Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB RVT-6 Power Factor Controller RVT6
    ❤ Add to collection
  • ABB RVT-6 Power Factor Controller RVT6

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥34628.00
      ¥39567.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.330KG
    • Quantity:
    • (Inventory: 3534)
Description
<span style="font-size: 18px; font-family: arial;">ABB RVT-6 Power Factor Controller | 6-Step Reactive Power Regulator</span>

ABB RVT-6 Power Factor Controller

The ABB RVT-6 is a microprocessor-based power factor controller designed to optimize electrical efficiency in industrial and commercial power systems. This advanced controller automatically manages reactive power compensation by switching capacitor banks to maintain target power factor values. With its backlit LCD graphical display, intuitive user interface, and comprehensive measurement capabilities, the RVT-6 provides precise control over power factor regulation, reducing energy costs, improving voltage stability, and increasing the effective capacity of electrical distribution systems.

Technical Specifications

SpecificationDetail
Number of Steps6 (standard RVT-6 model)
Measurement Voltage Range50 V to 690 V AC (line-to-line)
Operating Temperature-10°C to +60°C (14°F to 140°F)
Display TypeBacklit LCD graphical display with 6 languages
CommunicationModbus RTU (RS485) on RVT-6 Modbus variant
Current Input5 A or 1 A RMS (selectable)
Auxiliary Supply Voltage100 V to 440 V AC (50/60 Hz)
Power Consumption12 VA
AccuracyClass 0.5 (IEC 61000-4-30)
Protection DegreeIP40 (front panel), IP20 (terminals)

Key Features and Benefits

  • Automatic Power Factor Correction: Continuously monitors cos phi and switches capacitor steps to achieve target PF.

  • 6-Step Control Output: Supports up to 6 capacitor steps for precise reactive power compensation.

  • Comprehensive Measurement: Measures voltage, current, active power, reactive power, frequency and harmonic distortion.

  • Intuitive Operation: Backlit graphical display and multilingual menu simplify setup and monitoring.

  • Advanced Alarms & Data Logging: Records events, alarms and operational statistics for analysis.

  • Modbus Communication: Integrates into SCADA and energy management systems for remote control and monitoring.

Functional Overview

The RVT-6 continuously measures the electrical parameters of the network, including line voltage, load current, and harmonic content. Based on the measured cos phi, the controller decides when to connect or disconnect capacitor steps to bring the power factor to the user-defined setpoint. The unit supports both standard and automatic startup sequences, and features intelligent learning of the capacitor bank response times. The RVT-6 also provides protection against overvoltage, undervoltage, and harmonics, preventing capacitor damage and ensuring system reliability.

Compatibility and Integration

The ABB RVT-6 is compatible with most low voltage capacitor banks and can be integrated into new or existing power factor correction panels. The Modbus variant allows direct connection to building management systems or PLCs for remote monitoring and control. The controller includes two programmable alarm relays and a dedicated alarm for PF correction failure. It is designed for use in mains supplies up to 690V AC and can be used in both single and multi-transformer systems.


Typical Applications

  • Industrial plants with varying inductive loads (motors, transformers, welding equipment)

  • Commercial buildings with HVAC and lighting systems

  • Power distribution substations and utility metering points

  • Renewable energy installations requiring grid code compliance

  • Data centers and critical power infrastructure

Installation and Configuration

Installation of the RVT-6 requires mounting the device on a DIN rail (35 mm) inside a control panel. Voltage and current transformer connections must follow the wiring diagram to ensure correct phase angle measurement. The controller automatically detects phase rotation and CT polarity during initial self-test. Configuration is guided by the LCD menu; users can set CT ratio, target cos phi, switching sequence, response delay, and number of steps. The RVT-6 also offers a "fast learning" mode that adapts to the installed capacitor step sizes automatically.

Maintenance and Reliability

The RVT-6 is designed for long-term reliability with solid‑state outputs and self-diagnostic functions. Periodic inspection should include verifying CT connections, checking for overheating, and cleaning the LCD and ventilation openings. The device records total operating hours and number of switching operations per step, aiding predictive maintenance of capacitor contactors. No routine calibration is required, but annual verification of measured values against a reference meter is recommended.

Conclusion

The ABB RVT-6 power factor controller delivers precise, automated reactive power compensation for improved energy efficiency and voltage stability. With six steps, clear display, Modbus communication, and robust construction, it is a practical choice for electrical professionals seeking to reduce utility penalties and optimize power quality in low-voltage networks.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide