WOODWARD Turbine Shutdown Trip Block Assemblies

Product Overview

The QuickTrip trip block component is carefully designed for steam, gas, and turbine shutdown systems, suitable for mechanical or generator driven turbines using low-pressure (5-25 bar/73-363 psi) hydraulic trip oil manifolds. Its core function is to quickly discharge the tripping oil main of the turbine, providing a solid guarantee for the safe shutdown of the turbine in emergency situations.

Safety Systems - Sicagen

Model and Features

Represented by the 9907-1978 model, this component has a unique design and notable features.

Fault tolerant design: Three independent rotary valves are used, working together based on a 3-to-2 voting mechanism. This design ensures that in the event of any component failure, such as valve actuators, valves, circuits, or connectors, it will not cause false tripping, greatly improving the reliability of the system and fully complying with the API-670 industry standard. For example, in a complex industrial environment, a valve driver may experience a brief malfunction due to electrical interference, but due to the 3-to-2 voting mechanism, the system can still accurately determine and operate normally without causing unnecessary downtime, ensuring the continuity of production.

Corrosion resistant and self-cleaning design: The components are made of corrosion-resistant materials, with a rotating chip shear force of 25 lbf and a self-cleaning port design. This enables it to operate stably in harsh conditions with dirty or contaminated oil, especially suitable for steam turbine applications. During the operation of steam turbines, their lubricating oil is usually used to drive hydraulic turbine control valve actuators, and the oil system of steam turbines often mixes with dirt, metal shavings, water, and other pollutants such as Babbitt metal, ammonia, etc. In addition, due to the high operating temperature of the steam turbine, the turbine oil is prone to decomposition, producing sludge like substances, resulting in varnishing of internal system components. The 9907-1978 model trip block component, with its special design, can effectively address these issues and ensure the normal operation of the system.

Online maintenance function: This component supports online maintenance. When the turbine is in online operation, users can replace key components such as electrical modules, solenoid valves, circuits, drivers, etc. This feature greatly improves the maintainability of the system and reduces downtime caused by equipment maintenance. For example, during peak production periods, if a certain solenoid valve malfunctions, it can be replaced online without stopping the machine, avoiding the impact of downtime maintenance on production progress.


Technical parameters

Working voltage: 24 VDC, stable low voltage power supply, suitable for various electrical system environments, ensuring the stable operation of component control circuits.

Maximum supply pressure: 500 psi, capable of withstanding high pressure hydraulic oil input, meeting the demand for discharge pressure of the trip oil main pipe under different operating conditions.

Applicable oil types: Mineral oil, synthetic oil, or Fyrquel EHC base oil can be used, with a wide range of oil adaptability and compatibility with different types of turbine oil systems.

Operating temperature range: -40 to+85 ° C (-40 to+185 ° F), can operate normally in extreme environmental temperatures, ensuring stable performance whether in cold outdoor environments or high-temperature industrial plants.

Operating oil temperature range:+15 to+70 ° C (+59 to+158 ° F). There are clear requirements for the oil temperature during operation to ensure that the hydraulic components inside the components can work normally within the appropriate oil temperature range, avoiding the impact of high or low oil temperature on component performance.


Diagnostic testing

Given the adoption of a 3-to-2 configuration, diagnostic testing can be conducted while QuickTrip is online and the turbine is running. The testing program will set the tripping output of the tested module to a tripping state (configured as a power-off state for power-off tripping), and only test one module at a time.

Users can automate the testing process by using the built-in "Automatic Sequence Testing" feature in ProTech TPS, or by leveraging ProTech's programmability and test mode configuration. During the testing process, it is necessary to verify whether there is a running alarm (failure to power on and enter the running state), and to verify the trip time of each module by checking the trip cycle time log. This log will display the last 20 trip events, as well as the time interval from the control signal dropping to the QuickTrip valve rotating to the open position and the trip position sensor sending a trip signal to ProTech. Under normal circumstances, this trip time should be less than 50 ms. If the QuickTrip module (valve) malfunctions upon receiving a command to rotate to open or close, or if the trip time exceeds 50 ms, timely maintenance and troubleshooting are required to ensure the normal operation of the components and the safety of the turbine.


Key advantages

1. High reliability fault-tolerant design

3-for-2 voting mechanism: By working together with three independent rotary valves, any single component failure (such as valve driver, circuit or connector) will not trigger false tripping, meeting the API-670 industry standard and suitable for critical industrial scenarios of continuous operation. For example, when a certain solenoid valve fails due to voltage fluctuations, the other two valves can still maintain normal system logic and avoid unnecessary shutdowns.

Fault isolation capability: Each module operates independently, and the faulty module can be isolated online without affecting the overall system operation, improving the stability of turbine operation.

2. Adaptability to harsh working conditions

Corrosion resistant materials and self-cleaning design: Using corrosion-resistant materials (such as stainless steel valve body), combined with 25 lbf rotating chip shear force and self-cleaning ports, can effectively deal with dirt, metal shavings, and decomposition products (such as Babbitt alloy particles and ammonia pollution commonly found in steam turbines) in the oil, preventing port blockage or valve body corrosion.

Wide temperature operation capability: The operating temperature range is -40 to+85 ° C, suitable for extreme environments (such as outdoor low-temperature or high-temperature factories), and the operating oil temperature range is+15 to+70 ° C, compatible with hydraulic oils of different viscosities.

3. Maintain convenience and efficiency

Online maintenance function: Key components such as electrical modules and solenoid valves can be replaced without stopping the machine, reducing unplanned downtime. For example, during peak production periods, faulty solenoid valves can be directly replaced to avoid production capacity losses caused by maintenance.

Automated diagnostic support: Through the "automatic sequence testing" function of ProTech TPS, module trip time (<50 ms) and operating status can be verified online, potential faults can be detected in advance, and maintenance costs can be reduced.

4. Compliance with safety standards

Multi certification guarantee: Designed to comply with API-670 standards, supporting Canadian/US hazardous site certification and EU ATEX directive, suitable for high-risk industries such as petroleum and chemical, ensuring safety regulatory requirements.

Quick response capability: Trip time ≤ 50 ms, can quickly cut off the power source of the turbine in emergency situations, preventing the expansion of dangerous working conditions such as overspeed and overpressure.


Precautions

1. Installation and environmental requirements

Oil cleanliness control: It is necessary to ensure that the hydraulic oil cleanliness meets the ISO 4406 standard (recommended ≤ 18/16/13) to avoid valve jamming caused by oil contamination. If the oil contains water or particulate matter, it needs to be paired with a high-precision filter (filtration accuracy ≤ 10 μ m).

Temperature limit: The operating oil temperature should be controlled between+15 and+70 ° C. If the oil temperature exceeds 70 ° C, it may lead to increased oxidation of the oil, and a cooling system needs to be configured; When the temperature is below 15 ° C, the viscosity of the oil increases, which may affect the tripping response speed and requires preheating in advance.

2. Maintenance and testing standards

Regular diagnostic testing: Perform a trip time test at least once every quarter, and record the last 20 trip events through ProTech TPS. If a module trips for more than 50 ms, immediately investigate valve wear or hydraulic system leaks.

Precautions for component replacement: When replacing solenoid valves or electrical modules online, the corresponding module power should be disconnected first, and special tools should be used for disassembly to avoid short circuits caused by live operation; After replacement, it is necessary to perform functional verification again.

3. Oil compatibility management

Do not mix oil: Mixing different types of oil (such as mineral oil and synthetic oil) may cause viscosity changes or additive precipitation. It is necessary to ensure that the system uses a single type of oil and regularly test the physical and chemical indicators of the oil (such as acid value and viscosity index).

Fyrquel EHC base oil special treatment: When using this type of oil, attention should be paid to its flame retardant properties, which may affect the sealing material. Fluororubber (FKM) seals should be selected to avoid swelling and failure of ordinary rubber parts.

4. Emergency handling of faults

Troubleshooting of accidental tripping: In case of unexpected tripping, priority should be given to checking the alarm logs of ProTech TPS to confirm whether it is caused by sensor failure or line interference; At the same time, check whether the pressure of the tripped oil main is abnormal (normal working pressure 5-25 bar).

Emergency manual operation: If the automated diagnostic system fails, the trip valve can be forcibly opened by manually operating the knob, but it is necessary to ensure that the operator wears protective equipment to avoid the risk of high-pressure oil spray.

  • Micro Innovation GF1-10TVA-100 Touch Panel
  • Micro Innovation GSO-57EQD-000 Operator Panel
  • Micro Innovation XN-2AI-U Analog Input Module
  • Micro Innovation CAN-4AI/UI Analog Input Module
  • Micro Innovation ZSB-1.5/8-S/S/-/PE Base Terminal
  • Micro Innovation AG XVH-340-57CAN-1-10 HMI Panel
  • Micro Innovation GSO-57EQD-000 Micro Panel
  • Micro Innovation XN-2AI-PT/NI-2/3 Input Module
  • Micro Innovation AG GF0-57SQD-000 Display Panel
  • MICRO INNOVATION AG XN-16DI-24VDC-P Input Module
  • Micro Innovation XN-2AI-PT/NI-2/3 Input Module
  • Micro Innovation MC2-442-57CQB-1-2G Display Panel
  • Micro Innovation XN-16DO-24VDC-0.5A-P Module
  • Micro Design MC200PROFI Programmable Module
  • Micro Innovation XV-252-57MPN-1-10 Micro Panel
  • Micro Innovation CAN-4AI/UI Analog Input Module
  • Micro Innovation GT1-MPI-A000 Panel
  • Micro Innovation MC2-440-10TVB-1-21 Display Panel
  • Micro Innovation XVS-430-57MPI-1-1S 6" HMI
  • Micro Innovation XV-442-57CQB-1-1AB Monitor
  • Micro Innovation ZSB-1.5/8-S/S/-/PE Base Terminal
  • Micro Design 895A Microfiche Reader
  • MICRO INNOVATION XNE-8DI-24VDC-P Input Module 8550100794
  • MICRO INNOVATION MICRO PANEL GF0-10CVD-002
  • Micro Innovation XN-PLC-CANopen Controller 85 50 274124
  • Micro Innovation Display Panel GS0-57E0D-000
  • MICRO INNOVATION CAN-32DI/P2X16 Input Module
  • MICRO INNOVATION XN-2DO-R-NO Relay Output Module
  • MICRO INNOVATION XNE-16DI-24VDC-P Input Module
  • Micro Innovation AG XN-2AI-U Analog Input Module
  • Micro Innovation XN-BR-24DC-D Power Supply
  • Micro Innovation MH2-342-57EIB-1-20 Panel
  • Micro Innovation XV-252-57MPN-1-10 Micro Panel
  • Micro Innovation Display Card EIB2-TP
  • Micro Innovation XV-252-57MPN-1-10 6" HMI
  • Micro Innovation XN-B3T-SBC 16x DO Base Module
  • Micro Innovation XVH-330-57MPI-1-10 Panel
  • Micro Innovation XN-BR-24VDC-D Power Module
  • Micro Innovation EIB2-TP EIB2TP Module
  • Micro Innovation GF0-10CVD-100 Touch Panel
  • MICRO INNOVATION XV-230-57CNN-1-10 HMI-PLC
  • MICRO INNOVATION XN-2DO-R-CO Relay Output Module
  • KMK MICRO INNOVATION GS2-90EMD-000 Micro Panel
  • Micro Innovation XN-2AO-U Analog Output Module
  • Micro Innovation XN-1AO-I Analog Output Module
  • Micro Innovation CAN-32DI/P-2x16 Rack Module
  • Eaton Micro Innovation MC2-440-10TVB-1-11 HMI
  • Micro Innovation AG CAN Bridge 8551224177
  • Micro Innovation XN-2AI-I Analog Input Module Set
  • Micro Innovation XN-4DI-24VDC-P Input Module
  • Micro Innovation Winbloc CAN-16DO/0.5A-PK Module
  • Micro Innovation Micro Panel GFO-10SVD-002 HMI
  • Micro Innovation CAN-24DI/8DO/0.5A-PK Module
  • Micro Innovation DP-24DI/8DO/0.5A-PK I/O Module
  • Weidmuller Micro Innovation CAN-BRIDGE ZSFA 1,5R
  • Micro Innovation CAN-3AI/1AO-UI Profibus Module
  • Micro Innovation PDP-TP Profibus DP Module
  • Micro Innovation CAN-3AI/1AO-UI Analog Module
  • Micro Innovation MC2-430-12TSB-10 HMI Panel
  • Micro Innovation XNE-8DO-24VDC-0.5A-P I/O Module
  • MICRO INNOVATION AG WINBLOC CAN-32DI/P-2x16 85 51 224182
  • MICRO INNOVATION AG WINBLOC CAN-4AO/UI 85 51 224195
