AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

F: | Au:FAN | DA:2025-04-17 | 709 Br: | 🔊 点击朗读正文 ❚❚ | Share:

AB 1756-CN2 1756-CN2R ControlLogix ControlNet Interface Module

IMPORTANT INFORMATION AND SAFETY WARNINGS: Solid-state equipment has different characteristics than electromechanical equipment and should be used to ensure that the application is acceptable and Rockwell is not responsible for consequential damages. Safety risks are identified in the documentation by various symbols, such as warnings of explosion, electric shock, burns, and other hazards.


Hazardous area approvals: Zone 2 certified products in Europe have restrictions on their use and require specific enclosures with specific levels of protection, etc.; when used in North American Class I Division 2 environments, the temperature code for the combined system has requirements that require attention to the risk of explosion prevention during operation.


Environment and housing requirements: for pollution level 2, overvoltage category II, altitude of 2000 metres below the industrial environment, need to be installed in a suitable shell, the shell should be flame-retardant and so on.

Static electricity protection: the equipment is sensitive to static electricity, the operation needs to touch the grounded object, wear a grounded wrist strap and other anti-static measures.


Module type and control: 1756-CN2 for non-redundant media, 1756-CN2R for redundant media, also available for independent control. For redundant control, pairs of modules need to be set to the same network address and installed in the corresponding slot.

Pre-installation preparation: Understand how to handle the module, prepare power supply, module, chassis, taps, USB cable and other components.

Module installation steps: set the network address (independent modules need to be unique), can reset the module to the factory settings. Before installation, prepare the chassis and power supply, determine the mounting slot, insert the module and ensure a good connection.


Network connection: Connect the module to the network with the specified taps, redundant media and non-redundant media are connected in different ways, pay attention to the risk of electric shock and explosion when connecting, and check the status of the module after connection.

Module Removal: Press the upper and lower tabs to slide out the module; when replacing the module, pay attention to keep the address and slot unchanged.

Software Setup: Installation EDS file can be uploaded from the module or downloaded from the website. Configure RSLinx software to use USB port, after installing USB driver, you can carry out programming and other operations through USB connection, pay attention to the length of USB cable and the use of environmental requirements.


Caution

Network Address Setting: The same ControlNet network address must be selected for each pair of redundantly controlled modules (i.e. master and slave). This is because in a redundant system, pairs of modules need to communicate and work together via the same network address. If the addresses are different, the system will not recognise them as a pair of redundant modules, and thus redundant control functions cannot be achieved. In practice, when using a small screwdriver to set the network address switch of the module, make sure that the address of the master and slave modules is the same, such as set to the same address between 01 - 99. Address 00 is an invalid address and cannot be used.


Slot arrangement: Pairs of redundant modules should be placed in the same corresponding slots in their respective redundant control chassis pairs. In the case of a ControlLogix redundant system, for example, modules performing the same function in the master and slave chassis should be installed in the same numbered slots. This arrangement helps the system quickly identify and switch between the master and slave modules, and ensures that when the master module fails, the slave module can take over in time to maintain normal system operation. When determining the location of the module slots, it should be clear that Slot 0 is the first slot and is located on the far left side of the rack, to the right of the power supply, and that pairs of modules should be installed in the corresponding slots with the same number.


Correct connection: When using redundant media, the connection of pairs of modules should be carried out in strict accordance with the specifications. Specifically, connect the channels of the master and redundant slave modules to the same network segment, i.e., from trunkline A to channel A of the 1756-CN2R module and from trunkline B to channel B of the 1756-CN2R module. During the connection process, carefully check the labelling on the tap drop cable to avoid incorrect connections. Incorrect connections will result in incorrect display of the module status, affecting the normal operation of the system and making troubleshooting more difficult.


Specifications

Basic Parameters

Connectors: The 1756-CN2 has one ControlNet BNC connector and the 1756-CN2R has two ControlNet BNC connectors, both of which are equipped with USB 1.1 USB Device USB Series B type sockets.

Communication rate: ControlNet communication rate is 5MB.

Weight: The 1756-CN2 is approximately 0.260kg (0.57lb) and the 1756-CN2R is approximately 0.293kg (0.64lb).

Temperature code: North American temperature code is T4A, IEC temperature code is T4.


Performance Parameters

Nodes and Connections: Maximum number of nodes is 99, supports a maximum of 131 connections, but 3 of these are reserved for redundant control, standard use has 128 connections.

Power Related: 1756 - CN2 max power dissipation 5.6W, thermal dissipation 19.1 BTU/hr, backplane current 1.1A @ 5.1V dc, 3mA @ 24V dc; 1756 - CN2R max power dissipation 6.6W, thermal dissipation 22.5 BTU/hr, backplane current 1.3A @ 5.1V dc, 3mA @ 24V dc.

Isolation Voltage: Isolation voltage 30V (continuous), basic insulation type, ControlNet network to system test voltage 500V ac for 60s.

Wiring Class: Wiring class 2 - on communication ports.


Environmental parameters

Temperature range: Operating temperature 0...60°C (32...140°F), storage temperature - 40...85°C (- 40...185°F).

Humidity: 5...95% relative humidity non-condensing.

Vibration and shock: Vibration 2g @ 10...500Hz, operating shock 30g, non-operating shock 50g.

Certifications: The products have passed various certifications, such as UL, cULus, CSA, FM, CE, EEx, CI, etc., to meet the safety and quality standards of different regions and industries.

Allen Bradley PLC 1756-CN2 1756-CN2R 1756-CN2RXT ControlLogix Temp ...

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit