Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Environmental protection water treatment

F: | Au:佚名 | DA:2023-11-22 | 562 Br: | 🔊 点击朗读正文 ❚❚ | Share:

What are the reasons for the stability of colloid that can exist in water?

(1) The surface of the colloid is charged;

(2) There is a water level on the surface of the colloid;

(3) The surface of the colloid absorbs some substances that promote the stability of the colloid.

What is the purpose of using coagulants?

1) Improve the structure of the floc, make its particles grow, strong and heavy;

2) Adjust the PH value and alkalinity of the treated water to achieve the best coagulation conditions and improve the coagulation effect; Coagulants themselves do not coagulate, but can promote the coagulation process of impurities in water.

 the basic concept of coagulation?

Because the colloidal particles in the water are negatively charged, they repel each other, and at the same time, they continue to do "brown motion" in the water is extremely stable, not easy to sink, when the right amount of coagulant is added, the tiny colloidal particles in the water can be destabilized, resulting in adsorption bridging, flocculation into flocculent rapidly sinking, this process is called coagulation.

What are the main factors affecting the coagulation effect?

1) PH of water: such as the hydrolysis of PAC to produce Al(OH)3 colloid, when the PH is 6.5-7.5 the smallest dissolution, coagulation effect is good;

2) alkalinity of water: When the alkalinity is insufficient, the coagulant continuously produces H+ in the hydrolysis process, which decreases the PH value and the coagulation effect;

3) Water temperature: when the temperature is low, the viscosity of water is large, the hydrolysis rate is slow, the formation of floc is slow, and the structure is loose, and the particles are small and not easy to precipitate;

4) The composition of impurities in water: the nature and concentration have a great impact on the coagulation effect.

What is the relationship between the form of carbonic acid in water and PH?

1) When PH value ≤4.3, only CO2(free) in water;

2) When PH value =8.3-3.4, more than 98% are HCO3-;

3) When PH >8.4, there is no CO2 in the water

 the purpose of boiler water treatment?

1) Prevent the accumulation of sediment and corrosion of water and steam in the operation of the boiler body and affiliated systems. Improve the heat transfer efficiency of boiler.

2) Ensure steam quality, prevent scaling and corrosion of turbine components, reduce boiler blowdown losses and improve economic benefits under the condition of ensuring water quality

the working principle of centrifugal pump?

Centrifugal pump is the use of impeller rotation to produce centrifugal force water to work, the pump before starting, must pump shell and suction pipe are full of water, and then start the motor, so that the pump shaft drive impeller and water for high-speed rotating motion, water under the action of centrifugal force thrown to the outer edge of the impeller, and collected into the pump shell, through the flow channel of the vortex pump shell into the pressure water pipe.

At the same time, the center of the impeller of the pump forms a vacuum because the water is thrown out, and the water in the suction pool is sucked into the impeller through the suction pipe under the action of atmospheric pressure. The impeller keeps rotating, and the water is constantly thrown out and constantly replenished. This creates a continuous flow of water from the centrifugal pump.

 What is the regeneration of resin?

After softening or desalting, the resin loses the ability to exchange ions. At this time, acid, alkali or salt can be used to reduce and regenerate it to restore its exchange ability, and this process of restoring the ability of the resin is called the regeneration of the resin.

 What are the main factors affecting the resin work exchange capacity?

(1) the quality of water in the influent;

(2) Control index of exchange end point;

(3) the height of resin layer;

(4) Water temperature and flow speed;

(5) The effect of exchanger regeneration and the performance of the resin itself.

What are the chemical properties of resin?

1) Reversibility of ion exchange reactions, such as:

RH+Na+RNa+H+

2) Acid-base:

ROHR+OH-; RHR+H+

3) Selectivity: The adsorption of different ions by ion-exchange resins is not the same.

4) Resin exchange capacity

Positive resin

Fe3+>Al3+>Ca2+>Mg2+>K+≈NH4+>Na+

Negative resin:

SO42->NO3->Cl->HCO3->HSi

What is the pollution of mixed bed resin?

1) Suspended pollution: mostly in the form of Yang resin. Strengthen the pretreatment of raw water.

2) Organic pollution: mainly occurs in strong alkali Yang resin. Main resuscitation methods: Soak the resin in a mixture of NaOH(1-4%) and NaCl(5-12%) for 24 hours.

3) Heavy metal ion iron pollution: mostly formed in negative resin, strengthen the corrosion of pipes and equipment, reduce the Fe content of water, and increase iron removal measures.

 What are the main reasons for the deterioration of RO film performance?

1) Chemical changes of the film itself: hydrolysis of the film, free chlorine, and oxidation interference of active chlorine

2) The physical changes of the film itself: the compaction of the film reduces the water permeability and increases the salt removal rate; Membrane contamination: fouling, microorganisms, solid particles on the surface or inside the membrane.

  • Basler XR2002F Voltage Regulator 9139400101
  • Basler 2D80367G23 DXCB De-Excitation Module 1200V 5000A
  • Basler SR4A-2B15B3A Static Regulator 120V 50/60Hz
  • Basler SSR 125-12NF Static Regulator 9 1859 00 106
  • Basler BE1-BPR Breaker Protection Relay 9272000315
  • Basler SSR 63-12 Static Regulator 9 1859 00 101
  • Basler AEM-2020 Analog Expansion Module
  • Basler BE 25231-001 Transformer BE25231001
  • Basler MVC 108 Manual Voltage Control 9037000102
  • Basler PSS-100-Y5 Power System Stabilizer 0.1-5.0Hz
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SR8A2B10B1A Static Voltage Regulator
  • Basler Electric SSR 125-12 Static Voltage Regulator 9185900102
  • Basler Electric 90-73900-102 Power Supply (Westinghouse 2374A07G03)
  • Basler Electric 9400200117 Control Power Unit 12/24VDC 20W
  • Basler Electric BE1-87G Solid State Generator Differential Relay
  • Basler Electric BE1-32R Style C3ED1TA0S1F Solid State Protective Relay
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric SR8A2B06B3A Static Voltage Regulator
  • Basler MOC3502 90-72300-116 Motor Potentiometer
  • Basler SR4A2310B1A Static Voltage Regulator
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler Electric 90-88800-102 PRS-250 Veri-Sync Relay
  • Basler SR4A-2B05A3E Static Regulator SR4A2B05A3E
  • Basler 9-0723-00-130 9072300130 Control Module
  • Basler BE1-79MA10A6JC0L0F Reclosing Relay
  • Basler CBS-377 Current Boost System 91096001
  • Basler SR4A1B05A3A Static Regulator 480V 62.5V 10VA
  • Basler BE159N A7ED1JC0S0F Protective Relay BE159N-0
  • Basler BE3-25A Auto-Synchronizer S.No. 728
  • Basler BE1-50 Instantaneous Overcurrent Relay G4EA1RG0N0F
  • Basler Electric KT3B Voltage Regulator
  • Basler Electric ACA2500-14GCSYM GigE Camera
  • Basler Electric XR2002F Voltage Regulator
  • Basler Electric BE1-50 Instantaneous Overcurrent Relay F2EA1PA0N5F
  • Basler Electric CBS 212A Current Boost System
  • Basler Electric BE147NE3FE1PC3N3F Negative Sequence Voltage Relay
  • Basler Electric BE1-79MA10A6JC0L0F Automatic Reclosing Relay
  • Basler Electric BE1-59N A6E E1C B0N1F Neutral Overvoltage Relay
  • Basler Electric MVC 108 Manual Voltage Control
  • Basler Electric BE1-59-A4E-E1C-A0N0F Overvoltage Relay
  • Basler BE1-57/27R Solid State Protective Relay
  • Basler BE3-25AX Time Overcurrent Relay
  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System