Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641
    ❤ Add to collection
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥21257.00
      ¥23251.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.570KG
    • Quantity:
    • (Inventory: 43)
Description
<span style="font-size: 18px; font-family: arial;">Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641</span>

Rexroth VT-SWA-1-12/DFEE Angle Sensor

The VT-SWA-1-12/DFEE, part number R900913641, is an angle sensor within the Rexroth hydraulic valve electronics range. It is a position feedback device that measures the rotational angle of a valve spool or a control element and converts this angle into an electrical signal. The sensor is used in closed-loop hydraulic valve control, where the actual spool position must be known in order to regulate the flow or pressure accurately. The VT-SWA series is designed for integration with Rexroth proportional and servo valves and their associated amplifier cards.

Position Feedback Principle

The angle sensor operates on a non-contact measurement principle, converting the rotational displacement of the valve spool into a proportional electrical signal. The sensor element is coupled to the valve spool through a mechanical linkage or a magnetic coupling, depending on the valve design. As the spool rotates or translates, the sensor produces a signal that represents the actual position. This signal is fed back to the valve amplifier, which compares it with the command signal and adjusts the solenoid current to minimize the position error.

The feedback signal is used by the amplifier’s closed-loop control circuit to compensate for the nonlinearity and the friction of the valve. Without position feedback, the valve response would depend on the solenoid characteristics and the hydraulic forces, which vary with pressure and temperature. The angle sensor provides the actual position information that allows the amplifier to maintain the commanded valve position regardless of these influences, improving the accuracy and repeatability of the hydraulic control.

Sensor Characteristics

The VT-SWA-1-12/DFEE is specified for the measurement range, the signal output, and the electrical connection defined by the type code. The sensor is designed to operate with the Rexroth valve amplifier cards that provide the excitation voltage and process the feedback signal. The electrical interface includes the supply connections and the signal output, and the sensor housing provides mechanical protection and mounting provisions for the valve installation.

The sensor’s measurement range and resolution determine the achievable positioning accuracy of the valve. The signal output is proportional to the measured angle, and the amplifier’s feedback circuit is matched to the sensor’s characteristics. The sensor’s temperature behaviour and long-term stability influence the valve’s performance over the operating range, and the sensor is designed to maintain its accuracy under the temperature and vibration conditions of industrial hydraulic systems.

Integration with Valve Amplifiers

The angle sensor is part of the closed-loop control chain that includes the valve amplifier, the valve solenoid, and the valve spool. The amplifier generates the solenoid current, the solenoid moves the spool, the sensor measures the spool position, and the amplifier compares the measured position with the command. The feedback loop is closed through the sensor and the amplifier, and the loop gain and damping are set during commissioning to achieve stable and accurate valve response.

The sensor’s electrical connection is arranged to match the amplifier’s input configuration. The wiring between the sensor and the amplifier must be routed to avoid interference from the solenoid cables and the power cables. The sensor’s signal is low-level, so the wiring practices for low-level signals must be followed to maintain the signal integrity and the measurement accuracy.

Mechanical Installation

The sensor is mounted on the valve body or on the valve actuator, and its measuring element is coupled to the spool or the control element. The mounting arrangement must maintain the alignment between the sensor and the measured element, and it must provide the mechanical support required for the sensor housing. The sensor’s linkage or coupling must be free of backlash, so that the measured position accurately represents the actual spool position.

The installation must consider the access for adjustment and service. The sensor’s zero point and gain may require adjustment during commissioning, and the adjustment elements must be accessible when the valve is installed in the machine. The sensor’s housing and the cable entry must be protected against hydraulic fluid, dust, and mechanical damage.

Application Profile

The Rexroth VT-SWA-1-12/DFEE angle sensor is used in hydraulic systems where proportional or servo valves require position feedback for accurate flow or pressure control. Typical applications include injection molding machines, presses, machine tools, and test stands where the valve position must be regulated with high precision. The sensor’s role is to provide the actual position signal that closes the valve control loop, allowing the amplifier to compensate for valve nonlinearity, friction, and hydraulic force variations. As a member of the VT-SWA series, the sensor follows the product family conventions for measurement principle, signal interface, amplifier compatibility, and valve integration.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide