Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

How to avoid the risk of open-pit mining, 24 prevention and control points to ensure production safety

来源: | 作者:佚名 | 发布时间 :2023-12-21 | 524 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

(2) Vehicle sinking accident

Because the stone open-pit mine road is not strictly built in accordance with the mine road design specifications, the road is not compacting, in case of bad weather, the road softens and sinks, when the vehicle is driving on the softened road, there will be a sinking phenomenon, resulting in vehicle driving map difficult, and even accidents.

(3) Vehicle skid

The slope of the mine road is steep, the road slope is large, and the road is slippery, and the skid of the mine vehicle is common. If it is serious, it will even cause the vehicle to tip over and cause a major safety accident. Figure 4 is a granite mine, and the mining surface forms an obvious steep slope compared with the highway, which is easy for the vehicle to slip.

(4) Vehicle breakdown on the road

Vehicle failure, vehicle overload leads to trapped in the road accident. Although the vehicle breaking down on the road does not lead to serious safety accidents, it will seriously affect the normal progress of production and cannot be underestimated.

(5) Road collapse

Due to the large investment in the construction of roads in open-pit stone mines, some mine owners will not invest a lot of money in the road construction that does not produce a return on the principle of saving on the province, resulting in mine roads not strictly in accordance with the requirements of the design Code for open-pit mine road construction, resulting in road landslides seriously affecting mine production.

3. Prevention and control of road safety risk points in open-pit mines

(1) Risk prevention and control of vehicle rollover accidents

The prevention and control of vehicle accident risk in stone open-pit mines should pay attention to the following aspects: road construction should be carried out in strict accordance with the "Code for Road Design in open-pit Mines", and the construction quality of road construction should be well paid to reduce the accident risk of vehicle rollover caused by poor road construction quality.

Mine road conditions should be checked regularly, timely detection of road safety hazards, strengthen the management of vehicle drivers, and prohibit unlicensed driving. Strengthen the management of vehicle personnel, strictly prohibit illegal driving, and improve the sense of responsibility of drivers. Vehicles and quarrying operations are strictly prohibited in bad weather.

Risk warning signs should be set up in sections with large cliffs and drops to remind vehicle drivers to drive safely, and firm safety protection facilities should be set up to prevent the further deterioration of safety accidents when vehicles roll over.

(2) Risk prevention and control of vehicle sinking accidents

Vehicle sinking accidents are mostly caused by soft road surface and roadbed collapse. The key to control this kind of accident risk is to strengthen the control of road pavement construction quality. The road construction should be carried out in strict accordance with the "Code for Road Design of Open Pit Mines" to improve the construction quality of mine roads. Regular inspection of mine road conditions, timely detection of road safety hazards.

Strictly control vehicle overloading and speeding. Overload is a common phenomenon in stone mines. Mining enterprises in order to produce more ore, truck drivers in order to DORA goods to make money, regardless of safety risks. In order to curb the risk of vehicle sinking, subjective management in this respect should be strengthened, and the behavior of overloading and speeding should be severely cracked down on.

(3) Prevention and control of vehicle skid risk

The prevention and control of vehicle skid risk should be strengthened from the following points:

Road construction is carried out in strict accordance with the "Code for Road Design in Open Pit Mines", and the construction quality of road construction is paid attention to, especially the quality of road pavement. Mine road conditions should be inspected regularly, and mine roads should be regularly maintained, repaired and compacted. Eliminate the safety hazard of road slip. Vehicles and mining operations are strictly prohibited in inclement weather such as snow, ice and heavy rain. Anti-skid measures should be taken when work is necessary

(4) Risk prevention and control of vehicle breakdown

The risk of vehicle throwing wrong on the road is mostly due to vehicle failure. The focus of risk control is to strengthen vehicle inspection and strengthen daily maintenance and repair.

Strengthen the maintenance and inspection of roads, and clean up stones that are easy to puncture tires. It is strictly prohibited to overload and control the load of the vehicle.

(5) Prevention and control of road collapse risk

The risk of road collapse is mostly caused by major problems in road quality, strengthen the quality of road construction, daily inspection of roads, timely discovery of road safety hazards, and timely repair.

Road subgrade and road slope are the key places of road collapse risk management. Mine management personnel should establish technical data file management for roadbed and slope with wall risk, and have technical measures and emergency plans to prevent road collapse.

