  • GE VMIVME-2210 Relay Board
    ❤ Add to collection
  • GE VMIVME-2210 Relay Board

    GE VMIVME-2210 Relay Board

    • ¥27500.00
      ¥28520.00
      ¥27500.00
      ¥27500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.700KG
    • Quantity:
    • (Inventory: 33)
Description

GE VMIVME-2210 Relay Board


GE VMIVME-2210 Relay Board

Functional Characteristics

Introduction: 

The VMIVME-2210 provides 64 One Form C (SPDT)  contacts to the user via two 96-pin DIN connectors. These relays  are the magnetic latching type which means that, once a  contact is set it will remain set (even if power is removed from  the relay) until it is reset. All three contact points are brought out  via the connector. They are the N.O. (Normally Open), N.C.  (Normally Closed), and the Common contact points. The N.O. and  the Common can be used to create One Form A contacts while  the N.C. and common can be used as One Form B contacts.  This arrangement permits 64-conductor cables to be used for  Form A switches.

The VMIVME-2210 is populated with double pole relays, but only  one pole is brought out to the user. The other pole is used by the  Built-in-Test (BIT) logic. The state of the controlling Data  Registers or the N.C. poles is read during read accesses of the  board. The Control Registers are located at the same address as  the relays. This allows the user to monitor both the state of the  user contacts and the Control Registers. Because the read pole  and the user’s pole are controlled by the same coil, BIT can monitor the user’s contacts via the N.C. contacts of the second  pole.

Board Functions: 

Sixty-four one Form C latching relay contacts  via two 96-pin DIN connectors. One extra set of contacts (the  N.C. set) is used for BIT. Latching relays hold their state (even  with power removed) until commanded to change.

Compliance: 

The VMIVME-2210 conforms to the ANSI/IEEE STD  1014-1987 IEC 821 and 297 VMEbus specification with the  following mnemonics: A24, A16: 3D/39, 2D/29: D32, D16,  D08(EO): Slave.  

Addressing Scheme: 

The base address of this board contains  the board ID. Stacked above this 16-bit word is a 16-bit CSR. The  Output Registers are placed at the next longword boundary  above the CSR. Finally, the Contact Registers are stacked above  the Output Registers. The Output and the Contact Registers are  addressable as sixteen 8-bit bytes, eight 16-bit words, or four  32-bit longwords, located on any 128-bit boundary within  standard data or short supervisory or nonprivileged I/O space.

Board Addressing: 

Twenty jumpers are used to select the base  address of the board. One jumper determines the address space  (standard data or short I/O) of the board. Another chooses  supervisory, nonprivileged, or either access mode. And the  remaining 18 set up the base address of the board. 

Built-in-Test: Board testing is accomplished by performing a  read operation. Reading the address of the relay in question will  place the state of its Data Register on the bus. Reading the  Contact Register transfers the state of the second N.C. contact  to the bus. Both the data controlling the relay and the contact  state can now be compared. This is done because the relay  takes so long (7 ms maximum) to change its state. With this  information, the user can determine when the relay contacts  have changed state.  

Nonlatching Option: 

If the nonlatching option is ordered, then  standard relays are used. The contact data is not affected.  However, the contacts will NOT hold when power is interrupted.  This option will permit resets and power loss to place the relays  in their normal position. Thus, N.O. contacts will open and the  N.C. contacts will close. All other board operations are the same  as those for the latching version

Features:  

• Latching contacts will hold their state with power off  

• Available in latching and nonlatching versions  

• 1 Form C contacts (SPDT) with 96-conductor cable  

• 1 Form A contacts (SPST) with 64-conductor cable  

• 8-, 16-, or 32-bit data transfers  

• Supports real time and offline fault detection and isolation

• 2.0A current rating  

• Protection from relays changing during power up/down

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice