SIEMENS 3AH3 series vacuum circuit breaker

Core features and structure of the product

1. Core design and maintenance free advantages

Vacuum arc extinguishing system:

The arc extinguishing chamber adopts air insulation, which can be freely contacted and the insulation components are easy to clean in harsh environments;

The upper bracket of the arc extinguishing chamber is fixed, the lower bracket is axially guided, and the supporting components absorb external forces and contact pressure during opening and closing;

Maintenance free cycle: Under normal conditions (IEC 62271-1), it supports 10000 operating cycles without lubrication or adjustment.

Spring energy storage operating mechanism:

Energy storage method: electric energy storage (standard, motor voltage 24-240V DC/AC) or manual energy storage (with dedicated handle, order number 3AX15 30-4A/B/C);

Opening and closing control: remote electric (closing soleoid voltage 24-240V DC/AC), local mechanical/electric (to prevent accidental closing, switch equipment interlock needs to be connected);

Operation sequence: Supports standard sequence O-3min-CO-3min-CO (normal current), CO-30min-CO (short-circuit current), and some models support O-0.3s-CO-15s-CO (≤ 31.5kA).

2. Key functions and safety design

Free release mechanism: in accordance with IEC 62271-100, when receiving a disconnection command during the closing process, the contact immediately returns to the disconnection position and remains in place to avoid continuous disconnection ("pump effect");

Interlocking system:

Electrical interlocking: The auxiliary contacts of the circuit breaker control the electromagnetic lock of the isolation switch, which can only be operated when the circuit breaker is opened;

Mechanical interlocking: detecting the position of the circuit breaker through sensors to prevent on load opening and closing, and adapting to drawer type components;

Release signal control: When the NO contact is opened, it instantly closes, triggering the alarm system. Local control requires a series cut-off switch (distinguishing between automatic/manual opening).


Technical parameters and environmental adaptation

1. Core electrical parameters (classified by voltage level)

Voltage level Rated lightning impulse withstand voltage (kV) Rated short-time power frequency withstand voltage (kV) Rated short-circuit breaking current (kA) Rated normal current (A) Pole distance (mm)

7.2kV 60/75 20/32 50/63 1250-4000 210/275

12kV 75/95 28/36 50/63 1250-4000 210/275

17.5kV 95/110 36/42 50/63/72 3150-8000 275/300

24kV 125/145 50/60 50/63/72 3150-8000 275/300

36kV 170/185/195 70/85/95 31.5/40 1250-4000 350

40.5kV 185/195 85/95 31.5/40 1250-4000 350

2. Environmental and installation restrictions

Climate environment: Complies with IEC 60721-3-3, with specific levels as follows:

Key requirements for environmental type level

Climate environment 3K4 low temperature -5 ℃, humidity ≤ 95%/day, ≤ 90%/month

Biological environment 3B1 is free from mold and insect erosion

Mechanical environment 3M2 anti vibration and impact

Chemical active substance 3C2 is resistant to slightly corrosive gases (without freezing/wind blown precipitation)

Mechanical active substance 3S2 requires regular cleaning of insulation components

Elevation and insulation correction:

When the reference altitude is 1000m, the insulation level needs to be corrected according to the altitude coefficient K a, with the formula: U ≥ U 0 × K a; Example: At 2500m, K a=1.2. If a 75kV lightning impulse withstand voltage is required, a 90kV reference insulation level should be selected.

Current carrying capacity: The reference temperature is 40 ℃ (for open type switchgear), and the rating can be increased when the temperature is below 40 ℃. For example, the carrying current of 6300A can be increased by about 15% at 20 ℃ (refer to the current temperature curve in the document).

image.png

Selection and Configuration Rules

1. Order number structure (16 digits)

Main circuit section (4-8 bits): Define voltage, short-circuit breaking current, rated current, pole spacing, for example:

3AH3 305-6:3 (main group), A (subgroup), H (series), 3 (version), 305-6 (36kV, 40kA, 2500A, 350mm pole spacing);

Secondary equipment section (bits 9-16): Define the combination of release devices, operating voltage, and auxiliary switches, for example:

9-position (release): A (1 shunt release), M (2 shunt releases+1 undervoltage release);

10 positions (closed soleoid): B (24V DC), F (220V DC), K (230V AC);

Option code: End with "- Z" and add a 3-digit code (e.g. Z A20:64 pole plug gold-plated).

2. Core options and auxiliary equipment

Option Category Model/Code Function Description Applicable Scenarios

Automatic tripping device with shunt release (connected to protective relay, 24-240V DC/AC) for overcurrent protection

When the undervoltage release voltage is less than 35% of the rated value, the circuit breaker (24-240V DC/AC) provides abnormal voltage protection

Current transformer operation release without auxiliary power supply, time division switch (0.5/1A rated current), remote and no power supply scenario

Auxiliary switch 6NO+6NC standard, providing regular control requirements for opening and closing status signals

12NO+12NC extended contacts, suitable for complex interlocking multi loop control

Connection interface 24 pole terminal block regular wiring (no plug) fixed installation

64 pole plug for quick insertion and removal, some interfaces can be customized with drawer style switch devices

Additional function Z A30 anti condensation heating (230V AC/50W) for high humidity environment

Z W70 warranty extended to 24 months for critical equipment

Z A70 3AH37 (5000A+) horizontal installation suitable for horizontal installation scenarios

3. Special configuration of generator circuit breaker (IEC/IEEE 62271-37-013)

Additional testing requirements:

Generator side fault: withstand high DC component (130%), no current zero crossing point;

System side fault: higher TRV rise rate, higher test voltage;

Split phase design:

Single pole independent packaging, suitable for 12500A/100kA scenarios, supports parallel operation;

Technical parameter example (17.5kV): Short circuit breaking current 50-90kA, DC component 45-130%, asymmetric breaking current 52-146kA.


Application and maintenance

1. Typical application scenarios

Industrial power distribution: Factory medium voltage power distribution system (high load current 6300A);

Generator protection: 3AH37/38 series (compatible with 17.5/24kV generators, capable of withstanding high DC components);

Special industries: refineries, extruders (harsh environments, compatible with 3C2 grade);

**Retrofit project * *: Replace compressed air generator circuit breakers (6kV, 86.5kA, 3500A).

2. Maintenance and Accessories

Maintenance free range: Within 10000 operating cycles, no lubrication or adjustment is required, only the insulation components need to be cleaned;

Key accessories:

Accessory Name Order Number Usage

Operating handle 3AX15 30-4B manual energy storage

Replacement of vacuum arc extinguishing chamber 3AY17 15-2J 3AH3228-2/6/7 model

Auxiliary switch cable bundle 3AX11 34-2D 64 pole plug wiring (10 wires)

Lubricating grease 3AX11 33-3H Special scenario bearing lubrication (180g Kl ü ber)

Warranty and documentation:

Standard warranty: 12 months, optional Z W70 (24 months), Z W71 (36 months);

Documents: Operating instructions (German/English/French/Spanish), dimension drawings (such as A7E32500008).


Technical data and operational characteristics

1. Operation time (under rated secondary voltage)

Operation type, time parameter value

Closing time from command to contact closure < 75ms

Opening time: 1 shunt release<60ms

2/3 release devices < 55ms

The duration of the arc after the ignition time is opened is less than 15ms

The disconnection time of one shunt release (disconnection+arcing) is less than 75ms

2/3 release devices < 70ms

Energy storage time: Electric energy storage (full capacity) < 15s

2. Release power consumption (reference value)

Release type DC power consumption (W) AC power consumption (VA) Operating range

Closing soleoid 140 140 85-110% rated voltage (DC/AC)

1st shunt release 140 140 70-110% rated voltage (DC), 85-110% (AC)

2nd shunt release 60 60 70-110% rated voltage (DC), 85-110% (AC)

Undervoltage release 20 20 35-0% rated voltage (DC/AC)

Current Transformer Operating Release -10 90-110% Rated Current (AC)

image.png

  • Bently 3500/15 125840-01 Power Supply Module
  • Bently 24765-02-01 Signal Conditioner Module
  • Bently 330130-085-00-00 Extension Cable
  • Bently 3500/22M 138607-01 Vibration Monitor Module
  • Bently 146031-02 Proximity Probe Sensor
  • BENTLY 330104-00-05-10-02-CN Proximity Probe
  • BENTLY 125768-01 3500 I/O Module Interface
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 84152-01 Proximitor Sensor Cable
  • BENTLY 3300/20 Dual Driver Proximitor Housing
  • BENTLY 3300/16-11-01-03-00-00-01 16-Channel Monitor
  • DEIF PPU-3 Power Protection Unit for Genset Control
  • DEIF RMV-112D Reactive Power Divider and Voltage Matching Relay
  • DEIF OPM-1 Output Protection Module for Gensets
  • DEIF IPM-1 Integrated Protection Module for Generators
  • DEIF CM-2 Control Module for Industrial Power Systems
  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor