  • Beckhoff EL3164 - 4X Analog Input EtherCAT Terminal
    ❤ Add to collection
  • Beckhoff EL3164 - 4X Analog Input EtherCAT Terminal

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    The Beckhoff EL3164 is a high-performance analog input terminal designed to deliver precise and reliable measurement results in demanding industrial environments. This 4-channel analog input module supports voltage inputs ranging from ±10 V and offer
    • ¥20696.00
      ¥15200.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.140KG
    • Quantity:
    • (Inventory: 5)
Description
The Beckhoff EL3164 is a high-performance analog input terminal designed to deliver precise and reliable measurement results in demanding industrial environments. This 4-channel analog input module supports voltage inputs ranging from ±10 V and offer


Beckhoff EL3164 - 4X Analog Input EtherCAT Terminal

The Beckhoff EL3164 is a high-performance analog input terminal designed to deliver precise and reliable measurement results in demanding industrial environments. This 4-channel analog input module supports voltage inputs ranging from ±10 V and offers 24-bit resolution, making it ideal for applications requiring high accuracy and stable signals. With a maximum sampling rate of 40 kHz per channel, the EL3164 ensures rapid data acquisition, enabling real-time monitoring and control in complex automation systems. Built to withstand harsh conditions, the EL3164 features robust galvanic isolation between channels and the backplane bus, enhancing signal integrity and protecting the system from electrical interference. Its compact design, combined with the proven Beckhoff I/O system architecture, allows seamless integration into EtherCAT-based automation networks, ensuring scalable and flexible system expansion. Furthermore, the EL3164 supports automatic sensor detection and offers diagnostic functions that simplify maintenance and reduce downtime. In terms of durability, the module adheres to industrial standards for temperature ranges and vibration resistance, making it a reliable choice for sectors like power industry, petrochemical, and general automation where operational reliability is paramount. Its precision and stability make it particularly suitable for measuring analog signals in control loops, energy management systems, and process automation tasks. 


The application of the EL3164 in the power industry is evident in scenarios such as turbine monitoring and energy distribution management, where accurate voltage measurements are critical for system efficiency and safety. In the petrochemical sector, the EL3164 excels in process control applications, including monitoring tank levels, pressure sensors, and flow measurement devices, ensuring compliance with stringent safety standards. General automation applications benefit from the module’s fast sampling and high resolution for tasks like quality monitoring, product testing, and machine condition analysis. When compared to other Beckhoff automation products, the EL3164 stands out due to its combination of high-precision input, fast sampling rates, and robust isolation within a compact form factor. For instance, while the Beckhoff EL3102 offers analog input functionality, it supports fewer channels and lower resolution, making the EL3164 a superior choice for applications demanding higher accuracy. Similarly, the Beckhoff EL3214, which is designed for current inputs, complements the EL3164 by covering a wider range of sensor types within a system. Alongside the Beckhoff EL3164, there are several complementary products designed to enhance automation solutions. The Beckhoff CX5120-0115 Embedded PC provides high processing power for complex control algorithms and data handling, while the Beckhoff BK7500 Bus Coupler facilitates modular I/O system integration.


For advanced visualization and operator interface, the Beckhoff CP6907-0001-0010 Panel PC offers a versatile solution. In applications requiring both analog and digital I/O, the Beckhoff EL1809 digital input terminal and the Beckhoff EL2911 analog output terminal can be combined with the EL3164 to create comprehensive automation setups. Additional Beckhoff products such as the CX5140-0111 Embedded PC, the CX2020-0111 Embedded PC, and the CX1100-0930 Embedded PC offer scalable computing power options that can be paired with the EL3164 for optimized control and data processing. Moreover, the Beckhoff BK7200 Bus Coupler and the EL3214 current input terminal provide further system flexibility, allowing users to tailor their automation networks to specific industrial requirements. The application of EL3164 in power industry, petrochemical, and general automation underscores its versatility and reliability. Its ability to deliver precise measurements with high sampling rates supports critical control processes, from energy monitoring to safety system feedback. When integrated with other Beckhoff automation products, the EL3164 forms the backbone of efficient, scalable, and resilient automation architectures. In summary, the Beckhoff EL3164 is an essential component for automation professionals seeking high-precision analog input capabilities within a durable and flexible framework. Its advanced technical features, combined with seamless integration across Beckhoff’s extensive product range, make it a preferred choice for demanding industrial applications. Whether deployed alongside the Beckhoff CX8110 Embedded PC for enhanced processing or integrated with the BK7500 Bus Coupler for extended I/O, the EL3164 consistently delivers exceptional performance and reliability.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide