7.2 Replacing SSD
Turn off the power and disconnect all connections.
Open the right cover plate.
For C6030-0060 and C6030-0070/0080, the SSD slot positions are slightly different (as shown in the instruction manual).
Loosen the fixing screw (Torx TX10), and the SSD will automatically pop up at a tilt angle.
Pull out the old SSD, insert the new SSD (at the same tilt angle), press and tighten the screw (torque 0.5 Nm).
It is recommended to use Beckhoff Service Tool (BST) to backup the operating system image before replacement.
7.3 Fan replacement
Remove the decorative strip (logo strip) on the upper and lower covers of the equipment.
Unscrew a total of 4 Torx TX10 screws from the upper and lower covers.
Pull out the fan casing.
Remove the two Torx screws on the fan mounting plate and unplug the fan power cord (which needs to be threaded through the wire hole).
Install a new fan, reconnect the power cord, and reinstall the casing.
Common troubleshooting
Possible causes and solutions for the fault phenomenon
The device is completely non functional and the power supply is missing. Check the 24V cable and measure whether the terminal voltage is between 22-30V
Unable to fully boot (black screen) BIOS setup error Enter BIOS load defaults
Start but control abnormal software or external device issues Contact the machine or software manufacturer
TwinCAT access error via USB. The default cycle time of 10ms is too short. The TwinCAT cycle time has been increased to 50-80ms
UPS OCT does not work. BIOS does not enable it. Enable UPS OCT Access as Auto as described above
Real time clock reset, motherboard battery depleted, replace CR2032 battery
If the above measures are ineffective, please record the model and serial number (BTN) on the equipment nameplate and contact Beckhoff service( service@beckhoff.com ).
Summary of Technical Specifications
Project specifications
Dimensions (width x height x depth) 132 x 133 x 76 mm (without mounting plate)
Weight approximately 1.46-1.70 kg
Power supply 24 V DC (22-30V), maximum 8A socket
Working temperature 0~55 ℃ (standard), optional 0~70 ℃ (C9900-B950)
Storage/transportation temperature -25~+65 ℃
Maximum humidity of 95%, no condensation
Protection level IP20
Anti vibration (sine) EN 60068-2-6:10-58Hz/0.035mm; 58-500Hz / 0.5G
Impact resistance EN 60068-2-27:5G/30ms
EMC EN 61000-6-2 (Immunity), EN 61000-6-4 (Radiation)
Certified CE, FCC Class A