  • PROSOFT ANC-100e Ethernet to Data Highway Plus  Adapter
    ❤ Add to collection
  • PROSOFT ANC-100e Ethernet to Data Highway Plus Adapter

    PROSOFT ANC-100e Ethernet to Data Highway Plus  Adapter

    • ¥36644.00
      ¥36625.00
      ¥36644.00
      ¥36644.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.800KG
    • Quantity:
    • (Inventory: 37)
Description

PROSOFT ANC-100e Ethernet to Data Highway Plus  Adapter


PROSOFT ANC-100e Ethernet to Data Highway Plus  Adapter

DESCRIPTION

The ANC-100e allows you to connect a computer on an Ethernet network to a DH+ network and communicate with various DH+ enabled devices such as Allen Bradley’s PLC5, SLC5/04, SLC5/05, ControlLogix series and other devices which might support Allen Bradley DH+ network connectivity. ANC-100e is designed to work utilizing the Ethernet/IP network driver available in most industrial communication software suites, such as Allen Bradley RSLinx Classic/Gateway/Enterprise and alike. And its auto-configuration features provide a quick and easy connection, as cable polarity, node number and baud rate can be auto-detected and auto-configured. For more information on properly configuring your software suite of choice to work with ANC-100e.

Using ANC-100e

Power and protection

Device requires 9…24 V DC power supply and consumes, depends of the voltage from 94mA at 9V to 35mA at 24V. Device has a diode protection against wrong power wiring polarity.All device inputs (power, DH+, Ethernet) are TVS protected from spikes and transients.Connect the power supply + and – wires to the appropriate connection points on the power connector supplied with the device. Please reference the figure on the left for proper wiring.System grounding in most cases is not necessary but may be useful for protection against high power spikes.

Connections

To connect ANC-100e device to your existing DH+ network or directly to another DH+ device, please use one of the connectors included with the product.

1. Connect the DH+ cable to the ANC-100e left most and right most terminals of the Phoenix 3 pin connector leaving the middle pin not connected. The polarity of blue and clear cables does not matter 

2. Connect ANC-100e to the Ethernet network or a free Ethernet port on the computer or a free Ethernet port on a network hub/switch 

3. The “Ethernet” LED light should blink intermittently for a moment 

4. The “DH+” light will blink every 3 seconds indicating that the device is connected and associated to a DH+ network

LED Diagnostics

ANC-100e is equipped with three LEDs used for visual status and diagnostic display.

LED labeled “Ethernet” indicates the data exchange between the ANC-100e and the user PC or any device on the Ethernet network. When the device sends/receives a packet to/from the PC/Ethernet Network, this LED blinks indicating packet exchange.

LED labeled “Diag” indicated the current status of the ANC-100e device on the DH+ network:

• “LED Solid Red” indicates that the device is not currently associated on a DH+ network. 

• “LED Solid Green” indicates that the device is associated on the DH+ network

LED labeled “DH+” indicates the current status of the DH+ network:

• “LED Off” indicates that there is no application level traffic coming into or out of the device. 

• “LED blinks without any particular pattern of Green and Yellow” indicates that the device is associated with the DH+ network and there is ongoing communication taking place with other nodes on the network. Packet transmission causes Yellow LED to blink, packet reception is indicated by a Green blink.

Main Configuration Window

The following information is displayed in the main configuration window:

• “Fw Version:” field displays the current Firmware version of the device 

• “Serial #:” field displays the unique serial number of the device 

• “DHCP” field allows the user to enable a DHCP client on the device to obtain dynamic IP address from a DHCP server on the Ethernet network, instead of using static IP parameters specified by the user 

• “IP address:” field displays the current IP address of the device, and allows the user to modify it is desired 

• “IP Mask:” field displays the current network mask of the device, and allows the user to modify it if desired 

• “IP Gateway:” field displays the current default gateway configured on the device, and allows the user to modify it if desired 

• “DH+ Node:” drop down menu displays the current DH+ node settings for the device, and allows the user to change it if desired. By default, device is set to automatic DH+ node assignment; please see the description of this feature at the beginning of this chapter 

• “DH+ Baud Rate:” drop down menu displays the current DH+ network speed the device is configured to use, and allows the user to change it if desired. By default, device is set to automatic DH+ speed detection; please see the description of this feature at the beginning of this chapter

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide