Product Overview and Application Scenarios
VCP 08 is a compact machine operator terminal used to start various functions of a machine according to application requirements, and can visualize the operation information of the machine/equipment. Its outstanding features lie in its compact structural design and back surround sealing ring, making it widely applicable and supporting any installation posture.
Depending on the variant configuration, this small operating terminal is equipped with either three serial standard interfaces or one fieldbus interface. The front panel adopts a short stroke keyboard, made of 3mm aluminum plate with beveled edges, covered with chemically resistant polyester film on the surface and embossed with key areas.
VCP 08 is developed for single axis or multi axis control tasks, with typical applications including:
Handling and assembly systems
packaging machinery
Printing and paper processing equipment
machine tool
Use boundaries and taboos
VCP 08 is only allowed to operate in a specified posture under specified assembly, installation, and environmental conditions (temperature, protection level, humidity, EMC requirements, etc.). Prohibited usage scenarios include:
Operating conditions that do not meet the specified environmental conditions (such as underwater, extreme temperature fluctuations, or ultra-high temperature environments);
Use without explicit permission from Bosch Rexroth;
Only the accessories and components specified in this manual are allowed to be used, and components not explicitly listed (including cables and wires) shall not be installed or connected;
Only allow to run according to the software and firmware configuration specified in the functional description.
Special attention should be paid: VCP 08 belongs to Protection Class I equipment and must use protective grounding. It is strictly prohibited to use it in scenarios such as construction cranes, passenger and cargo elevators, personnel transportation equipment, medical applications, refineries, hazardous material transportation, nuclear applications, high-frequency sensitive occasions, mining, food processing, and protective device control. The prerequisite for device startup debugging is that the entire machine complies with the regulations, safety standards, and norms of the country where it is located.
Hardware and electrical specifications
3.1 Structure and Panel
Project specifications
Galvanized steel plate for the casing
Front panel aluminum spray painted, 209 × 159 × 3 mm (H × W × D)
Facial mask polyester film
Sealed back circular rubber sealing ring
Installation opening 199 × 139 mm (H × W)
Installation depth is approximately 58mm (excluding connectors)
Protection level: Front IP54/Back IP20
The total weight is about 800 grams
3.2 Display
LCD module with LED backlight, resolution of 120 × 32 pixels, black pixels/yellow green background, viewing angle of 90 °. The contrast setting has temperature compensation function, and the LCD lifespan and backlight half-life are both 100000 hours. Standard font 4 lines x 20 characters (character matrix 6 x 8 pixels), enlarged font character matrix 12 x 16 pixels, display area 38 x 119 mm.
3.3 Keyboard
36 key short stroke button with tactile feedback; The button area is 16 × 16 mm, the stroke is 0.5 mm, the operating force is 2-3 N, and the switch life is about 1 million times.
3.4 Electrical Parameters
Power supply: 24 V DC (SELV compliant with DIN EN 61131), maximum residual ripple of 10%;
Voltage range: 19.2 V -30.2 V;
Power consumption<0.3 A, peak current<0.5 A, connected to a load of approximately 10 W;
Built in semiconductor fuse (self resetting) and reverse polarity protection.
3.5 CPU and Storage
Central processing unit Z84, clock frequency 10 MHz, equipped with watchdog timer, real-time clock, display temperature compensation, and battery monitoring functions. The application memory is 256 KByte Flash, and the RAM is 128 KByte static CMOS-RAM (battery backup).
3.6 Environmental conditions
Operating temperature: 0 ° C to 50 ° C; Storage/transportation: -20 ° C to+70 ° C;
Relative humidity: 10% -95% (no condensation);
Application area: Pollution level 1, overvoltage category II.
3.7 Compliance with Standards
The equipment complies with EN 61131 (equipment requirements, storage and transportation, power supply), EN 60529 (protection level), EN 60068 Part 2-27 (impact) and Part 2-6 (sinusoidal vibration), IEC 60068 (corrosion protection), EMC meets Directive 89/336/EWG and all amendments, immunity covers EN 61000-4-2/-3/-4/-5/-6, and emission interference meets EN 50081-1 Table A1, EN 55011 and EN 55022.
In addition, although the Rexroth control device is developed and tested at an advanced level of technology, it cannot track the development of all materials that may come into contact with the equipment. Therefore, before using new lubricants, cleaning agents, and other materials, compatibility testing must be conducted on the casing/casing material.
Installation and wiring specifications
4.1 Mechanical Installation