  • Micro Innovation Xv-252-57cnn-1-10 HMI Panel
  • Micro Innovation XN Basis XN-S4T-SBBS-CJ 225200
  • Micro Innovation GF1-10TVD-100 Micro Panel
  • Micro Innovation XN-B3T-SBC 16-Fold DO Base Module
  • MICRO INNOVATION AG WINBLOC CAN-3AI/1AO-UI 85 51 224192
  • KMK Micro Innovation GS2-90EMD-000 Micro Panel
  • Micro Innovation MC2-430-10TVB-1-10 PanelView Terminal 24VDC
  • Micro Innovation XNE-8DO-24VDC-0.5A-P I/O Module 8550100795
  • MICRO INNOVATION GF1-10TVB-100 Touch Panel
  • MICRO INNOVATION AG WINBLOC CAN-4AI/UI Analog Input Module
  • MICRO INNOVATION AG WINBLOC CAN-32DO/0.5A-P-2x16 Output Module
  • MICRO INNOVATION AG CAN-32DI/P-2X16 8551224182 Input Module
  • MICRO INNOVATION MK2-230/232-57 Circuit Board 85 28 200000
  • MICRO INNOVATION CAN-BRIDGE 8551224177 CAN Bridge
  • Micro Innovation MC2-430-10TVB-1-10 Panel 24VDC
  • MICRO INNOVATION MC2-432-57CQB-1-10 HMI Panel
  • MICRO INNOVATION AG CAN-BRIDGE 85 51 224177 CAN Bridge
  • MICRO INNOVATION CAN-4AI/UI Analog Input Module
  • MICRO INNOVATION CAN-32DI/P-2X16 Input Module
  • SIGMATEK MDD111 09-404-111 Drive Module
  • SIGMATEK DVI021 Display Interface Module
  • SIGMATEK 00-450-024 C-IPC Processor
  • SIGMATEK MDD-111 MDD111 Drive Module
  • SIGMATEK ICA011 20-102-011 Interface Module
  • SIGMATEK 01-250-010-D NC4Kompakt Control Module
  • SIGMATEK CRIF081 12-751-081 Interface Module
  • SIGMATEK S1026-8AF61-R4E-Z57 Drive Module
  • SIGMATEK 9305.081.02 9227.082.00 Control Module
  • Sigma Tek 5000B-36 Attitude Indicator
  • SIGMATEK CEZ201 12-051-201-O Counter Module
  • SIGMATEK DPS001 Power Supply Module
  • SIGMATEK 994 395 01z Via Interface Module
  • SIGMATEK PC411-K 01-310-411-K Industrial PC
  • SIGMATEK 9816.324.00 Demag NC4 Keyboard
  • SIGMATEK ET261 90010C-71 Operator Terminal
  • SIGMATEK DDI 164 05-006-164 Input Module
  • SIGMATEK CCP 082 C-DIAS Processor Module
  • SIGMATEK CEZ201 12-051-201-O PLC Module
  • SIGMATEK MDD 1111 06178867 Drive Module
  • SIGMATEK S1 073-6AC61-RE-Y08-Z Drive Module
  • SIGMATEK MDD 111 Drive Module MDD111
  • SIGMATEK CSDI161 Safety Module 12-891-161
  • SIGMATEK C-IPC Processor 01-450-024
  • SIGMATEK DIAS DAM122 Analog Mixing Module
  • Sigma Tek 5000B-36 Attitude Gyro Indicator
  • SIGMATEK TMS012 Motherboard Module 05-250-012-T
  • SIGMATEK CCP-531 PLC Module
  • SIGMATEK DIAS DNC4 I/O Module 05-250-011
  • SIGMATEK AI088 Analog Input Module
  • SIGMATEK CEZ201 Counter Module
  • SIGMATEK CIC011 Industrial Computer Module
  • SIGMATEK MDM021 Motor Drive Module
  • SIGMATEK DTO163 Digital Output Module
  • SIGMA-TEK 5000B-36 Attitude Gyro
  • SIGMATEK DM161 Digital Input Module
  • SIGMATEK CCP-531 PLC Control Panel
  • SIGMATEK HZS773 Touch Terminal Operator Panel
  • SIGMATEK MDP101 3 KVA 45-65Hz Driver
  • SIGMATEK ETV1251 Touch Panel 12-230-1251
  • SIGMATEK CIO021 Safety Module 12-013-021
  • Sigma Tek 4000H-5 Directional Gyro
  • SIGMATEK TAE531 I/O Module 01-240-531
  • SIGMATEK DAI081 Input Module 05-009-081
  • SIGMATEK DCP640 Drive Control Module
  • SIGMATEK DCP643 Slides Module A6-29
  • SIGMATEK SCP011 Safety Module 20-890-011