  • ABB DSAI130DK01 3BSE020828R1 Analog Input Module
  • Parker 466966-0001-3820 Industrial Component Data
  • PARKER ZETA6104 Microstepping System
  • PARKER COMPAX 2500S/F3 Servo Drive Manual Details
  • PARKER CX-DH Indexer Drive Technical Specifications
  • PARKER 6K8 Motion Controller Features and Specifications
  • PARKER EVM32-BASE I/O Module Base Technical Specification
  • ABB Pb PN-112718 Digital Input Module
  • Pb PN-45734 PN-73899 Industrial Automation Module
  • Control Techniques Pb PN-40856 Industrial Control Module
  • Pb PN-104412 4002910956 Industrial Control Module
  • Siemens Pb PN-41513 Industrial Ethernet Module
  • Pelco PA30-0065-00-A1 PTZ Decoder Module
  • Pentek FILTER 3F11 800000919 Pleated Filter Cartridge
  • Pepperl+Fuchs RSD-TI-EX8 Temperature Input Module
  • PERITEK AC7-00712-1113 Industrial Interface Module
  • PFEIFFER EVR116 Vacuum Control Module
  • Pepperl+Fuchs RSD-CI-EX8 Hazardous Area Interface Module
  • PEPPERL+FUCHS 2108HAT Intrinsic Safety Barrier Module
  • Philips 958481320201 PROC+ Processing Unit
  • Philips 958481321300 PSB Power Supply Board
  • Philips 958481321220 PD208 Power Module
  • PHILIPS 958481321200 PD216 Control Module
  • PHILIPS 958481320201 PROC PLUS Control Module
  • Philips 958481320400 PIF Interface Module
  • Philips 958481320100 LCB Control Board
  • PHILIPS 958481223220 Industrial Control Module
  • PHILIPS 958481223223 Industrial Control Module
  • PHILIPS 958481321300 Industrial Control Module
  • PHILIPS SCM040 Digital Output Synchronization Module
  • PHILIPS DSI020 Data Storage Interface Module
  • PHILIPS OPM010 Optoelectronic Control Module
  • PHILIPS VBM010 Industrial Automation Module
  • PHILIPS VBM030 Turbine Supervisory Instrumentation
  • PHILIPS PR1613 Industrial Control Module
  • PHOENIX PATG1/23 1013847 Ground Terminal Block
  • Phoenix Contact IB ST 24 AI 4/SF Analog Input
  • Phoenix Contact OPC5315-004-AB Industrial PC
  • Phoenix Contact UMK-SE11.25-1 Side Element
  • PHOENIX 2961192 Relay Module
  • PHOENIX IB ST ZF 24 AI 4/SF Analog Input Module
  • Phoenix Contact PLC-BSC-24DC/21 Relay Base
  • Phoenix Contact UK6N Feed-Through Terminal Block
  • Phoenix Contact UK4-T Disconnect Terminal Block
  • Phoenix UK3N Screw Terminal Block
  • Phoenix QUINT-PS-100-240AC/10 Power Supply
  • Phoenix QUINT PS-100-240AC/24DC/10 Power Supply
  • Phoenix UT 6-HE SI Surge Protection Terminal Block
  • Phoenix UT 4-MTD Feed-through Terminal Block
  • Phoenix UT 4-HE SI Surge Protection Terminal Block
  • Phoenix IBS 24BK-I/O-T Bus Coupler
  • Phoenix Contact HDFK4 High-Current Terminal Block
  • PHOENIX ST-SI-UK4 Fuse Terminal Block
  • PHOENIX FLMC10BASE-T/FO G850 Fiber Media Converter
  • PHOENIX CONTACT QUINT-PS-100-240AC/24DC/40 Power Supply
  • PHOENIX CONTACT QUINT-DIODE/40 Redundancy Module
  • Phoenix Contact 2884208 Wireless I/O MUX
  • Photonetics 3646 HE 1540 Tunable Laser Source
  • PI C-663.12 Mercury Multi-Axis Step Motor Controller
  • PI C-663.10 Mercury Step Motor Controller
  • Pillar CB6687-2L Industrial Communication Board
  • Pilz DE-106712 A.F.051.5/01 Safety Module
  • Pilz 680003 Safety Relay Module Set
