Local control and external control
Transmission has two main controls: external and local. The selection of the control location can be done by using the LOC/REM key on the control panel, or by using the PC tool.
Local control
When the drive is set to local operation mode, the control instructions are either from the keys on the control panel or from the mount
DriveComposer is issued on the PC tool. For local control, speed and torque control modes can be used;
When the scalar motor control mode is used, the frequency control mode can be used (see Parameter 19.16 Local Control Mode).
Local control is mainly used for commissioning and maintenance. When the control panel is used in local mode, the control panel instructions take precedence over the external control signal source. You can use parameter 19.17 to disable Local control to switch the control mode to the external mode.
The user can select the response of the drive when the communication between the control panel or PC tool and the drive is interrupted by the parameter (49.05 Communication Loss Action). (Parameters have no effect on external control)
External control
When the drive is under external control, the control instructions are given by:
• I/O ports (digital and analog inputs).
• Embedded fieldbus interface or optional fieldbus adapter module
• External (DDCS) controller interface
• Master/slave link, and/or
• Control panel.
The drive has two external controls, EXT1 and EXT2. Users can use parameter 20.01... 20.10 Set the start and stop instructions for each external control. The operating mode can be selected individually for each external control (parameter group 19 operating modes), allowing free and fast switching between the two external control modes, such as speed and torque control. EXT1 or EXT2 can be activated from any binary source, such as a numeric input or fieldbus control word (see Parameter 19.11 External 1/ External 2 selection). A given source for each running mode can be selected independently.
Use the control disk as the external control source
The control panel can also be used as a start/stop command and/or given signal source in external control. The control disk can be selected in the start/stop command source and given source selection parameters.
The given source selection parameter contains two options for the control disk. The difference between the two options is the initial given after the given source switches to the control panel.
Each time another given source is selected, the control disk Settings are saved. If the given source selection parameter is set to the control disk (a saved given) external 1/ external 2 selection, the saved value can be used as the initial value after the control is switched back to the control disk. Note that only one type of given can be saved at a time: for example, try in different operation modes
Using the same saved setting under formula (speed, torque, etc.) will cause the inverter to trip due to the 7083 control panel given conflict. Control disk Settings can be individually restricted by parameters in group 49 control disk interface communication.
After setting a given source selection parameter to a control disk (a copied given), the initial setting of the control disk depends on whether the mode of operation changes with the given source. If the source switches to the control disk and the mode of operation does not change, the last given from the previous source is taken. If the operating mode changes, the actual value of the inverter corresponding to the new mode is used as the initial value.
The working mode of the transmission
The drive can operate in several different types of given control modes. You can select the control mode for each control place (Local, EXT1, and EXT2) in parameter group 19 Run Mode.
Rotational speed control mode
The motor rotates at the given speed of the transmission. In this mode, the estimated value can be used as the speed feedback value, and the encoder can be used to obtain higher speed accuracy.
Speed control mode can be used in both local control mode and external control mode. The same applies to vector control and scalar motor control modes.
Torque control mode
The motor torque rotates according to the torque given by the transmission. Torque control can be feedback-free, but is more dynamic and accurate when used with a feedback device, such as an encoder. Feedback devices are recommended for crane, winch or hoist control.
For both local control mode and external control mode, torque control mode can be used in vector motor control mode.
Frequency control mode
The motor rotates according to the frequency given by the transmission, and the frequency control is only effective in the scalar motor control mode.
Special control mode
In addition to the above control modes, the following special control modes can be provided:
• For more information, see Electropotentiometer (page 47).
• Scram modes Off1 and Off3: The drive stops in accordance with a defined deceleration ramp, or modulated stops.
• Point mode: When the point signal is activated, the drive starts and accelerates to the given speed according to the defined acceleration time. For more information, see Point-and-click functions (page 41).
Choose Xiamen control Smith after sale worry
Excellent product quality
Only cooperate with manufacturers of first-line brands in the industry
Imports/Products
Good pre-sale service
Communicated with customers repeatedly about product model, quality, price and delivery date
Work with the customer to determine the best solution
Address user concerns in advance
Business execution in place
Ordered products delivered on time
Make perfect delivery plan to ensure the time limit
Assist users to handle the acceptance procedures
Perfect after-sales service
During the warranty period, problems will only be replaced and not repaired
Never put a problem on the back of your head
Service hotline 7x24 hours service
Solemn promise
1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.
2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.
3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.
4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.
5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.
6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.
7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.
email:1583694102@qq.com
wang@kongjiangauto.com