BENTLY 1900/65A General Purpose Equipment Monitor

来源: | 作者:FAN | 发布时间 :2025-09-19 | 465 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

BENTLY 1900/65A General Purpose Equipment Monitor

Description

The 1900/65A General Purpose Equipment Monitor is  designed to continuously monitor and protect equipment that is used in a variety of applications and industries.  The monitor’s low cost makes it an ideal solution for general purpose machines and processes that can benefit from continuous monitoring and protection.
Inputs
The 1900/65A provides four transducer inputs and four temperature inputs.  Software can configure each transducer input to support 2- and 3-wire accelerometers, velocity sensors or proximity sensors.  Each temperature input supports Type E, J, K, and T thermocouples, and 2- or 3-wire RTDs.

Outputs

The 1900/65A provides six relay outputs, four 4-20 mA recorder outputs, and a dedicated buffered output.  The user can use the 1900 Configuration software to configure the relay contacts to open or close according to the OK, Alert and
Danger statuses of any channel or combination of channels, and to provide data from any variable from any channel on any recorder output.  The dedicated buffer output can provide the signal for each transducer input.
A Modbus Gateway option allows the monitor to provide static variables, statuses, event list, time and date information directly to any Modbus client, including Distributed Control Systems (DCSs), Supervisory Control and Data Acquisition (SCADA) systems, Programmable Logic Controllers (PLCs), or System 1 software.  The monitor uses an internal counter and a Modbus client/master time reference to generate time and date information.  Users can upgrade monitors without the Modbus Gateway by ordering the 1900/01 Communications Upgrade (see the Ordering Information section).  The 1900/65A supports Modbus communications via Ethernet and a software-configurable RS232/485 serial port.

Configuration

The user defines monitor operation and the Modbus Gateway register map by using
software running on a laptop or PC to create a configuration file and download the file to the monitor through the built-in Ethernet connection.  The 1900/65A permanently stores configuration information in non-volatile memory, and can upload this information to the PC for changes.
Display Module
The 1900/65A supports an optional display/keypad to view channel information or
make minor configuration changes. This allows the 1900/65A to operate as a stand-alone package.  If desired, the user can mount the display up to 75 metres (250 feet) from the Monitor Module.

Specifications
Inputs
Transducer Inputs
Users can configure Channels 1 through 4 to accept input from acceleration, velocity or displacement transducers.
Transducer Channel Types
Channel Types define the functionality for processing that will be applied to an input signal and the kind of variables or measurement values that will be derived from this input.  Channel Types also define the kind of sensor that must be used.  Transducer Channel Types include:
Acceleration or Reciprocating Acceleration
Velocity or Reciprocating Velocity
Radial Vibration (shaft vibration)
Thrust (shaft axial displacement)
Position
Speed


Acceleration and Reciprocating Acceleration Channel Types

The Acceleration Channel Type and Reciprocating Acceleration Channel Type support two- and three-wire acceleration sensors.  The Reciprocating Acceleration
channel type has timed OK channel defeat disabled.
Acceleration Variables and Reciprocating Acceleration Variables
Acceleration Variables and Reciprocating Acceleration Variables are filtered and
processed measurements from raw transducer signals.  The Acceleration
Channel Type and Reciprocating Acceleration Channel Type continuously processes up to four variables per channel.
Vibration:Up to three bandpass filtered amplitude measurements.
Acceleration :Users can apply the acceleration enveloping algorithm to one Acceleration or Reciprocating Acceleration Variable.
Enveloping:Bias Voltage Users may assign the value of the transducer bias voltage to any of the variables.

Filters
Vibration Variable: 0.5 Hz – 25 kHz configurable 4-pole high pass, 4-pole low-pass
Enveloping High-Pass:25 Hz to 5 kHz, configurable 4-pole
Enveloping Low-Pass:125 Hz to 25 kHz, configurable 2-pole
Enveloped Variable High Pass: 0.1 Hz min., but greater than Enveloped Variable low-pass 2-pole
Enveloped Variable Low Pass:Greater than Enveloped Variable high-pass and less than Enveloping high-pass 4-pole
Bias Filter:0.01 Hz 1-pole low-pass
OK Filter:2.4 kHz 1-pole low-pass
Full Scale Range
Vibration:20 to 500 m/s2 (2 to 50 g) peak and RMS
Enveloped:20 to 500 m/s2 (2 to 50 g) peak and RMS
Integrated:10 to 100 mm/s (0.4 to 4 in/s) peak and RMS
Bias Voltage:-24 V
Accuracy
Vibration Variables: ±1% of full scale range
Input Impedance
3-wire Voltage Mode;10 kΩ


Velocity and Reciprocating Velocity Channel Type
The Velocity Channel Type and Reciprocating Velocity Channel Type support two-wire and three-wire piezo velocity sensors.
Velocity Variables and Reciprocating Velocity Variables
Velocity Variables and Reciprocating Velocity Variables are filtered and processed measurements from raw transducer signals.  The Velocity Channel Type and Reciprocating Velocity Channel Type support up to four continuously calculated variables per channel.
Vibration
Up to three bandpass filtered amplitude measurements
Bias Voltage
Users may assign the value of the transducer bias voltage to any of the variables.

image.png

Configurable Options
Each variable is independently configured with the following options.
Vibration Variables:
Peak or RMS Metric or English units
Filter corner frequencies
Full-scale range
Velocity integrated to displacement
Filters
Vibration Variables:0.5 Hz to 5.5 kHz, configurable 8-pole high pass, 4-pole low-pass
Bias Filter:0.09 Hz 1-pole low-pass
OK Filter:2.4 kHz 1-pole low-pass
Full Scale Range
Vibration:10 to 50 mm/s (0.5 to 2 in/s) peak and RMS
Integrated:100 to 500 μm (5 to 20 mils) peak to peak
Bias Voltage:-24 V
Accuracy
Vibration Variables: ±1% of full scale range
Input Impedance
3-Wire Voltage Mode:10 kΩ


Compliance and Certifications
FCC
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
EMC
EN 61000-6-2: 2005  
EN 61000-6-4: 2007 +A1:2001
EMC Directive 2014/30/EU
Electrical Safety
EN 61010-1: 2010
LV Directive 2014/35/EU
ATEX
EN 60079-0: 2012
EN 60079-15: 2010
ATEX Directive 2014/34/EU
RoHS
RoHS Directive 2011/65/EU
Maritime
ABS 2009 Steel Vessels Rules
1-1-4/7.7,4-8-3/1.11.1,4-9-7/13

image.png

Hazardous Area Approvals
This monitor is not certified for installation in Class 1 Div 1 locations, but it will support transducers installed in Div 1 locations via the use of galvanic isolators and barriers. If galvanic isolators are used, no change is necessary to the installation. A removable ground jumper allows the monitor to support zener barrier installations. Removing the jumper will disconnect circuit common from chassis at the monitor so that chassis can be connected at the barrier.
Special Considerations
Hazardous area installations require relay contact voltages below 30 Vac rms, or 30 Vdc to minimize hazard.Hazardous area installations require relay contact amperages  below 5 Amps DC, or AC to minimize hazard


Hazardous Area Approvals
This monitor is not certified for installation in Class 1 Div 1 locations, but it will support transducers installed in Div 1 locations via the use of galvanic isolators and barriers. If galvanic isolators are used, no change is necessary to the installation. A removable ground jumper allows the monitor to support zener barrier installations. Removing the jumper will disconnect circuit common from chassis at the monitor so that chassis can be connected at the barrier.
Special Considerations
Hazardous area installations require relay contact voltages below 30 Vac rms, or 30 Vdc to minimize hazard.Hazardous area installations require relay contact amperages  below 5 Amps DC, or AC to minimize hazard

image.png

  • ELAU DB-5 Distribution HW 5104 Servo System
  • Touchstar 10K TS10KCC0CEMP Industrial Touch Panel
  • Beckhoff CX2030-0125 Embedded PC PLC
  • Parker Hannifin HID5CS/S4 HIDRIVE 5A Servo Drive
  • Yaskawa ACE-P300-TH5 Servo Drive with Profibus
  • Omron Sysmac SCY-P0 13E Sequencer Controller
  • Saia Burgess PCD4.M120 PCD4.M12 Central Controller
  • Schneider Electric TSX3722101 Modicon Micro PLC
  • Siemens Micromaster 440 6SE6440-2AD25-5CA1 Inverter
  • SICK DL50-P1123 Distance Sensor
  • Yaskawa SGDH-04AE-OY Servo Driver 200V 400W
  • Cincinnati Milacron 3-542-1203A Circuit Board Module
  • Allen-Bradley 1756-EN2T EtherNet/IP Communication Module
  • OMRON CS1H-CPU66-V1 Programmable Logic Controller
  • ABB SACE TMAX S6N 630 Molded Case Circuit Breaker
  • Weidmuller IE-SW-VL16-16TX 16-Port Ethernet Switch
  • Schneider PowerLogic CM4250 Circuit Monitor
  • Sacmi IDPM IDMP1.A SMC 085.16.982 Control
  • Omron C120-LK202-EV1 Host Link Unit
  • Omron FQ2-S15050F Smart Camera Vision System
  • OMRON CJ1G-CPU44H Programmable Logic Controller
  • SIEMENS KTP600 HMI 6AV6 647-0AD11-3AX0 Touch Panel
  • OMRON CS1G-CPU45H EV1 Programmable Logic Controller
  • Omron C200HG PLC System C200H-ID212 C200H-OC226
  • ROBOSYSTEM IOG4AX-HD-100 IOG-HD Motion Controller
  • Datalogic SG4-S3-080-PP-W Safety Light Curtain
  • Omron NS12-TS01B-V2 Interactive Display
  • Esto Electronic E.CGT-405-42TE PLC Rack
  • Siemens 7ED62 Static Three Phase Counter
  • Oemer QCAVS 100 LBE AC Square Frame Servo Motor
  • Schneider Electric TM262M25MESS8T Motion Controller
  • Eaton Moeller MFD-CP8-ME Power Supply
  • Pro-face PL-5700T1-24VDC Industrial Panel PC
  • GE Fanuc IC693APU300J High Speed Counter
  • Fuji Electric Micrex-F FPU080S PLC Module
  • Automation Direct GS2-45P0 AC Drive
  • Omron 3G3MV-C4015 V1000 Inverter
  • Vacon NXI01055A2T0CSS Industrial Inverter
  • Saia Burgess PCD4.M240 Central Controller Module
  • Yaskawa SGDH-10DE Sigma II Servo Drive
  • Stober EK501USOM140 Servo Motor and Drive
  • SCE M68-2000/4 CNC Controller and I/O Board
  • Omron SP10-PR001-V1 PLC Programming Console Specs
  • VACON NXI01055A2T0CSSA Industrial AC Drive
  • OMRON SYSMAC SCY-P1 Sequencer Controller PLC
  • SEL-2440 DPAC Discrete Programmable Controller
  • BIVIATOR CI3098 CPU Encoder Module Industrial Control Unit
  • Siemens 6FC5371-0AA10-0AA2 SINUMERIK NCU 710.2
  • KOLLMORGEN SERVOSTAR S70601-NA High Performance Servo Drive
  • OMRON C200HW-PCU01 Fastnet PCMCIA LAN Communication Unit
  • ibaFOB-2io-D Two-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-D Four-Channel Fiber Optic Input Output Card
  • ibaFOB-io-S Single-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-S Four-Channel Fiber Optic Input Output Card
  • ibaFOB-4o Four-Channel Fiber Optic Output Interface Card
  • ibaFOB-4i-S Enhanced Four-Channel Fiber Optic Input Card
  • ibaFOB-4i Four-Channel Fiber Optic Input Interface Card
  • ibaFOB-io Fiber Optic Interface Card for iba Systems
  • SM128V VMEbus Interface Card for Industrial Data Acquisition
  • ibaLink-SM-128V-i-2o VMEbus Fiber Optic Interface Board
  • GE Fanuc IC693MDL632 125V DC Input Module 8 Points
  • GE Fanuc IC693MDL241 24V AC/VDC Input Module 16 Points
  • GE Fanuc IC693MDL240 120V AC Input Module 16 Points
  • GE Fanuc IC693MDL231 240V AC Isolated Input Module
  • GE Fanuc IC693MDL230 120V AC Isolated Input Module
  • GE Fanuc IC693MDL654 5/12 VDC 32-Point Input Module
  • GE Fanuc IC693MDL653 24 VDC 32-Point Input Module
  • GE Fanuc IC693MDL648 48 VDC 16-Point Input Module
  • GE Fanuc IC693MDL646 24 VDC 16-Point Input Module
  • GE Fanuc IC693MDL634 24 VDC Input Module 8 Points
  • GE IM 3100 D 1007722 Control Module
  • GE IM0146B Industrial Circuit Board
  • GE IM0059E0-10070 Interface Board
  • GE IM0094C Industrial Control Board
  • GE IC200PNS002-AB VersaMax PROFINET Scanner
  • GE F650BFBF1G0HI Feeder Protection Relay
  • GE TPR5616NRHC Protection Relay
  • GE D6P3KH Digital Protection Relay
  • GE F650BABF2G0HIS Feeder Protection Relay
  • GE F650BADF2G1HIR Feeder Protection Relay
  • GE F650BABF2G1HI6 Digital Bay Controller
  • GE Multilin 745-W2-P1-G1-H-I-A-R-E Transformer Protection Relay
  • GE 100BASE-T Industrial Ethernet Interface
  • GE Multilin 350-E-P1-S1-H-S-E-C-N-2E-D-H Feeder Protection System
  • GE F650MXCF1G1HI6 Bay Controller
  • GE MM300-GEHD2CAB Motor Management Relay
  • GE MMS35-621-1-00 Motor Management System
  • GE 100BASE-T Ethernet Communication Module
  • GE F650MFCF1G1HI6 Feeder Protection Relay
  • GE CK13BA300 Control Module
  • GE W2-P1-G1-H Industrial Control Unit
  • GE PIB315B Power Interface Board
  • GE 343L695VAGIRHC Multi-Function Relay
  • GE Multilin B90N05HKHF8NH6 Bus Differential Protection
  • GE ZX3SC0204N-930 Intelligent Control Module
  • GE PIB504 Process Interface Board
  • GE D20MX Remote Terminal Unit
  • GE T60UJ3HKHF8NH6 Transformer Protection Relay
  • GE ZG3SA02041-58S600X Motor Protection Relay
  • GE ZG3SA02041-58S Motor Protection Relay
  • ABB DSDX 452 L Remote Input Output Module
  • ABB RDCU-02C Drive Control Unit
  • ABB COMMANDER 350 Process Controller
  • ABB Tmax XT4S 250 Molded Case Circuit Breaker
  • DEIF MALLING 8027.90 Industrial Control Unit
  • DEIF DCP2-2410 Power Supply Module
  • DEIF FAS-2N Synchronizer
  • DEIF MALLING 827.54 Processor Module
  • DEIF DU-2/MKIII Display Unit
  • DEIF DRW-2 Reverse Power Relay
  • DEIF 827.4 Power Management Module
  • DEIF 1044220060F Mains Measurement Module
  • DEIF 1044220190G Remote Display Module
  • DEIF 1044220140C AGC 200 Display Module
  • DEIF BRW-1-NB Remote Display Unit
  • DEIF MALLING 827.52 Industrial Control Unit for Automation Systems
  • DEIF BRW-2 Industrial Relay Module for Control Systems
  • DEIF 1044220080D Power System Control Module Industrial Automation
  • DEIF 1044220100F Controller Module for Generator Control Systems
  • DEIF DU-300 Voltage Monitoring Relay Industrial Protection Unit
  • DEIF 1044220060F I/O Extension Module
  • DEIF 1044220150C Interface Module
  • DEIF GCU 100 Engine Control Unit
  • DEIF XDI144-DUAL Marine Indicator
  • DEIF 827.41 Multi-line 2 Processor Module
  • DEIF AGC 146 Automatic Genset Controller
  • DEIF 1044220080E MDR-2 Display Module
  • DEIF MDR-2 Multifunctional Digital Relay