  • Pilz 301140 PNOZ X3 Safety Relay
  • Pilz P1U-1NB Safety Relay
  • Pioneer PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3326B-6-1-2-E Power Supply
  • Pioneer Magnetics HYRSP-1500-56 Power Supply
  • Pioneer Magnetics PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3328BP-6 Power Supply
  • Potter & Brumfield SDAS-01-7Y2S1024 Relay
  • Powec PMP10.48 SIC High-Efficiency Rectifier
  • Powerbox PU200-31C Industrial DC-DC Converter
  • PIONEER MAGNETICS PM3398BP-6-1-3-E Power Supply Module
  • PIONEER MAGNETICS PM1253AL-6-3-Z03 Power Supply Module
  • Powerex PD411811 Rectifier Diode Module
  • Power-One MAP55-1024 AC-DC Power Supply
  • ProSoft MVI56-MDA4 ControlLogix Multi-Protocol
  • POLYSPED PRD2-200 Industrial Drive Module
  • P-OPEN P-OPEN-P4-150 PAC-OP150 Operator Panel
  • ABB Processor 958481321210 350211080320 Rugged CPU
  • ABB Processor 958481320201 350211080460 Safety CPU
  • ABB Processor 958481321200 350211080320 CPU Module
  • ABB Processor 958481321220 350211080320 CPU Module
  • ABB Processor 958481320100 350211080090 CPU Module
  • Pro-Face PL5901-T42-24V HMI Touch Panel
  • PROFIBUS PB3-VME-1-E V1.2.2 Interface Card
  • PROMESS 850040060P Force Displacement Monitor
  • PROSOFT AN-X2-AB-DHRIO DH+ and Remote I/O Gateway
  • PROSOFT RLX2-IFH24E Industrial Wireless Radio Module
  • PROSOFT 5202-DFNT-MCM4 DF1 to EtherNet/IP Gateway
  • PROSOFT PLX35-NB2 EtherNet/IP to Modbus TCP Gateway
  • ProSoft 5201-MNET-MCM-WEB Modbus TCP/Serial Gateway
  • ProSoft 5304-MBP-PDPMV1 Modbus Plus to PROFIBUS DP Master
  • ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave
  • ProSoft 5301-MBP-DH485 Modbus Plus to DH485 Gateway
  • ProSoft 6104-WA-PDPM Wireless PROFIBUS DP Master
  • ProSoft MVI56-LTQ ControlLogix Limitorque Master
  • Prosoft 5304-MBP-PDPM PROFIBUS Master Module
  • Prosoft 1452-25M Relay Output Module
  • Prosoft MVI56-MNETR Modbus TCP/IP Module
  • Prosoft MVI69L-MBS Modbus Serial Module
  • Prosoft PLX32-EIP-SIE Ethernet Gateway
  • Prosoft MVI56-PDPS PROFIBUS DP Slave Module
  • Prosoft PMF1327205 Gateway Module
  • Prosoft PMF1216D61 FOUNDATION Fieldbus Module
  • PROSOFT MVI56-GSC Generic Serial Communication Module
  • PROSOFT 5601-RIO-MCM Remote I/O Communication Module
  • PROSOFT 1454-9F Communication Interface Module
  • PROTECH SYSTEMS PBI-6SA Industrial Single Board Computer
  • PRSTECH DMP10.24-20 DIN-Rail Power Supply
  • PRT PSA300R-81 Industrial Power Supply Module
  • PULS SLA8.100 AS-Interface Power Supply
  • QSI QTERM-K65 Industrial Operator Interface
  • R-2528Z R-2528Z Industrial Specialized Component
  • Radisys SBC486DX66 Single Board Computer
  • Radisys EPC-5 with EXM-13 Embedded System
  • Radisys EPC-16 Embedded Computer
  • Ramix PMC676TX PMC Ethernet Adapter
  • Ramix PMC008A PMC-to-VME Adapter
  • Ramix PMC237C-008EMI PMC Carrier
  • Ramix PMC661J PMC Carrier Board
  • Renata CR2450N Lithium Battery
  • Renault Circuit CU-8593-IND.A Control Module
  • Reotron 567LH-DP24 Voltage Regulator
  • RIFA IC693PWR321U GE Fanuc Series 90-30 Power Supply
  • RKC REX-B871NN-CS1B Intelligent Controller
  • RKC B871-RCU Digital Temperature Control Unit