Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Honeywell   FC-PUIO01 Safety Systems
    ❤ Add to collection
  • Honeywell FC-PUIO01 Safety Systems

    Honeywell   FC-PUIO01 Safety Systems

    • ¥34000.00
      ¥34670.00
      ¥34000.00
      ¥34000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 47)
Description

Honeywell   FC-PUIO01 Safety Systems


Honeywell   FC-PUIO01 Safety Systems

Universal Marshaling Solution provides standardized marshalling for central and distributed installations using signal conditioning assemblies. The signal conditioning assemblies handle 16 I/O’s including disconnect, fusing as default, and when needed signal conditioning adapters (SCA) including isolation, intrinsic safety, relay, and other functions can be plugged in optionally. The SCA supports standardized cabinet assembly and wiring configurations without the need for custom wiring.

The unique features of UMS include:

• Three level flexible field terminations are provided to cater to various field wiring requirements. 

• The Signal Conditioning Adapters are plugged into the USCA to eliminate the need for a separate installation of isolators, relays, signal converters and barriers. 

• USCA has integral (optional) fuse and knife disconnect for easier plant installation and maintenance. 

• D-Sub connector is provided on the USCA for interfacing with the IOTA. 

• Field power is supplied through the USCA via the system integration cable (SIC) from the Safety IOTA. 

• Optional power connector is provided to supply power to the active signal conditioning adapters. 

• Optional 16 plug and play Signal Conditioning Adapters. 

• Vertical mounting for more effective wiring since most field wiring applications require entry from the top or bottom of the cabinet. 

• An LED for a quick visual cue to draw the Maintenance Technician’s eye to important status information of relay and active signal conditioning adapters.

USCA’s combine multiple functions into a single piece of equipment: 

• Plug and Play adapters for optional signal conditioning. 

• On-board flexible termination of process signals. 

• On-board connection to Safety IOTAs. 

• On-board Field power distribution. 

• USCA receives 24 VDC power. 

• Field disconnect. 

• Field fuse. 

• Probe points for testing

Functions

• Universal Signal Conditioning Assembly – CC-USCA01 is a backplane assembly which can accommodate 16 signal conditioning modules. Field side terminals of each channel is provided with integrated fuse and knife disconnect function. The safety system side interface is provided through a single mass termination cable (SIC) which connects all 16 channels. CC-USCA01 is DIN rail mountable. 

• Universal Pass Through Adapter – CC-UPTA01 is a single channel pass through module which allows direct connectivity between safety system field terminals (both live & return) and the field device. This module does not require external power to operate. 

• Digital Input with 5K resistor Adapter - FC-UDI501 is a single channel digital input module with a 5K resistor for digital input devices without EOL. Output side interfaces with the field device and the input side gets connected to safety system. This module does not require external power to operate. 

• Digital Input Relay with 5K resistor Adapter - FC-UIR501 is a single channel relay input module with a 5K resistor for wet contact applications. Coil side of the relay interfaces with the field device and the contact side gets connected to safety system. This module does not require external power to operate 

• Digital Input Relay Adapter - FC-UDIR01 is a SIL 3 single channel relay input module for low voltage applications. Coil side of the relay interfaces with the field device and the contact side gets connected to safety system. This module does require external power to operate. 

• Digital Output Relay Adapter - FC-UDOR01 is a SIL 3 Normally Open single channel relay output module for low voltage applications. Contact side of the relay interfaces with the field device and the coil side gets connected to safety system. This module does not require external power to operate. 

• Digital Output Relay Adapter F&G - FC-UDOF01 is a SIL 3 Normally Open single channel relay output module for low voltage applications. The adaptor is capable to drive high current field devices. Contact side of the relay interfaces with the field device and the coil side gets connected to safety system. This module does not require external power to operate. 

• Analog Input Adapter, type 3 wire - FC-UAIA01 is a single channel analog input module which supports three wire sensors. Only if used in 3-wire mode, this module requires an external power to operate. This gets connected to the UIO module of the safety system. 

• Analog Input Adapter, type Sink - FC-UAIS01 is a single channel analog input module which supports source type sensors. This module does require an external power to operate. This gets connected to the UIO module of the safety system. 

• Digital Namur proximity switch Adapter - FC-UDIN01 is a single channel digital input module for digital proximity switches. Output side interfaces with the field device and the input side gets connected to the UIO module of the safety system. This module does not require external power to operate. 

• Digital Namur safety proximity switch Adapter - FC-UDNS01 is a single channel digital input module for digital safety proximity switches. Output side interfaces with the field device and the input side gets connected to the UIO module of the safety system. This module does not require external power to operate. 

• Analog Input Barrier Adapter – FC-UGAI01 is a single channel analog input barrier module, for Intrinsically Safe Analog Input devices. Output side interfaces with the field device in a non-Safe zone and the input side gets connected to the USIO module of the safety system. This module does not require external power to operate. 

• Analog Output Barrier Adapter – FC-UGAO01 is a single channel analog output barrier module, for Intrinsically Safe Analog Output devices. Output side interfaces with the field device in a non-Safe zone and the input side gets connected to the USIO module of the safety system. This module does not require external power to operate. 

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement