The DBDS 20 P18/400V is a pressure relief valve within the Rexroth hydraulic valve range. It is a direct-operated safety valve that limits the pressure in a hydraulic system by discharging excess fluid to the tank when the set pressure is reached. The valve protects the hydraulic components from overpressure and is used as a safety element in hydraulic power units, circuits, and individual actuators. The type code identifies the valve series, the nominal diameter, the adjustment range, and the pressure rating of this configuration.
The pressure relief valve operates on a force balance between the hydraulic pressure acting on a closing element and a spring force that holds the element closed. When the system pressure exceeds the set value, the hydraulic force overcomes the spring force and opens the valve, allowing fluid to flow from the pressure side to the tank. The valve closes again when the pressure drops below the set value. The direct-operated design uses a single closing element and a single spring, which provides a simple and reliable pressure limitation function with a defined response to pressure changes.
The P18 segment of the type code defines the adjustment range of the spring and the pressure setting of the valve. The 400V segment indicates the maximum pressure rating of the valve body and the internal components. The size 20 nominal diameter determines the flow capacity of the valve, which is the volume of fluid that can be discharged at a given pressure difference across the valve. The valve is designed to handle the full pump flow of the protected circuit, so that the pressure cannot rise above the set value even when the actuator is stalled.
The pressure relief valve is specified by the set pressure, the cracking pressure, the full-flow pressure, and the permissible flow rate. The cracking pressure is the pressure at which the valve begins to open, and the full-flow pressure is the pressure at which the valve passes the rated flow. The difference between these two values determines the pressure override of the valve, which influences the pressure rise in the system when the valve opens. The valve’s dynamic response affects the pressure peaks that can occur during sudden load changes or actuator stops.
The valve’s internal leakage in the closed position and the flow resistance in the open position determine the hydraulic losses of the circuit. The valve body and the internal components are designed for the pressure rating and the fluid compatibility of the hydraulic system. The adjustment element allows the set pressure to be changed within the spring range, and the adjustment is secured against unauthorized changes after commissioning.
The valve is installed in the hydraulic circuit with the pressure port connected to the protected pressure line and the tank port connected to the return line. The installation position and the port orientation must allow the valve to function correctly and must provide access for adjustment and service. The valve body is mounted on a manifold or a pipe connection, and the mounting arrangement must support the weight of the valve and the connected piping.
The set pressure is adjusted by turning the adjustment screw, which changes the compression of the spring. The pressure is measured at a gauge port or at a pressure sensor in the circuit, and the adjustment is performed with the system at operating temperature to account for the fluid viscosity and the thermal expansion. After adjustment, the setting is locked to maintain the pressure limit during operation.
The Rexroth DBDS 20 P18/400V pressure relief valve is used in hydraulic systems that require reliable pressure limitation. Typical applications include hydraulic power units, presses, injection molding machines, machine tools, and general hydraulic circuits where the system pressure must be limited to protect the components and the piping. The valve’s role is to provide a safety function that prevents overpressure and to define the maximum pressure of the circuit. As a member of the DBDS series, the valve follows the platform conventions for direct-operated relief design, adjustment range, pressure rating, and hydraulic installation.