Description

Honeywell   FC-PUIO01 Safety Systems


Honeywell   FC-PUIO01 Safety Systems

Universal Marshaling Solution provides standardized marshalling for central and distributed installations using signal conditioning assemblies. The signal conditioning assemblies handle 16 I/O’s including disconnect, fusing as default, and when needed signal conditioning adapters (SCA) including isolation, intrinsic safety, relay, and other functions can be plugged in optionally. The SCA supports standardized cabinet assembly and wiring configurations without the need for custom wiring.

The unique features of UMS include:

• Three level flexible field terminations are provided to cater to various field wiring requirements. 

• The Signal Conditioning Adapters are plugged into the USCA to eliminate the need for a separate installation of isolators, relays, signal converters and barriers. 

• USCA has integral (optional) fuse and knife disconnect for easier plant installation and maintenance. 

• D-Sub connector is provided on the USCA for interfacing with the IOTA. 

• Field power is supplied through the USCA via the system integration cable (SIC) from the Safety IOTA. 

• Optional power connector is provided to supply power to the active signal conditioning adapters. 

• Optional 16 plug and play Signal Conditioning Adapters. 

• Vertical mounting for more effective wiring since most field wiring applications require entry from the top or bottom of the cabinet. 

• An LED for a quick visual cue to draw the Maintenance Technician’s eye to important status information of relay and active signal conditioning adapters.

USCA’s combine multiple functions into a single piece of equipment: 

• Plug and Play adapters for optional signal conditioning. 

• On-board flexible termination of process signals. 

• On-board connection to Safety IOTAs. 

• On-board Field power distribution. 

• USCA receives 24 VDC power. 

• Field disconnect. 

• Field fuse. 

• Probe points for testing

Functions

• Universal Signal Conditioning Assembly – CC-USCA01 is a backplane assembly which can accommodate 16 signal conditioning modules. Field side terminals of each channel is provided with integrated fuse and knife disconnect function. The safety system side interface is provided through a single mass termination cable (SIC) which connects all 16 channels. CC-USCA01 is DIN rail mountable. 

• Universal Pass Through Adapter – CC-UPTA01 is a single channel pass through module which allows direct connectivity between safety system field terminals (both live & return) and the field device. This module does not require external power to operate. 

• Digital Input with 5K resistor Adapter - FC-UDI501 is a single channel digital input module with a 5K resistor for digital input devices without EOL. Output side interfaces with the field device and the input side gets connected to safety system. This module does not require external power to operate. 

• Digital Input Relay with 5K resistor Adapter - FC-UIR501 is a single channel relay input module with a 5K resistor for wet contact applications. Coil side of the relay interfaces with the field device and the contact side gets connected to safety system. This module does not require external power to operate 

• Digital Input Relay Adapter - FC-UDIR01 is a SIL 3 single channel relay input module for low voltage applications. Coil side of the relay interfaces with the field device and the contact side gets connected to safety system. This module does require external power to operate. 

• Digital Output Relay Adapter - FC-UDOR01 is a SIL 3 Normally Open single channel relay output module for low voltage applications. Contact side of the relay interfaces with the field device and the coil side gets connected to safety system. This module does not require external power to operate. 

• Digital Output Relay Adapter F&G - FC-UDOF01 is a SIL 3 Normally Open single channel relay output module for low voltage applications. The adaptor is capable to drive high current field devices. Contact side of the relay interfaces with the field device and the coil side gets connected to safety system. This module does not require external power to operate. 

• Analog Input Adapter, type 3 wire - FC-UAIA01 is a single channel analog input module which supports three wire sensors. Only if used in 3-wire mode, this module requires an external power to operate. This gets connected to the UIO module of the safety system. 

• Analog Input Adapter, type Sink - FC-UAIS01 is a single channel analog input module which supports source type sensors. This module does require an external power to operate. This gets connected to the UIO module of the safety system. 

• Digital Namur proximity switch Adapter - FC-UDIN01 is a single channel digital input module for digital proximity switches. Output side interfaces with the field device and the input side gets connected to the UIO module of the safety system. This module does not require external power to operate. 

• Digital Namur safety proximity switch Adapter - FC-UDNS01 is a single channel digital input module for digital safety proximity switches. Output side interfaces with the field device and the input side gets connected to the UIO module of the safety system. This module does not require external power to operate. 

• Analog Input Barrier Adapter – FC-UGAI01 is a single channel analog input barrier module, for Intrinsically Safe Analog Input devices. Output side interfaces with the field device in a non-Safe zone and the input side gets connected to the USIO module of the safety system. This module does not require external power to operate. 

• Analog Output Barrier Adapter – FC-UGAO01 is a single channel analog output barrier module, for Intrinsically Safe Analog Output devices. Output side interfaces with the field device in a non-Safe zone and the input side gets connected to the USIO module of the safety system. This module does not require external power to operate. 

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide