 GVC736CE101 thyristor IGCT
  • ABB SYN5202A Controller Module