²;Example: When U-original=425V, P-original=22.6kW (6000rpm), and U-new=380V,new².
2. Encoder configuration
According to whether it comes with DRIVE CLiQ interface, the corresponding relationship between encoder type and order number is shown in the following table:
Interface type, encoder type, order number, 9th digit, core parameter
No DRIVE CLiQ, no encoder A-
No DRIVE CLiQ incremental encoder (sin/cos 1Vpp, with C/D signal) M 2048 S/R, 1 reference pulse per revolution
No DRIVE CLiQ absolute encoder (EnDat) E single turn 2048 S/R, multi turn 4096 rpm
Equipped with DRIVE CLiQ incremental encoder (22 bits, with commutation position), D resolution 4194304, built-in 2048 pulses/rev
Equipped with DRIVE CLiQ absolute value encoder (22 bit single turn+12 bit multi turn) F operating range of 4096 revolutions, suitable for high-precision positioning
3. Core options
Option Name Model/Code Function and Applicable Scenarios
Radial shaft sealing ring - DIN 3760 standard, upgraded protection level to IP65, compatible with ZF transmission
Transmission 2K120/2K250 planetary, transmission ratio 1:1/1:4, expanding constant power speed range
Moisture proof heating belt Q04/Q02 220V/100W, works when stopped to avoid winding condensation
Insulated bearing L27 non drive end bearing insulation, preventing damage from frequency conversion stray current
Extend warranty Q80 warranty period from standard to 24 months
Selection and installation specifications
1. Selection tools and processes
Core tool: SIZER software (order number 6SL3070-0AA00-0AG0), supporting steps:
Define driving tasks (such as spindle/feed drive);
Input load parameters (torque, speed, cycle time);
Match motor model (output power/torque curve);
Select the driving components (power module, motor module);
Generate selection report (including component list and dimension diagram);
Auxiliary tools: STARTER (debugging software), SinuCom (fault diagnosis).
2. Installation and operation restrictions
Installation position: Supports horizontal (IM B3) and vertical (IM V1/V3), axial force needs to be recalculated when extending upwards/downwards;
Concentricity requirements: Radial runout tolerance R level (0.025mm for AH100-132, 0.03mm for AH160-225), flange coaxiality tolerance R level (0.05mm for AH100);
Vibration control: vibration speed ≤ 2.8mm/s (level A), vibration level SR should be selected for exceeding the rated speed;
Wiring specifications: Power cables should avoid stretching/damage, DRIVE CLiQ interfaces should be anti-static (ESD protection), and external fan cables should be wired independently.

Email:wang@kongjiangauto.com